1. Introducció i finalview
Thank you for choosing the Wipcool 2F0 Double Stage Vacuum Pump. This professional-grade vacuum pump is designed for efficient evacuation of air conditioning and refrigeration systems. Its robust construction and innovative features ensure reliable performance and ease of use.
The F series vacuum pumps are engineered for a superior user experience, featuring a built-in solenoid valve and an overhead vacuum meter as standard. The patented anti-dumping structure prevents oil leakage, even if the pump is accidentally tilted during operation or transport. The powerful and lightweight DC motor provides high efficiency, ensuring optimal performance even in lower ambient temperatures.

Figure 1: The Wipcool 2F0 Double Stage Vacuum Pump. This image displays the overall design of the pump, highlighting its compact and robust construction with green accents.
2. Instruccions de seguretat
Please read and understand all safety instructions before operating the Wipcool 2F0 vacuum pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.
- Seguretat elèctrica: Assegureu-vos que la font d'alimentació coincideixi amb el volum de la bombatage requirements. Do not operate the pump with a damaged power cord or plug. Always disconnect power before servicing.
- Equips de protecció individual (EPI): Always wear safety glasses and gloves when handling refrigerants and vacuum pump oil.
- Ventilació: Feu funcionar la bomba en una zona ben ventilada per evitar l'acumulació de vapors de refrigerant.
- Manipulació de refrigerants: This pump is suitable for R12, R22, R134a, and R410a. Always follow proper procedures for handling refrigerants to prevent environmental release.
- Nivell d'oli: Regularly check the oil level and ensure it is within the recommended range to prevent damage to the pump.
- Superfícies calentes: La bomba es pot escalfar durant el funcionament. Eviteu tocar superfícies calentes.
- Estabilitat: Col·loqueu la bomba sobre una superfície estable i anivellada per evitar que bolqui.
3. Característiques del producte
The Wipcool 2F0 vacuum pump incorporates several advanced features for enhanced performance and user convenience:
- Built-in Solenoid Valve: Prevents oil backflow into the system, protecting against contamination.
- Patented Anti-Dumping Structure: Designed to prevent oil leakage even if the pump is tilted, ensuring clean operation and transport.
- Overhead Vacuum Gauge: Provides clear and easy-to-read vacuum data without needing to bend down.
- Reinforced Aluminum Alloy Oil Tank: Offers effective heat dissipation and resistance to chemical corrosion.
- Oversized Sight Glass: Allows for easy monitoring of oil color and level.
- Powerful and Lightweight DC Motor: Ensures easy starting and high efficiency, even in lower ambient temperatures.
- Aplicació versàtil: Ideal for split systems, light duties in automotive, and small commercial applications.

Figure 2: Key features of the Wipcool 2F0 Vacuum Pump. This image illustrates the overhead vacuum gauge, anti-oil injection design, anti-dumping oil leakage design, and the built-in solenoid valve.
4. Configuració
4.1 Desembalatge
- Carefully remove the vacuum pump and all accessories from the packaging.
- Inspect the pump for any signs of damage during transit. If damaged, do not operate and contact your supplier.
- Conserveu l'embalatge per a futurs emmagatzematges o transports.
4.2 Afegir oli de la bomba de buit
The pump is shipped without oil. It is essential to fill the pump with high-quality vacuum pump oil before first use.
- Ensure the pump is on a level surface and powered off.
- Locate the oil fill cap (usually marked 'OIL' or with an oil symbol).
- Traieu el tap d'ompliment d'oli.
- Slowly pour vacuum pump oil into the oil reservoir until the oil level is between the 'MIN' and 'MAX' marks on the sight glass. Do not overfill.
- Torneu a col·locar el tap d'ompliment d'oli de manera segura.
4.3 Connexió d'alimentació
- Connect the power cord to the pump's power inlet.
- Connecteu el cable d'alimentació a una presa de corrent amb connexió a terra amb el volum correctetage.
5. Instruccions de funcionament
Follow these steps for safe and effective operation of your Wipcool 2F0 vacuum pump:
- Prepara el sistema: Ensure the refrigeration or AC system is properly isolated and depressurized before connecting the vacuum pump.
- Connecteu les mànegues: Connect appropriate vacuum hoses from the system's service ports to the inlet ports of the vacuum pump. Ensure all connections are tight to prevent leaks.
- Comprovar el nivell d'oli: Verify the oil level is correct in the sight glass.
- Inicieu la bomba: Turn the power switch to the 'ON' position. The pump will begin to operate.
- Monitor de buit: Observe the overhead vacuum gauge to monitor the evacuation process. Continue running the pump until the desired vacuum level is achieved.
- Isolate System: Once the target vacuum is reached, close the service valves on the system to isolate it from the pump.
- Aturar la bomba: Turn the power switch to the 'OFF' position.
- Desconnectar les mànegues: Carefully disconnect the vacuum hoses from the pump and the system.

Figure 3: The Wipcool 2F0 Vacuum Pump connected to an outdoor AC unit. This image demonstrates a typical setup for evacuating an air conditioning system.
6. Manteniment
Regular maintenance ensures the longevity and optimal performance of your Wipcool 2F0 vacuum pump.
6.1 Comprovació del nivell d'oli
- Check the oil level before each use. The oil should be between the 'MIN' and 'MAX' marks on the sight glass.
- Add oil if necessary, ensuring to use only high-quality vacuum pump oil.
6.2 Canvi d'oli
Change the vacuum pump oil regularly, especially if it appears cloudy, discolored, or contaminated. Contaminated oil reduces pump efficiency and can cause damage.
- Ensure the pump is warm (run for a few minutes) to allow oil to drain easily.
- Col·loqueu un recipient adequat sota el tap de drenatge d'oli.
- Remove the oil drain plug and the oil fill cap to allow air to enter and oil to drain completely.
- Un cop drenat, torneu a col·locar el tap de drenatge de l'oli de manera segura.
- Reompliu amb oli nou per a la bomba de buit tal com es descriu a la secció 4.2.
- Elimineu l'oli usat de manera responsable d'acord amb la normativa local.
6.3 Neteja
- Keep the exterior of the pump clean and free from dust and debris.
- Utilitzeu un suau, damp cloth for cleaning. Do not use harsh chemicals or solvents.
- Assegureu-vos que les obertures de ventilació estiguin clares i sense obstruccions.
7. Solució De Problemes
This section provides solutions to common issues you might encounter with your Wipcool 2F0 vacuum pump.
| Problema | Causa possible | Solució |
|---|---|---|
| La bomba no arrenca | Sense font d'alimentació Cable/endoll d'alimentació danyat Problema motor | Comproveu la connexió i la presa de corrent Inspeccioneu i substituïu si està danyat Contacta amb el centre de servei |
| Mal rendiment del buit | Low or contaminated oil Leaking connections/hoses System leak Components de la bomba desgastats | Check/change oil Tighten all connections, inspect hoses Check system for leaks Contacta amb el centre de servei |
| Excés de soroll/vibració | Baix nivell d'oli Pump not on level surface Problema mecànic intern | Check/add oil Place on stable, level surface Contacta amb el centre de servei |
| Fuga d'oli | Loose oil drain plug/fill cap Segells danyats Overfilled oil | Tighten plugs/caps Contacta amb el centre de servei Escorreu l'excés d'oli |
If you encounter a problem not listed here or if the suggested solutions do not resolve the issue, please contact customer support.
8. Especificacions
| Especificació | Detall |
|---|---|
| Número de model | 2F0 |
| Fabricant | Wipcool |
| Wattage | 230 watts |
| Pes de l'article | 4.7 kg |
| Flow Rate (Capacity) | 42 l/min (1.5 CFM) |
| Stages | Doble Stage |
| Refrigerants compatibles | R12, R22, R134a, R410a |
9. Garantia i Suport
9.1 Informació de la garantia
The Wipcool 2F0 Double Stage Vacuum Pump comes with a 1 anys de garantia from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from misuse, abuse, unauthorized modification, or failure to follow operating instructions.
Conserveu el vostre comprovant de compra per a reclamacions de garantia.
9.2 Atenció al client
For technical assistance, warranty claims, or inquiries regarding your Wipcool 2F0 vacuum pump, please contact your retailer or the authorized service center. Provide your model number (2F0) and purchase details when contacting support to expedite assistance.