1. Introducció
This manual provides essential information for the safe and effective operation of your Walfront BR-6 Nuclear Radiation Detector. Please read this manual thoroughly before using the device to ensure proper function and accurate readings. This device is designed for detecting Beta (β), Gamma (γ), and X-ray radiation.
2. Informació de seguretat
Always handle the device with care. Do not expose it to extreme temperatures, moisture, or strong impacts. This device is for informational detection purposes only and should not be used for medical diagnosis or as a substitute for professional safety equipment in high-risk environments. Ensure batteries are inserted correctly to prevent damage.
3. Característiques del producte
- Ampli rang de detecció: Capable of detecting Beta (β), Gamma (γ), and X-ray radiation.
- Alta precisió: Inherent error controlled within ±10%.
- Operació fàcil d'utilitzar: Simple and convenient steps for environmental radiation parameter detection.
- Múltiples modes de so: Features real particle sound, alarm sound, and mute options.
- Construcció duradora: Made from high-quality ABS material for impact and scratch resistance.
- Esborra la pantalla: Large TFT screen for real-time data monitoring, precise mean data, and intuitive trend graphs.
- Disseny portàtil: Small size for easy carrying and inspection.

Image: The Walfront BR-6 Nuclear Radiation Detector with a list of its key features, including nuclear radiation detection, radioactive detector, βγx ray trend graph, particle sound, alarm sound, and power supply options.
4. Contingut del paquet
En obrir el paquet, comproveu que tots els elements hi siguin presents i que no estiguin danyats:
- 1 x Walfront BR-6 Nuclear Radiation Detector
- 1 x Manual d'usuari (aquest document)
Note: 2 x 1.5V AA batteries and a USB cable are not included and must be purchased separately.
5. Producte acabatview
Familiarize yourself with the components of your Walfront BR-6 detector:

Image: A detailed diagram of the Walfront BR-6 detector, labeling its parts including the large screen TFT, ABS shell, intuitive trend graphs, start key, ordinary selection key, power button, real-time monitoring of data, precise mean data, side USB supply port, backlight, and off key.
6. Configuració
6.1 Instal·lació de la bateria
- Localitzeu la tapa del compartiment de la bateria a la part posterior del dispositiu.
- Feu lliscar la coberta oberta.
- Insert two (2) 1.5V AA batteries, ensuring correct polarity (+/-).
- Tanqueu bé la tapa del compartiment de la bateria.

Imatge: La part posterior view of the Walfront BR-6 Nuclear Radiation Detector, showing the battery compartment cover and product label with model number BR-6.
6.2 Encès
Premeu el botó ON button located on the front panel to power on the device. The LCD screen will illuminate and display the current readings.
7. Instruccions de funcionament
7.1 Automatic Detection
Once powered on, the device automatically begins detecting radiation. The main display will show the real-time radiation dose rate in µSv/h. The trend graph provides a visual representation of radiation level changes over time.

Image: A close-up of the Walfront BR-6 detector's LCD screen, showing a digital reading of 00.23 µSv/h, an average reading (AVG), and a trend graph (TREND) indicating radiation levels over time.
7.2 Adjusting Alarm Threshold
The device allows you to set an alarm threshold. If the detected radiation level exceeds this threshold, an audible alarm will sound (if not muted).
- Premeu el botó Ordinary selection key (usually represented by a speaker icon or similar) to cycle through sound modes or alarm settings.
- Available alarm thresholds are typically 0.5, 1.0, 2.0, and 5.0 µSv/h. Select the desired threshold.
7.3 Configuració de so
The device supports different sound modes:
- Real Particle Sound: Emits a click sound for each detected radiation particle.
- So d'alarma: Sounds when the radiation level exceeds the set threshold.
- Silenciar: Disables all sounds.
Utilitza el Ordinary selection key to switch between these sound modes.
Control de retroiluminació 7.4
Premeu el botó Llum de fons button (usually represented by a light bulb icon) to turn the screen backlight on or off, improving visibility in different lighting conditions.
7.5 Apagat
Premeu el botó OFF button to turn off the device when not in use.
8. Aplicacions
The Walfront BR-6 Nuclear Radiation Detector is suitable for a variety of detection scenarios:
- Home decoration environment detection
- Distance detection after ion implantation
- Radiological protection detection
- Airport security inspection machine detection
- Overseas shopping goods residue detection (e.g., Japanese goods)
- Maternity and baby products radioactivity detection
- Jewelry, stone, and jade articles radioactivity detection
- Cosmetics radiation residue detection

Image: The Walfront BR-6 detector centrally placed, surrounded by images depicting various application scenarios such as signal towers, factories, medical facilities, reflective substances, and microwave ovens, illustrating its wide detection capabilities.
9. Manteniment
To ensure the longevity and accuracy of your device, follow these maintenance guidelines:
- Keep the device clean and dry. Use a soft, dry cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
- Avoid exposing the device to direct sunlight, high temperatures, or high humidity for extended periods.
- When storing the device for a long time, remove the batteries to prevent leakage and damage.
- Do not attempt to open or repair the device yourself, as this will void the warranty and may cause damage or injury.
10. Solució De Problemes
If you encounter issues with your Walfront BR-6 detector, try the following steps:
- El dispositiu no s'encén: Check if the batteries are inserted correctly with the right polarity. Replace with fresh AA batteries. Ensure the ON button is pressed firmly.
- No readings or erratic readings: Ensure the device is in an environment where radiation is expected. If in a known radiation source, and still no reading, the sensor might be obstructed or damaged.
- L'alarma no sona: Check the sound settings to ensure the device is not in mute mode and the alarm threshold is set appropriately.
- Problemes de pantalla: If the screen is dim or flickering, replace the batteries.
Si els problemes persisteixen després d'intentar aquests passos de resolució de problemes, poseu-vos en contacte amb l'atenció al client.
11. Especificacions
| Model | BR-6 |
| Material | ABS |
| Sensor | Energy compensation type tube |
| Tipus de detecció | Beta (β), Gamma (γ), X-ray |
| Inherent Error | ±10% |
| Sensibilitat | 80cpm µSv (Co 60) |
| Interval de mesura | 00.00~99.99 µSv/h |
| Sound Source Type | Real particle sound, alarm sound, mute |
| Llindars d'alarma | 0.5, 1.0, 2.0, 5.0 µSv/h |
| Bateria | 2 piles AA de 1.5 V (no incloses) |
| Pes de l'article | 6 unces |
| Dimensions del paquet | 6.89 x 3.94 x 2.24 polzades |
| Número de model de l'article | WALFRONT910x5ocs8i |
12. Garantia i Suport
For warranty information or technical support, please refer to the purchase documentation or contact the seller directly. Keep your proof of purchase for any warranty claims.