1. Introducció
The Jasco V-630 iRM UV-Vis Spectrophotometer is a high-performance analytical instrument designed for precise absorbance and transmittance measurements across the ultraviolet and visible spectrum (190-1100nm). Featuring an intuitive touch panel interface, this device is suitable for a wide range of applications in research, quality control, and educational settings.
Les característiques clau inclouen:
- Jasco V-630 iRM UV-Vis Spectrophotometer with Touch Panel 190-1100nm
- Manufacturer Model Number: V-630
- Manufacturer Name: Jasco

Figura 1.1: Frontal view of the Jasco V-630 iRM UV-Vis Spectrophotometer, showing the main unit with the sample compartment on the left and the integrated touch panel on the right.
2. Configuració
2.1 Desembalatge i inspecció
Carefully remove the spectrophotometer and all accessories from the packaging. Inspect for any signs of damage during transit. Retain all packaging materials for future transport or storage.
2.2 Col·locació
Place the instrument on a stable, level surface away from direct sunlight, excessive vibration, and strong magnetic fields. Ensure adequate ventilation around the unit to prevent overheating. Maintain a clear space of at least 10 cm around all sides.
2.3 Connexió d'alimentació
Connect the provided power cord to the instrument's power inlet and then to a grounded electrical outlet. Ensure the power supply matches the instrument's voltage requisits.
2.4 Engegada inicial
Press the power button located on the front panel. The system will initiate a self-test and calibration sequence. Allow the instrument to warm up for at least 15-30 minutes for optimal performance and stability.

Figura 2.1: Primer pla view of the Jasco V-630 iRM Spectrophotometer's side panel, showing the product label with model number and manufacturer information.
3. Instruccions de funcionament
3.1 Touch Panel Interface
The V-630 iRM features an integrated touch panel for all operational controls and data display. Navigate through menus by tapping the corresponding icons or text. Use the stylus provided for precise input if necessary.
3.2 Sample Preparació
Prepara el teu samples according to standard laboratory procedures. Ensure cuvettes are clean, free of scratches, and compatible with the desired wavelength range. For UV measurements, quartz cuvettes are recommended.
3.3 Measurement Procedures
- From the main menu, select the desired measurement mode (e.g., Absorbance, Transmittance, Quantitative Analysis).
- Follow the on-screen prompts to set parameters such as wavelength range, scan speed, and data interval.
- Insert a blank (reference) cuvette into the sample compartment and perform a baseline correction or zeroing as prompted.
- Replace the blank with your sample cuvette.
- Initiate the measurement. The results will be displayed on the touch panel.
3.4 Data Analysis and Export
The instrument allows for basic on-board data analysis. Data can typically be saved to internal memory or exported via USB or network connection (if available) for further analysis on external software.

Figure 3.1: Composite image showing the Jasco V-630 iRM's touch panel interface with various menu options and a view del sample compartment designed for cuvettes.
4. Manteniment
4.1 Neteja
Regularly clean the exterior of the instrument with a soft, damp cloth. For the touch panel, use a screen-specific cleaner and a microfiber cloth. Avoid abrasive cleaners or solvents. Keep the sample compartment clean and free of spills.
4.2 Calibració
Periodic calibration using certified reference materials is recommended to ensure measurement accuracy. Refer to the instrument's on-screen calibration menu or consult a qualified service technician for advanced calibration procedures.
4.3 Emmagatzematge
When not in use for extended periods, power off the instrument and cover it with a dust cover to protect it from environmental contaminants. Store in a dry, temperature-controlled environment.
5. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| Instrument does not power on | Power cord disconnected; Power outlet fault | Comproveu la connexió del cable d'alimentació; proveu una presa de corrent diferent |
| Measurement errors / Inconsistent readings | Dirty cuvettes; Incorrect sample preparation; Lamp a prop del final de la vida | Clean cuvettes thoroughly; Re-prepare samples; Contact service for lamp substitució |
| El panell tàctil no respon | Software glitch; Screen calibration issue | Restart the instrument; Recalibrate touch screen if option is available |
For issues not listed here or if solutions do not resolve the problem, please contact Jasco customer support.
6. Especificacions
- Fabricant: Jasco
- Número de peça: V-630
- ASIN: B0B7X37887
- Primera data disponible a Amazon.co.jp: 27 de juliol de 2022
- Range de longitud d'ona: 190-1100 nm
- Interfície: Panell tàctil
7. Garantia i Suport
This product is covered by the manufacturer's standard warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or contact Jasco directly. Support for the Jasco V-630 iRM Spectrophotometer is available through authorized service centers and the manufacturer's customer service channels.
For technical assistance, service requests, or to inquire about replacement parts, please visit the official Jasco weblloc web o poseu-vos en contacte amb la seva línia d'atenció al client.