ACR PLB-410 RLS

ACR ResQLink 410 RLS Personal Locator Beacon User Manual

Introducció

The ACR ResQLink 410 RLS is a compact, buoyant personal locator beacon designed to alert search and rescue services in emergency situations. It features Return Link Service (RLS), GPS, Galileo GNSS, and MEOSAR compatibility for global coverage and accurate positioning. This manual provides essential information for the proper setup, operation, and maintenance of your ResQLink 410 RLS.

ACR ResQLink 410 RLS Personal Locator Beacon
The ACR ResQLink 410 RLS Personal Locator Beacon, a compact device for emergency signaling.

Producte acabatview Vídeo

Aquest vídeo ofereix un finalview of the new ACR ResQLink RLS Personal Locator Beacons, highlighting their key features and benefits.

Configuració

Inscripció

Before initial use, it is mandatory to register your ACR ResQLink 410 RLS with the appropriate national authority (e.g., NOAA in the USA). Registration ensures that search and rescue services have access to your emergency contact information and vessel details, which is crucial for a timely and effective rescue. Failure to register may delay rescue efforts. Follow the instructions provided in the packaging or visit the manufacturer's website for detailed registration steps.

Battery Installation/Check

The ResQLink 410 RLS comes with two Lithium Metal batteries pre-installed. These batteries have a 5-year life. Regularly check the battery expiration date printed on the device. If the battery is nearing its expiration or has been activated, it must be replaced by an authorized service center to ensure proper functionality.

Initial Activation Test

It is recommended to perform a self-test upon receiving your beacon and periodically thereafter to ensure it is functioning correctly. Refer to the 'Self-Test Function' in the Operating Instructions section for detailed steps.

Activation Guide Video

This video demonstrates the activation process for ACR ResQlink 400 and 425 series PLBs, which is similar to the 410 RLS model.

Instruccions de funcionament

Activació d'emergència

  1. Deploy Antenna: Slide the antenna cover to expose and fully extend the antenna. Ensure it is positioned at a 90-degree angle to the device, pointing towards the sky.
  2. Activate Beacon: Press and hold the 'ON' button for approximately 2 seconds until the red LED light begins to flash and the strobe light activates. The device will immediately begin to acquire GPS coordinates.
  3. Confirm RLS: Once GPS is acquired, the red LED light will turn green, indicating that your distress message has been sent and Return Link Service (RLS) confirmation is being processed.
  4. Mantenir la posició: Keep the beacon in an open area with a clear view of the sky until rescue personnel arrive. Do not turn it off until you have been rescued.
ACR ResQLink 410 RLS in hand
The ACR ResQLink 410 RLS held in hand, ready for deployment.

Desactivació

To deactivate the beacon, press and hold the power button for 3 seconds. The device will power off. Once deactivated, retract the antenna and secure the cover.

Funció d'autotest

The self-test function allows you to verify the beacon's operational status without sending a distress signal. To perform a self-test, ensure the antenna is deployed, then press the 'TEST' button (often indicated by a 'T' or checkmark) for 1 second. The display will show 'TEST' and then 'GPS' as it attempts to acquire a signal. A successful test will typically show 'PASS' or a green light, indicating the beacon is ready for use.

Manteniment

To ensure your ResQLink 410 RLS remains in optimal working condition, perform regular checks:

Resolució de problemes

No GPS Signal Acquisition

Ensure the beacon has a clear, unobstructed view of the sky. Obstructions like dense foliage, buildings, or being inside a vessel can prevent GPS signal acquisition. Move to an open area if possible.

Beacon Not Activating

Verify that the antenna is fully deployed and the activation button is pressed and held for the specified duration (typically 2 seconds for activation). Check the battery status if the device fails to respond.

Falses Alarmes

If the beacon is accidentally activated, immediately deactivate it by pressing and holding the power button for 3 seconds. Contact your national search and rescue authority (e.g., NOAA) to report the false alarm and prevent unnecessary deployment of resources.

Especificacions

CaracterísticaDetall
Dimensions del producte4.52 x 2.03 x 1.49 polzades
Pes de l'article1 lliures
Número de model de l'articlePLB-410 RLS
BateriesNecessites 2 piles de metall de liti (incloses)
Tecnologies de connectivitatRF
GPSGPS habilitat
Característiques especialsServei d'enllaç de retorn
Entrada de la interfície humanaBotons
ColorNegre, groc
Què hi ha a la caixaBelt Clip, PFD Oral Inflation Tube Clip, Attachment Strap
FabricantACR Electronics
Data de primera disponibilitat14 de juny de 2022

Informació de la garantia

The ACR ResQLink 410 RLS typically comes with a manufacturer's warranty. For specific details regarding warranty coverage, duration, and claims procedures, please refer to the official warranty documentation included with your product or visit the ACR Electronics weblloc web. Conserveu el comprovant de compra per a finalitats de garantia.

Suport i contacte

For technical assistance, product inquiries, or to report an emergency beacon activation, please contact ACR Electronics customer support. You can find contact information on the official ACR Electronics weblloc.

ACR Electronics Official Weblloc: www.acrartex.com

Documents relacionats - PLB-410 RLS

Preview Guia d'instal·lació de l'ACR ResQLink PLB per a l'armilla salvavides Atlas 190 UML
Instruccions pas a pas per instal·lar una balisa de localització personal (PLB) ACR ResQLink a una armilla salvavides Atlas 190 UML, garantint un funcionament segur i correcte.
Preview Instruccions de muntatge AIS ACR ResQlink per a l'armilla salvavides Atlas 190 Hammar
Guia pas a pas per instal·lar una balisa de localització personal (PLB) AIS ACR ResQlink a una armilla salvavides Mustang Survival Atlas 190 Hammar, garantint una instal·lació correcta i segura per a situacions d'emergència.
Preview Instruccions per a ACR AISLink MOB a ELITE 190 PFD inflable
Guia pas a pas sobre com instal·lar un dispositiu ACR AISLink MOB a un PFD inflable ELITE 190, garantint un funcionament segur i correcte.
Preview ACR Kelowna Gas Stove Manual: Installation, Operation, and Maintenance
Comprehensive user and installation manual for the ACR Kelowna gas stove (Model 12H, G20 at 20mbar), covering setup, operation, technical specifications, cleaning, maintenance, troubleshooting, error codes, and warranty information.
Preview ACR RCL-300A Searchlight Mounting and Installation Guide
Comprehensive guide for mounting and installing the ACR RCL-300A searchlight system, including URC-300 Master Controller and URP-102 Point Pad, with detailed wiring instructions and features.
Preview ACR Electric SEREN Stove Installation and User Manual
Comprehensive installation and user manual for the ACR Electric SEREN stove range (SEREN-70, SEREN-130, SEREN-150), covering setup, operation, maintenance, troubleshooting, and warranty information.