1. Producte acabatview
The Villastar YC-020 Pool Heat Pump is an energy-efficient solution designed to heat swimming pools, extending the usable swimming season. This heat pump is suitable for both inground and above-ground pools, providing consistent warmth with optimized energy consumption.

Imatge 1.1: Frontal view of the Villastar YC-020 Pool Heat Pump.
1.1 Característiques clau
- Capacitat de calefacció: Provides 68,000 BTU/hr output, suitable for pools up to 14,000 gallons.
- Eficiència energètica: Features a thermal conversion rate (COP) of 5.67, indicating efficient heat generation per unit of electricity.
- Interval de temperatura de funcionament: Functions effectively in outdoor temperatures from 19.4°F to 109.4°F, heating water up to 104°F.
- Construcció duradora: Constructed with a robust galvanized steel casing for enhanced durability and resistance to rust.
- Titanium Heat Exchanger: Equipped with a pure titanium water heat exchanger for efficient and corrosion-resistant heat transfer.
- Interfície fàcil d'utilitzar: Features an LED display for water temperature and intuitive control settings.

Image 1.2: Various angles of the Villastar YC-020 Pool Heat Pump, showcasing its design and connections.
1.2 Compatibilitat de la piscina
This heat pump is designed for versatility, accommodating various pool types and sizes:
- Inground pools up to 14,000 gallons.
- Above-ground pools up to 13,000 gallons.
- Suitable for pool dimensions ranging from 13 x 26 ft to 19 x 38 ft.

Imatge 1.3: Ex.amples of compatible pool types, including inflatable, frame, and small inground pools.

Image 1.4: Calendar comparison illustrating the potential extension of the swimming season when using the Villastar Pool Heat Pump.
2. Informació de seguretat
Read all safety warnings and instructions carefully before installing, operating, or performing maintenance on the heat pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.
- Desconnecteu sempre l’alimentació abans de donar servei a la unitat.
- Assegureu-vos una correcta connexió a terra per evitar riscos elèctrics.
- Do not operate the unit if any part is damaged or if the power cord is frayed.
- Mantingueu els nens i les mascotes allunyats de la unitat durant el funcionament.
- Ensure adequate ventilation around the unit. Do not block air intake or exhaust.
- Installation must comply with all local electrical and plumbing codes.
3. Contingut del paquet
Verify that all components are present and undamaged upon unpacking. If any items are missing or damaged, contact customer support immediately.
- Villastar YC-020 Pool Heat Pump Unit
- User Manual (located inside the metal housing)
- Water Pipe Connectors (1.2"/32mm)
- Hoses and necessary fittings
- Mounting feet/pads

Image 3.1: The heat pump unit shown with its accompanying accessories and user manual.
4. Configuració i instal·lació
Proper installation is crucial for the heat pump's performance and longevity. While the unit is designed for easy setup, it is recommended to consult a qualified professional for electrical connections.
4.1 Selecció del lloc
- Trieu un lloc amb un flux d'aire adequat, allunyat d'obstacles.
- Ensure the ground is level and stable enough to support the unit's weight (Net Weight: 168 lbs).
- Position the unit close to the pool and existing filtration system to minimize plumbing runs.
4.2 Connexions de fontaneria
The heat pump should be installed after the pool filter and before any chemical feeders (e.g., chlorinator) in the pool's circulation system.
- Connect the pool's return line from the filter to the heat pump's water inlet.
- Connect the heat pump's water outlet to the pool's return line leading back to the pool.
- Use the provided 1.2"/32mm water pipe connections and ensure all connections are secure and leak-free.

Image 4.1: Schematic diagram illustrating the typical plumbing connections for the heat pump within a pool's filtration system.

Imatge 4.2: Un example of the heat pump installed in a backyard setting, connected to a pool's existing pump and filter.
4.3 Connexions elèctriques
The unit requires a 230V/60Hz power supply. Electrical installation should be performed by a qualified electrician to ensure compliance with local codes and safety standards.
- Ensure the power circuit is dedicated and adequately sized for the heat pump's maximum current draw (25.5A).
- Install appropriate circuit breakers and disconnects as required by local regulations.
4.4 Inici inicial
- After plumbing and electrical connections are complete, ensure the pool pump is running and water is flowing through the heat pump.
- Engegueu l'alimentació de la bomba de calor.
- The LED display will illuminate. Set your desired water temperature using the control panel.
- Allow the unit to run for several hours to begin heating the pool water. The time required to reach the desired temperature will vary based on pool size, ambient temperature, and initial water temperature.
5. Funcionament
The Villastar YC-020 Pool Heat Pump is designed for straightforward operation.
5.1 Tauler de control
The unit features an LED display that shows the current water temperature and allows for adjustment of settings. Refer to the detailed instructions in the physical user manual for specific button functions and menu navigation.
5.2 Configuració de temperatura
- Rang de temperatura de calefacció: 46°F - 104°F.
- Interval de temperatura de refrigeració: 46°F - 82°F (if cooling function is available on your model).
- Adjust the desired temperature using the up/down arrows on the control panel.
5.3 Consells d'ús
- For optimal heating, run the heat pump during the warmest parts of the day.
- Use a pool cover to minimize heat loss, especially overnight.
- Ensure the pool's filtration system is running whenever the heat pump is operating.
6. Manteniment
Regular maintenance ensures the longevity and efficient operation of your heat pump.
6.1 Comprovacions rutinàries
- Neteja les bobines: Periodically inspect and clean the evaporator coils (fins) to remove dirt, leaves, and debris. A clean coil ensures efficient heat exchange.
- Flux d'aire clar: Ensure that there are no obstructions around the unit that could impede airflow to the fan or coils.
- Comproveu si hi ha fuites: Regularly inspect plumbing connections for any signs of water leaks.
- Inspeccioneu les connexions elèctriques: Assegureu-vos que totes les connexions elèctriques estiguin segures i lliures de corrosió.
6.2 Hivernació (per a climes freds)
If you live in an area where temperatures drop below freezing, proper winterization is essential to prevent damage to the unit.
- Disconnect the power supply to the heat pump.
- Drain all water from the heat pump's plumbing lines and heat exchanger. This may involve disconnecting hoses and opening drain plugs.
- Store the unit in a protected area if possible, or cover it with a breathable, waterproof cover if it remains outdoors.
7. Solució De Problemes
This section provides solutions to common issues you might encounter. For problems not listed here, or if solutions do not resolve the issue, contact customer support.
| Problema | Causa possible | Solució |
|---|---|---|
| La bomba de calor no s'encén | Sense font d'alimentació L'interruptor automàtic es va disparar Cablejat defectuós | Check power connection and wall outlet Reinicialitza l'interruptor Consulteu un electricista |
| Water not heating sufficiently | Temperatura ambient baixa Serpentins d'evaporador bruts Configuració de temperatura incorrecta Flux d'aigua insuficient | Heat pump efficiency decreases in cold weather Neteja les bobines Adjust desired temperature Ensure pool pump is running and filter is clean |
| Unitat que fa un soroll inusual | Restes al ventilador Components solts Compressor issue | Inspect and remove debris Check for loose panels or screws Contacta amb l'assistència al client |
| Fuga d'aigua | Connexions de fontaneria soltes Condensació Fuga interna | Estrènyer les connexions Condensation is normal during operation; check drain hose Contacta amb l'assistència al client |
8. Especificacions
Detailed technical specifications for the Villastar YC-020 Pool Heat Pump.
| Especificació | Valor |
|---|---|
| Número de model | YC-020 |
| Capacitat de calefacció (BTU/h) | 68,000 |
| Power Input (BTU/hr) | 11,752 (at 80°F Air, 80°F Water, 63% RH) |
| COP (Coeficient de rendiment) | 5.67 (at 80°F Air, 80°F Water, 63% RH) |
| Font d'alimentació | 230V/60Hz |
| Corrent màxima (A) | 25.5 |
| Setting Temperature Range (Heating) | 46 °C - 104 °C |
| Running (Air) Temperature Range | 19.4 °C - 109.4 °C |
| Dimensions netes (LxWxH) | 40 x 17 x 32 polzades |
| Pes net | 168 lliures |
| Nivell de soroll | 62 dB(A) |

Imatge 8.1: Superposició dimensionalview of the Villastar YC-020 Pool Heat Pump.
9. Garantia i Suport
For warranty information and customer support, please refer to the specific details provided within the physical user manual included with your product. It is recommended to keep your purchase receipt for warranty claims.
If you require technical assistance or have questions regarding your Villastar Pool Heat Pump, please consult the contact information provided in your product documentation.