SILENT KNIGHT DSC PTC1620U AC Transformer User Manual

Model: PTC1620U

1. Introducció

The SILENT KNIGHT DSC PTC1620U is an AC plug-in transformer designed to provide consistent power to compatible DSC Impassa Alarm Systems. This unit ensures the alarm system receives necessary operating power and facilitates the charging of its backup battery.

It is specifically intended for Impassa systems with integrated alarm communications that do not include a transformer as part of their standard package.

2. Informació de seguretat

  • PRECAUCIÓ: Risc de descàrrega elèctrica.
  • Aquest dispositiu està dissenyat per Només ús en lloc sec. Do not expose to moisture or liquids.
  • Ensure the power outlet is easily accessible for disconnection if needed.
  • Do not attempt to open or modify the transformer. There are no user-serviceable parts inside.
  • Disconnect power before making any connections to the alarm system.

3. Contingut del paquet

  • 1 x SILENT KNIGHT DSC PTC1620U AC Transformer

4. Configuració i instal·lació

Follow these steps to properly install your DSC PTC1620U AC Transformer:

  1. Identificar els punts de connexió: Locate the power input terminals on your DSC Impassa Alarm System. These are typically labeled for AC power input.
  2. Preparació del cablejat: Ensure the alarm system is powered off and disconnected from any other power sources before making connections.
  3. Connexió al sistema d'alarma: Connecteu el baix voltage wires from the transformer's terminal block to the corresponding AC input terminals on your DSC Impassa Alarm System. Ensure polarity is correct if specified by your alarm system's manual. The transformer features two screw terminals for connection.
  4. Connecteu-vos a la presa de corrent: Insert the transformer's two-prong plug into a standard 120VAC wall outlet. Ensure the outlet is easily accessible and not controlled by a switch.
  5. Verifica l'alimentació: Once connected and plugged in, power on your alarm system and verify that it is receiving power and operating correctly.
DSC PTC1620U AC Transformer

Figure 1: The DSC PTC1620U AC Transformer, showing its two-prong plug for wall outlets and the low-voltage screw terminals for connection to the alarm system. The label indicates input 120VAC 60Hz 0.43A and output 16.5VAC 20VA, and UL listing for dry locations.

5. Funcionament

The DSC PTC1620U AC Transformer operates automatically once properly installed and connected to a live 120VAC outlet. It continuously supplies 16.5 Volts of AC power at 20 VA to the connected DSC Impassa Alarm System.

The transformer's primary function is to power the alarm system and maintain the charge of its backup battery, ensuring continuous operation even during power fluctuations or outages (when the backup battery is fully charged and functional).

6. Manteniment

  • Neteja: Keep the transformer clean and free from dust. Use a dry cloth for cleaning. Do not use liquid cleaners.
  • Inspecció: Periodically inspect the transformer and its wiring for any signs of damage, such as frayed cables, cracks in the casing, or discoloration. If damage is observed, discontinue use and replace the unit.
  • Medi ambient: Ensure the transformer is always used in a dry indoor location, away from direct sunlight, heat sources, and moisture.

7. Solució De Problemes

ProblemaCausa possibleSolució
Alarm system not receiving power.
  • No hi ha corrent a la presa de corrent.
  • Transformer not fully plugged in.
  • Loose or incorrect wiring to alarm system.
  • Transformador defectuós.
  • Prova la presa de corrent amb un altre dispositiu.
  • Ensure the transformer is securely plugged into the outlet.
  • Verify all wiring connections are secure and correct according to the alarm system's manual.
  • If all other steps fail, the transformer may be faulty and require replacement.
Transformer feels warm.Funcionament normal.A slight warmth during operation is normal. If the transformer becomes excessively hot to the touch or emits a burning smell, disconnect it immediately and replace it.

8. Especificacions

Número de modelPTC1620U
MarcaCAVALLER EN SILENCIO
Entrada Voltage120 VCA, 60 Hz, 0.43 A
Vol. De sortidatage16.5 VAC, 20 VA
Dimensions (aprox.)4 x 3 x 3 polzades
Pes (aprox.)1.04 lliures
ComplimentUL Listed (Class 2 Transformer)
UPC808236716098

9. Garantia i Suport

For warranty information and technical support, please refer to the documentation provided with your DSC Impassa Alarm System or contact the manufacturer directly. Specific warranty terms may vary.

Documents relacionats - PTC1620U

Preview Knight Z40 Final Exit Switch - Technical Specification and Shunt Selection
Detailed technical specification and shunt selection guide for the Knight Z40 Final Exit Switch, including installation, operation, and wiring details for EOL alarm systems.
Preview Scheppach HDA-14 Heavy Duty Air Filter User Manual
This user manual provides comprehensive instructions for the Scheppach HDA-14 Heavy Duty Air Filter, covering setup, operation, maintenance, and safety guidelines. Learn how to effectively use and care for your air filtration system.
Preview Guia d'instal·lació de Corel Painter 2015: instal·lació i personalització silencioses
Apreneu a realitzar instal·lacions silencioses de Corel Painter 2015, personalitzar les rutes d'instal·lació i gestionar els números de sèrie i les opcions de registre amb aquesta guia d'instal·lació completa.
Preview be quiet! Silent Base 802 User Manual
User manual for the be quiet! Silent Base 802 PC case, detailing its features, specifications, and installation guides.
Preview Guia d'inici ràpid del ratolí sense fil multimode Rapoo
Una guia d'inici ràpid per al ratolí sense fil multimode Rapoo, que cobreix la configuració, l'emparellament i el funcionament en diversos dispositius mitjançant Bluetooth i 2.4 GHz.
Preview Guia de l'usuari del ratolí sense fil - CITLLA L570
Guia completa del ratolí sense fil Bluetooth CITLLA L570, que cobreix la configuració, les funcions i la resolució de problemes per a diversos sistemes operatius, com ara Windows i macOS.