York S1-3L01-230

York Control, Fan & Limit Snap Disc 230 Deg Instruction Manual

Marca: York | Model: S1-3L01-230

1. Producte acabatview

The York Control, Fan & Limit Snap Disc 230 Deg is a crucial component designed for commercial HVAC units. This genuine OEM (Original Equipment Manufacturer) part ensures the safe and efficient operation of your equipment by providing precise temperature control and limit functions. It is engineered to meet original part specifications, guaranteeing exact fitment and reliable performance as a direct replacement.

York Control, Fan & Limit Snap Disc 230 Deg

Figure 1: York Control, Fan & Limit Snap Disc 230 Deg. This image displays the snap disc component, featuring its metal mounting plate, electrical terminals, and the yellow label indicating model and temperature specifications.

2. Característiques clau

  • Peça original del fabricant (OEM): Ensures authenticity and compatibility with York HVAC systems.
  • Seguretat i fiabilitat: Designed to maintain high safety standards and consistent performance.
  • Ajustament exacte: Engineered to match original specifications for seamless replacement.
  • Control de temperatura: Functions as a fan and limit control, activating or deactivating based on temperature thresholds, specifically 230 degrees.

3. Què hi ha a la caixa

En obrir l'envàs, trobareu els següents components:

  • One (1) York Control, Fan & Limit Snap Disc 230 Deg (Model: S1-3L01-230)

4. Especificacions tècniques

AtributDetall
Dimensions del producte2 x 2 x 2 polzades
Pes de l'article0.63 unces
Número de modelS1-3L01-230
FabricantYork
Qualificació de temperatura230 Degrees Fahrenheit (as indicated by "230 Deg" in product title)
Tipus de partControl, Fan & Limit Snap Disc

5. Configuració i instal·lació

Informació important de seguretat: Installation of this component should only be performed by a qualified HVAC technician. Ensure that the power supply to the HVAC unit is completely disconnected before beginning any installation or maintenance work. Failure to do so can result in serious injury or damage to the equipment.

  1. Desconnexió d'alimentació: Locate the main power switch for your HVAC system and turn it OFF. Verify that no power is reaching the unit using a voltage provador.
  2. Accedir al component: Open the access panel of your HVAC unit to locate the existing fan and limit control snap disc.
  3. Desconnecteu el cablejat: Carefully note the wiring connections to the old snap disc. It is recommended to take a photograph or draw a diagram of the connections before disconnecting. Disconnect all wires from the old component.
  4. Elimina el component antic: Unscrew or unclip the old snap disc from its mounting bracket.
  5. Instal·la un component nou: Position the new York Control, Fan & Limit Snap Disc (Model S1-3L01-230) into the mounting bracket. Secure it firmly using the appropriate screws or clips.
  6. Reconnectar el cablejat: Reconnect the wires to the new snap disc according to the diagram or photograph taken earlier. Ensure all connections are secure and properly insulated.
  7. Panell d'accés segur: Close and secure the HVAC unit's access panel.
  8. Restaura l'alimentació: Turn the main power switch for your HVAC system back ON.
  9. Prova de funcionament: Monitor the HVAC unit's operation to ensure the new snap disc is functioning correctly, activating the fan and limit controls as expected based on temperature.

6. Funcionament

The York Control, Fan & Limit Snap Disc is an automatic thermal switch designed to respond to temperature changes within the HVAC system. Its primary functions are:

  • Control del ventilador: The snap disc monitors the temperature in the furnace plenum or heat exchanger. When the temperature rises to a predetermined set point (e.g., for fan activation), the bimetallic disc "snaps" to close a circuit, turning on the furnace fan to distribute heated air.
  • Control de límit: If the temperature continues to rise beyond a safe operating limit (e.g., 230 degrees Fahrenheit), the snap disc will "snap" to open a circuit, shutting down the burner to prevent overheating and potential damage to the furnace. This acts as a critical safety mechanism.

The snap disc operates automatically and does not require manual intervention during normal system operation. Its design ensures reliable and precise temperature-based switching.

7. Manteniment

The York Control, Fan & Limit Snap Disc is a sealed component and generally requires no routine maintenance. However, periodic inspection of the component and its connections is recommended as part of a comprehensive HVAC system maintenance schedule.

  • Inspecció visual: During routine HVAC system checks, visually inspect the snap disc for any signs of physical damage, corrosion, or loose wiring connections.
  • Neteja: Ensure the area around the snap disc is free from dust, debris, or obstructions that could affect its temperature sensing capabilities.
  • Verificació professional: It is advisable to have a qualified HVAC technician inspect the snap disc's functionality and calibration during annual system servicing.

If any issues are observed, or if the HVAC system exhibits unusual fan or heating behavior, consult a qualified technician for diagnosis and potential replacement.

8. Solució De Problemes

This section provides guidance on common issues related to the fan and limit control. For complex problems, always consult a qualified HVAC technician.

ProblemaCausa possibleSolució
Furnace fan not turning onFaulty snap disc (fan control), clogged air filter, thermostat issue, motor problem.Check air filter. Verify thermostat settings. If other components are fine, the snap disc may need replacement. Consult a technician.
Furnace overheating / frequently shutting offFaulty snap disc (limit control), restricted airflow, dirty burners, oversized furnace.Ensure all vents are open. Check for obstructions in ductwork. Clean burners if accessible. If problem persists, the limit control may be faulty. Professional diagnosis is required.
El ventilador funciona contínuamentSnap disc contacts stuck closed, thermostat fan setting on "ON", short circuit in wiring.Check thermostat fan setting and set to "AUTO". If fan still runs, the snap disc may be faulty and require replacement. Inspect wiring for shorts.

Nota: Always disconnect power to the HVAC unit before attempting any inspection or repair.

9. Garantia i Suport

As a genuine OEM part, the York Control, Fan & Limit Snap Disc (Model S1-3L01-230) is typically covered by the manufacturer's standard warranty for replacement parts. Specific warranty terms and duration may vary. Please retain your proof of purchase for warranty claims.

Atenció al client:

For technical assistance, warranty inquiries, or to locate authorized service providers, please contact York customer support or visit their official website. Always refer to the official York documentation for the most accurate and up-to-date support information.

York Official Weblloc: www.york.com (Nota: Això és un marcador de posició URL. Please refer to official product documentation for the correct support contact information.)

Documents relacionats - S1-3L01-230

Preview York Affinity Series Central Dehumidifiers: Whole-Home Humidity Control & Air Quality
Discover the York Affinity Series Central Dehumidifiers, designed to enhance your home's indoor air quality by effectively managing humidity. Learn how these units provide whole-home comfort, protect against mold and allergens, prevent structural damage, and offer energy savings. Features include easy maintenance and a 5-year warranty. Explore sizing guidelines and installation options.
Preview Banyera independent YORK-Y409: Guia d'instal·lació, manteniment i seguretat
Guia completa per a la banyera independent YORK-Y409, que cobreix les característiques del producte, instruccions detallades d'instal·lació (amb i sense accés sota terra), consells de manteniment, procediments de neteja, eliminació de ratllades i avisos de seguretat importants. Inclou les dimensions del producte i informació sobre la garantia.
Preview YORK Chiller Materials Application and Chemicals Limit Guide for Various Water Qualities
A comprehensive guide from Johnson Controls detailing material application and chemical limits for YORK chillers across various water qualities, including potable, non-potable, treated sewage effluent (TSE), seawater, and brackish water. It provides essential safety guidelines and component recommendations for optimal chiller performance and longevity.
Preview YORK Champion Series D1NA/D2NA Single Package Gas/Electric Air Conditioner Installation Instructions
Comprehensive installation guide for YORK Champion Series D1NA and D2NA single package gas/electric air conditioners. Covers general information, inspection, parts, safety warnings, installation procedures, wiring, gas piping, maintenance, and troubleshooting for models D1NA018 through D1NA048 and D2NA060.
Preview Llista de peces dels forns de gas natural horitzontal/de flux descendent del 90% de la sèrie York PS9
Llista completa de peces i diagrames per als forns de gas natural horitzontal/de flux descendent del 90% de la sèrie York PS9, inclosos els números de model PS9B12N060DH11A, PS9B12N080DH11A, PS9C16N080DH11A, PS9C16N100DH11A, PS9C20N100DH11A i PS9D20N120DH11A. Inclou la identificació dels components i els números de peça.
Preview York DGAA & DGAH High Efficiency Gas Furnace: User, Maintenance, and Service Manual
Comprehensive guide for York DGAA and DGAH High Efficiency Sealed Combustion Gas Furnaces, covering safety, installation, operation, maintenance, troubleshooting, and parts.