Vitalograph 40353

Vitalograph COPD-6 Screener BT User Manual

Model: 40353

1. Introducció

This manual provides essential information for the safe and effective operation of the Vitalograph COPD-6 Screener BT. The Vitalograph COPD-6 is an electronic COPD screening device designed to ascertain the obstruction index and the FEV1/FEV6 ratio, thereby assisting in the detection of potential COPD diseases. It identifies individuals at risk of COPD at the pre-symptomatic stage and screens out those whose FEV1 is normal.

Si us plau, llegiu aquest manual detingudament abans d'utilitzar el dispositiu i conserveu-lo per a futures consultes.

Vitalograph COPD-6 Screener BT device, front view

Imatge 1: Frontal view of the Vitalograph COPD-6 Screener BT device.

2. Informació important de seguretat

Always adhere to the following safety precautions to ensure proper operation and prevent injury or damage to the device.

3. Components del dispositiu

Familiarize yourself with the main parts of your Vitalograph COPD-6 Screener BT.

Vitalograph COPD-6 Screener BT, top-down view

Imatge 2: De dalt a baix view showing the mouthpiece and display.

Vitalograph COPD-6 Screener BT, side view

Imatge 3: Lateral view of the device, highlighting its ergonomic design.

Vitalograph COPD-6 Screener BT with mouthpiece attached

Image 4: Device with a disposable mouthpiece attached for use.

Vitalograph COPD-6 Screener BT with large mouthpiece attached

Image 5: Device with a larger, alternative mouthpiece attached.

4. Configuració

4.1. Instal·lació de la bateria

  1. Localitzeu el compartiment de la bateria a la part posterior del dispositiu.
  2. Obriu la coberta del compartiment.
  3. Introduïu 2 piles AAA, assegurant-vos de la polaritat correcta (+/-) tal com s'indica a l'interior del compartiment.
  4. Tanqueu bé la tapa del compartiment de la bateria.

4.2. Fixació de la boquilla

  1. Select a clean, disposable mouthpiece.
  2. Align the mouthpiece with the opening on the device.
  3. Gently push the mouthpiece onto the device until it is firmly seated.

4.3. Initial Power On and Bluetooth Pairing

  1. Premeu el botó d'engegada per encendre el dispositiu.
  2. The device will display initial setup options or be ready for use.
  3. To pair with a computer or mobile device, ensure Bluetooth is enabled on both the COPD-6 Screener BT and the receiving device.
  4. Open the Vitalograph Reports Software (included) on your computer or the Vitalograph app on your mobile device.
  5. Follow the on-screen instructions within the software/app to complete the pairing process. The Bluetooth indicator on the COPD-6 will confirm successful connection.

5. Instruccions de funcionament

5.1. Realització d'una prova

  1. Ensure the device is powered on and a clean mouthpiece is attached.
  2. Sit upright and relax.
  3. Take a deep breath, filling your lungs completely.
  4. Place your lips tightly around the mouthpiece, ensuring no air leaks.
  5. Exhale as hard and as fast as you can, emptying your lungs completely. Continue exhaling for at least 6 seconds.
  6. The device will display the FEV1, FEV6, ratio, percent predicted, obstructive index, COPD classification, and lung age.
  7. Repeat the test as necessary, typically three times, to ensure consistent and accurate readings.

5.2. Interpretació de resultats

The device displays key spirometry parameters. The GOLD COPD classification (Stage I – IV) is shown to help recognize the need for a change in the patient’s management plan. Results are automatically sent to the paired software/app after each blow for detailed reporting and analysis.

6. Manteniment i cura

6.1. Neteja del dispositiu

6.2. Substitució de la bateria

When the battery indicator appears on the display, replace the batteries as described in the "Battery Installation" section (4.1). Always use new AAA alkaline batteries.

6.3. Emmagatzematge

Store the device in its carry pouch in a cool, dry place, away from direct sunlight and extreme temperatures.

7. Solució De Problemes

ProblemaCausa possibleSolució
El dispositiu no s'encén.Piles gastades o incorrectament inserides.Canvieu les piles, assegurant-vos de la polaritat correcta.
La connexió Bluetooth falla.Bluetooth is off on one of the devices; device is out of range; pairing issue.Ensure Bluetooth is on for both devices. Move devices closer. Re-attempt pairing via software/app.
Lectures inconsistents.Improper testing technique; mouthpiece not sealed properly.Review "Performing a Test" section (5.1). Ensure a tight seal around the mouthpiece.
La pantalla està en blanc o congelada.Software error; low battery.Remove and reinsert batteries to reset. If problem persists, contact support.

8. Especificacions

ParàmetreDetall
Nom del modelVitalograph COPD-6 Screener BT
Número de model40353
Dimensions14.5 x 9 x 16.5 cm
Pes140 g (0.14 kg)
Font d'alimentació2 x AAA Alkaline batteries (included)
ConnectivitatBluetooth
MaterialPlàstic
Sistema de mesuramètrica
IndicacionsCOPD screening

9. Garantia i Suport

9.1. Informació de la garantia

Vitalograph products are manufactured to high standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Vitalograph weblloc.

9.2. Atenció al client

For technical assistance, troubleshooting not covered in this manual, or service inquiries, please contact Vitalograph customer support. Contact details can typically be found on the Vitalograph weblloc web o a l'embalatge del producte.

Weblloc: www.vitalograph.co.uk