Jasco V-630

Manual d'usuari de l'espectrofotòmetre UV-Vis Jasco V-630 iRM

Model: V-630 | Wavelength Range: 190-1100nm

1. Introducció

The Jasco V-630 iRM UV-Vis Spectrophotometer is a high-performance analytical instrument designed for precise absorbance and transmittance measurements across the ultraviolet and visible spectrum (190-1100nm). Featuring an intuitive touch panel interface, this device is suitable for a wide range of applications in research, quality control, and educational settings.

Les característiques clau inclouen:

Jasco V-630 iRM UV-Vis Spectrophotometer front view

Figura 1.1: Frontal view of the Jasco V-630 iRM UV-Vis Spectrophotometer, showing the main unit with the sample compartment on the left and the integrated touch panel on the right.

2. Configuració

2.1 Desembalatge i inspecció

Carefully remove the spectrophotometer and all accessories from the packaging. Inspect for any signs of damage during transit. Retain all packaging materials for future transport or storage.

2.2 Col·locació

Place the instrument on a stable, level surface away from direct sunlight, excessive vibration, and strong magnetic fields. Ensure adequate ventilation around the unit to prevent overheating. Maintain a clear space of at least 10 cm around all sides.

2.3 Connexió d'alimentació

Connect the provided power cord to the instrument's power inlet and then to a grounded electrical outlet. Ensure the power supply matches the instrument's voltage requisits.

2.4 Engegada inicial

Press the power button located on the front panel. The system will initiate a self-test and calibration sequence. Allow the instrument to warm up for at least 15-30 minutes for optimal performance and stability.

Jasco V-630 iRM Spectrophotometer warranty label

Figura 2.1: Primer pla view of the Jasco V-630 iRM Spectrophotometer's side panel, showing the product label with model number and manufacturer information.

3. Instruccions de funcionament

3.1 Touch Panel Interface

The V-630 iRM features an integrated touch panel for all operational controls and data display. Navigate through menus by tapping the corresponding icons or text. Use the stylus provided for precise input if necessary.

3.2 Sample Preparació

Prepara el teu samples according to standard laboratory procedures. Ensure cuvettes are clean, free of scratches, and compatible with the desired wavelength range. For UV measurements, quartz cuvettes are recommended.

3.3 Measurement Procedures

  1. From the main menu, select the desired measurement mode (e.g., Absorbance, Transmittance, Quantitative Analysis).
  2. Follow the on-screen prompts to set parameters such as wavelength range, scan speed, and data interval.
  3. Insert a blank (reference) cuvette into the sample compartment and perform a baseline correction or zeroing as prompted.
  4. Replace the blank with your sample cuvette.
  5. Initiate the measurement. The results will be displayed on the touch panel.

3.4 Data Analysis and Export

The instrument allows for basic on-board data analysis. Data can typically be saved to internal memory or exported via USB or network connection (if available) for further analysis on external software.

Jasco V-630 iRM Spectrophotometer touch panel interface and sampel compartiment

Figure 3.1: Composite image showing the Jasco V-630 iRM's touch panel interface with various menu options and a view del sample compartment designed for cuvettes.

4. Manteniment

4.1 Neteja

Regularly clean the exterior of the instrument with a soft, damp cloth. For the touch panel, use a screen-specific cleaner and a microfiber cloth. Avoid abrasive cleaners or solvents. Keep the sample compartment clean and free of spills.

4.2 Calibració

Periodic calibration using certified reference materials is recommended to ensure measurement accuracy. Refer to the instrument's on-screen calibration menu or consult a qualified service technician for advanced calibration procedures.

4.3 Emmagatzematge

When not in use for extended periods, power off the instrument and cover it with a dust cover to protect it from environmental contaminants. Store in a dry, temperature-controlled environment.

5. Solució De Problemes

ProblemaCausa possibleSolució
Instrument does not power onPower cord disconnected; Power outlet faultComproveu la connexió del cable d'alimentació; proveu una presa de corrent diferent
Measurement errors / Inconsistent readingsDirty cuvettes; Incorrect sample preparation; Lamp a prop del final de la vidaClean cuvettes thoroughly; Re-prepare samples; Contact service for lamp substitució
El panell tàctil no responSoftware glitch; Screen calibration issueRestart the instrument; Recalibrate touch screen if option is available

For issues not listed here or if solutions do not resolve the problem, please contact Jasco customer support.

6. Especificacions

7. Garantia i Suport

This product is covered by the manufacturer's standard warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or contact Jasco directly. Support for the Jasco V-630 iRM Spectrophotometer is available through authorized service centers and the manufacturer's customer service channels.

For technical assistance, service requests, or to inquire about replacement parts, please visit the official Jasco weblloc web o poseu-vos en contacte amb la seva línia d'atenció al client.

Documents relacionats - V-630

Preview Espectrofotòmetres JASCO V-700 Sèrie UV-Visible/NIR: Rendiment, Innovació, Fiabilitat
Exploreu els espectrofotòmetres UV-Visible/NIR de la sèrie JASCO V-700, que ofereixen caracterització espectral avançada, estudis termodinàmics i mesures quantitatives per a la investigació biomèdica i de materials. Compten amb cinc models amb amplis rangs de longitud d'ona i dissenys compactes.
Preview JASCO Pharmaceutical Solutions Book: Advanced Spectroscopy and Chromatography Instruments
Discover JASCO's comprehensive portfolio of advanced spectroscopy and chromatography instruments, featuring detailed applications and solutions specifically designed for the pharmaceutical industry. This volume highlights the company's expertise in scientific analytical instrumentation.
Preview Garantia limitada de Jasco Products Company: 90 dies
Aquest document descriu la garantia limitada de 90 dies per a Jasco Products Company LLC. Detalla els termes i condicions de les reclamacions de garantia, les exclusions, les limitacions i els drets del consumidor.
Preview Garantia limitada de Jasco Products Company: 2 anys
Aquest document descriu la garantia limitada de 2 anys que ofereix Jasco Products Company LLC per als seus productes. Detalla els termes, les condicions, les limitacions i els procediments per presentar una sol·licitud de garantia, i emfatitza que la garantia cobreix els defectes de fabricació i no és transferible.
Preview Interruptor intel·ligent de paret Jasco 46563 Z-Wave: QuickFit i SimpleWire
Explore the Jasco 46563 Z-Wave In-Wall Smart Toggle Switch, designed for seamless smart home integration. Featuring QuickFit and SimpleWire technologies for simplified installation, this switch enables up to 6-way control and works with popular voice assistants like Amazon Alexa and Google Assistant. Expand your home automation capabilities with this versatile device.
Preview Sensor intel·ligent de fuites d'aigua Jasco Pro Series (81018): guia d'instal·lació i configuració
Guia completa per a la instal·lació i configuració del sensor intel·ligent de fuites d'aigua Jasco Pro Series (model 81018, ZWN6310). Apreneu a connectar-vos a xarxes Z-Wave, solucionar problemes i utilitzar les seves funcions per a la domòtica i la detecció de fuites d'aigua.