1. Introducció
This manual provides detailed instructions for the installation, operation, and maintenance of the GATEXPERT GT1300L Automatic Sliding Gate Operator Kit. This system is designed to automate sliding gates weighing up to 1300 lbs and measuring up to 40 feet in length, enhancing convenience and security for residential and light commercial applications.
Key features include a soft start and slow stop function for extended motor life, remote control operation, an infrared photocell for safety, and an adjustable automatic close function.
2. Contingut del paquet
Verifiqueu que tots els components que s'enumeren a continuació siguin presents al vostre kit:

Acabatview of the GATEXPERT GT1300L Automatic Sliding Gate Operator Kit, showing the main operator unit, two remote controls, infrared photocell sensors, drive chain, warning sign, and installation hardware.
- GATEXPERT GT1300L Gate Operator Unit
- Mounting Base/Bracket
- Drive Chain (20 feet, adjustable length)
- Two Remote Controls (Transmitters)
- Infrared Photocell Sensor Set
- Senyal d'advertència
- Emergency Release Keys
- Installation Hardware (bolts, nuts, chain connectors, etc.)
- Manual d'usuari (aquest document)
3. Informació de seguretat
ADVERTÈNCIA: Si no es segueixen aquestes instruccions de seguretat, es poden produir lesions greus o la mort.
- Read this entire manual carefully before installation and operation.
- Professional installation is recommended. Ensure all local electrical codes and safety standards are met.
- Keep the gate area clear of persons and objects while the gate is in motion.
- Do not allow children to operate the gate or play near the gate area.
- Ensure the infrared photocell is correctly installed and functioning to prevent the gate from closing on obstructions.
- In case of power failure, use the emergency release key to manually operate the gate.
- Disconnect power to the gate operator before performing any maintenance or repairs.

Illustrations of typical applications for the GATEXPERT GT1300L sliding gate operator, including residential driveways, courtyards, and farm entrances.
4. Especificacions
| Especificació | Valor |
|---|---|
| Número de model | GT1300L |
| Pes màxim de la porta | 1300 lliures (590 kg) |
| Longitud màxima de la porta | 40 peus (12 metres) |
| Pes de l'article | 35.9 lliures (16.3 kg) |
| Dimensions del producte | 11.8 x 9.1 x 19.3 polzades (30 x 23 x 49 cm) |
| Fabricant | GATEXPERT |
| Color | Negre |
| Característiques de control | Soft Start/Stop, Auto-Close, Infrared Photocell, Remote Control |
5. Configuració i instal·lació
5.1 Comprovació prèvia a la instal·lació
- Ensure the gate moves freely and smoothly by hand.
- Verify the ground surface where the operator will be mounted is level and stable.
- Confirm a suitable power source is available near the installation site.
5.2 Muntatge de l'operador
Securely mount the GATEXPERT GT1300L operator unit on its provided base/bracket next to the gate. The operator should be positioned so that the drive sprocket aligns correctly with the gate's chain path.

Davant view of the GATEXPERT GT1300L gate operator mounted on its base, featuring the manual release key access.

posterior view of the GATEXPERT GT1300L gate operator mounted on its base.
5.3 Instal·lació de la cadena
Attach the provided drive chain to the gate using the appropriate brackets and connectors. Route the chain around the operator's drive sprocket. Ensure the chain is taut but not overly tight, allowing for smooth movement without excessive strain on the motor.
5.4 Cablejat
Connect the power supply, infrared photocell sensors, and any other accessories to the control board inside the operator unit. Refer to the wiring diagram provided in the detailed installation guide for specific connections. Ensure all connections are secure and insulated.

Interna view of the GATEXPERT GT1300L control board, showing wiring terminals and electronic components for gate operation and safety features.
5.5 Photocell Installation
Mount the infrared photocell transmitter and receiver units on opposite sides of the gate opening. Ensure they are aligned perfectly so the infrared beam is unobstructed. The photocell acts as a safety device, preventing the gate from closing if an object breaks the beam.
6. Instruccions de funcionament
6.1 Funcionament del control remot
The remote controls operate in a single-button mode. Pressing any of the three main buttons will cycle the gate through OPEN / STOP / CLOSE / STOP. The fourth button is typically reserved for pedestrian mode, which opens the gate partially for foot traffic.
- Emparellament de comandaments a distància: If remotes are not pre-programmed, follow the instructions in the detailed guide to pair them with the operator's control board. The system supports up to 25 remotes.
- Substitució de la bateria: Substituïu les bateries del comandament a distància segons sigui necessari per garantir un funcionament fiable.
6.2 Automatic Close Function
The gate operator features an automatic close function. This can be configured to close the gate automatically after a set period of 12, 24, or 36 seconds. This function can also be disabled if not desired.
6.3 Infrared Photocell Safety
During the closing process, if the infrared beam of the photocell sensor is interrupted by an obstruction, the gate will immediately reverse and open to prevent damage or injury. Ensure the photocell lenses are kept clean and free from obstructions for optimal safety.
6.4 Alliberament manual
En cas d'una potènciatage or system malfunction, the gate can be operated manually. Insert the emergency release key into the lock on the operator unit and turn it to disengage the motor, allowing the gate to be pushed open or closed by hand.
7. Manteniment
Regular maintenance ensures the longevity and reliable operation of your gate operator system.
- Mensual: Inspect the gate's movement for any binding or resistance. Lubricate the gate rollers and hinges if necessary.
- Trimestral: Check the drive chain tension. Adjust if it is too loose or too tight. Inspect the chain for wear or damage.
- Bi-Annually: Clean the lenses of the infrared photocell sensors to ensure proper function. Check all electrical connections for tightness and corrosion.
- Anualment: Inspect the mounting hardware for the operator and gate for any signs of loosening or corrosion.
8. Solució De Problemes
Consulteu la taula següent per veure els problemes habituals i les seves possibles solucions:
| Problema | Causa possible | Solució |
|---|---|---|
| La porta no es mou | No power; Remote battery low; Manual release engaged; Obstruction | Check power supply; Replace remote battery; Disengage manual release; Remove obstruction |
| La porta s'atura inesperadament | Photocell obstructed; Motor overload; Limit switch issue | Clear photocell path; Check gate for resistance; Consult detailed manual for limit switch adjustment |
| El comandament a distància no funciona | Low battery; Not paired; Out of range | Replace battery; Re-pair remote; Operate within range |
| Gate opens but does not close | Photocell obstructed or misaligned; Auto-close disabled | Clear and align photocell; Enable auto-close function |
| Gate moves slowly or with difficulty | Gate friction; Low voltage; Motor issue | Lubricate gate components; Check power supply; Contact support if motor issue suspected |
9. Garantia i Suport
Specific warranty details are typically provided with your purchase documentation. Please refer to the warranty card or contact GATEXPERT directly for information regarding warranty coverage and support services.