Introducció
This manual provides essential information for the safe and effective operation of your OWON CM2100 Digital AC/DC Clamp Meter. Please read this manual thoroughly before use and retain it for future reference. The CM2100 is a portable, true RMS clamp meter designed for measuring AC/DC current, AC/DC voltage, resistance, capacitance, diode, and non-contact voltage (NCV).
Informació de seguretat
ADVERTÈNCIA: Per evitar descàrregues elèctriques o lesions personals, llegiu i comprengueu tota la informació de seguretat abans d'utilitzar aquest producte.
- Respecteu sempre els codis de seguretat locals i nacionals.
- No utilitzeu el mesurador si sembla danyat o si l'aïllament està compromès.
- No apliqueu més del volum nominaltage, tal com està marcat al comptador, entre els terminals o entre qualsevol terminal i terra.
- Tingueu precaució quan treballeu amb voltagper sobre de 30 V CA RMS, 42 V pic o 60 V CC. Aquests voltagsuposen un risc de xoc.
- Remove the test leads from the meter before opening the battery cover.
- Assegureu-vos que l'interruptor de funció estigui en la posició correcta per a la mesura que s'està realitzant.
- No feu servir el mesurador al voltant de gas, vapor o pols explosius.
- Always use appropriate personal protective equipment (PPE).
Producte acabatview i Components
Familiarize yourself with the various parts of your CM2100 clamp meter before operation.

Imatge: Detailed diagram of the OWON CM2100 clamp meter, highlighting its key components such as the NCV sensor, pincher head trigger, function selection knob, DCA reset/BLE button, function selector, NCV light, LCD display, numerical lock/backlight switch, capacity/resistance/voltage/frequency/diode/ON-OFF input jack, and common-end jack. Dimensions are also indicated.
- Sensor NCV: Detects non-contact voltage.
- Pincher Head Trigger: Obre i tanca el clamp mandíbules.
- Botó de selecció de funcions: Rotates to select different measurement modes (e.g., V~, V=, A~, A=, Ω, NCV, VFC, Hz%).
- DCA Reset/BLE Button: Used for DC current zeroing and Bluetooth (BLE) activation on compatible models (CM2100B).
- Selector de funcions: Toggles between specific functions within a mode (e.g., AC/DC voltage, resistance/capacitance).
- NCV Light: Illuminates to indicate non-contact voltage detecció.
- Pantalla LCD: Mostra lectures de mesura, unitats i indicadors.
- Numerical Lock/Backlight Switch: Locks the current reading (HOLD) and activates the display backlight.
- Preses d'entrada: Per connectar els cables de prova per a voltage, resistance, capacitance, diode, and continuity measurements.
- Common-End Jack: The negative (-) input for test leads.
Què hi ha a la caixa
Upon opening the package, verify that all items listed below are present and undamaged.

Imatge: Contents of the OWON CM2100 package, including the CM2100 clamp meter, a pair of multimeter test leads (red and black), a small bolt driver, a quick guide, and a soft carrying bag.
- OWON CM2100 Clamp Mesurador
- Multimeter Test Leads (Red and Black)
- Bolt Driver (for battery compartment)
- Guia ràpida
- Bossa de transport suau
Configuració
Instal·lació de la bateria
- Assegureu-vos que el comptador estigui apagat.
- Localitzeu el compartiment de la bateria a la part posterior del mesurador.
- Use the provided bolt driver to loosen the screw securing the battery cover.
- Traieu la tapa de la bateria.
- Insert the Lithium Metal battery (included) according to the polarity markings inside the compartment.
- Torneu a col·locar la tapa de la bateria i premeu el cargol.
Encès inicial
Rotate the function selection knob from OFF to any measurement function to power on the meter. The LCD display will illuminate.
Instruccions de funcionament
Selecció de la funció
Rotate the central knob to select the desired measurement function. The meter features an automatic range for most measurements, simplifying operation.

Imatge: Acabatview of the OWON CM2100's multiple measurement functions, including Resistance (Ω), NCV, VFC, HOLD, ON/OFF (continuity), LCD, Capacitance, Diode, Overload Protection, Low Battery Alert, Buzzing Prompt, and True RMS. It also highlights the 20000 counts, auto range, AC/DC voltage, and AC/DC current measurement capabilities.
Modes de mesura
- AC/DC Current Measurement (A~ / A=):
Rotate the knob to the 'A~' or 'A=' position. Press the trigger to open the clamp jaws and enclose a single conductor. Ensure the conductor is centered within the jaws for accurate readings. The display will show the current value. For DC current, press the DCA Reset button to zero the reading before measurement.
- Volum AC / DCtage Measurement (V~ / V=):
Insert the red test lead into the VΩHz input jack and the black test lead into the COM jack. Rotate the knob to 'V~' for AC voltage o 'V=' per a vol DCtage. Connect the test leads in parallel to the circuit or component to be measured. The display will show the voltage valor.
- Resistance Measurement (Ω):
Insert test leads as for voltage. Rotate the knob to the 'Ω' position. Connect the test leads across the component. The display will show the resistance value in Ohms (Ω).
- Mesura de la capacitat:
Insert test leads as for voltage. Rotate the knob to the 'Ω' position and use the Function Selector button to cycle to capacitance mode (usually indicated by 'nF', 'µF'). Connect the test leads across the capacitor. The display will show the capacitance value.
- Prova de díode:
Insert test leads as for voltage. Rotate the knob to the 'Ω' position and use the Function Selector button to cycle to diode test mode (indicated by a diode symbol). Connect the red lead to the anode and the black lead to the cathode of the diode. The display will show the forward voltage gota.
- Prova de continuïtat:
Insert test leads as for voltage. Rotate the knob to the 'Ω' position and use the Function Selector button to cycle to continuity mode (indicated by a buzzer symbol). If the resistance is below a certain threshold, the buzzer will sound, indicating continuity.
- Vol. Sense contactetagDetecció de e (NCV):
Rotate the knob to the 'NCV' position. Bring the NCV sensor (top part of the clamp meter) close to an AC voltage source. The NCV light will illuminate, and an audible beep will sound, with increasing frequency as the meter gets closer to the voltage font.
- VFC (Variable Frequency Drive) Measurement:
Rotate the knob to the 'VFC' position. This mode is designed for measuring AC voltage and frequency of variable frequency drives, providing more stable readings in such environments.
- Frequency (Hz%) Measurement:
Rotate the knob to the 'Hz%' position. This mode measures the frequency of AC signals. Connect test leads as for voltage measurement. The display will show the frequency in Hertz (Hz).
Funcions addicionals
- Funció HOLD: Press the HOLD button (often combined with backlight) to freeze the current reading on the display. Press again to release.
- Il·luminació de fons: Press and hold the HOLD/Backlight button to activate the display backlight for better visibility in low-light conditions. Press and hold again to turn off.
- RMS veritable: The CM2100 is a True RMS meter, meaning it accurately measures AC voltage and current for both sinusoidal and non-sinusoidal waveforms.
- Bluetooth Communication (CM2100B model only): If you have the CM2100B model, activate Bluetooth by pressing the BLE button. This allows remote data viewing and instrument control via a compatible smartphone application.

Imatge: Examples of the OWON CM2100 clamp meter in use, demonstrating capacitance measurement for maintenance, NCV (Non-Contact Voltage) inductive measurement, circuit board resistance measurement, and diode measurement.
Manteniment
Neteja
Netegeu el comptador amb anuncisamp drap i detergent suau. No utilitzeu abrasius ni dissolvents. Mantingueu els terminals d'entrada lliures de brutícia i humitat.
Canvi de bateria
When the low battery indicator appears on the display, replace the battery promptly to ensure accurate measurements. Refer to the "Battery Installation" section under Setup for instructions.
Emmagatzematge
If the meter is not used for an extended period, remove the battery to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
Resolució de problemes
| Problema | Causa possible | Solució |
|---|---|---|
| El mesurador no s'encén. | Bateria morta o instal·lada incorrectament. | Check battery polarity or replace the battery. |
| No reading or "OL" displayed. | Overload, open circuit, or incorrect function selected. | Ensure the circuit is closed, select the correct function, or check if the measured value exceeds the meter's range. |
| Lectures inexactes. | Low battery, poor test lead connection, or external interference. | Replace battery, ensure secure connections, move away from strong electromagnetic fields. |
| NCV no detecta el volumtage. | Weak signal, incorrect distance, or meter malfunction. | Ensure the sensor is close to the AC source. Test with a known live circuit. |
Especificacions
| Paràmetre | Valor |
|---|---|
| Marca | OWON |
| Model | CM2100 (QD-CM2100) |
| Tipus de mesura | Ammeter, Voltmeter |
| Mostra els recomptes | 20000 recomptes |
| RMS veritable | Sí |
| Corrent CA / CC | Fins a 100A |
| Volum AC / DCtage | Fins a 600V |
| AC Frequency Response | Fins a 1000 Hz |
| Vol. Sense contactetage (NCV) | Sí |
| VFC Function | Sí |
| Comunicació Bluetooth | Available on CM2100B model |
| Bateries | 1 bateria de metall de liti (inclosa) |
| Pes de l'article | 0.5 quilograms (1.1 lliures) |
| Dimensions (L x A x A) | 9.84 x 5.91 x 7.09 polzades (aproximadament 25 x 15 x 18 cm) |
| Certificacions | CE, RoHS |
Garantia i Suport
OWON products are designed for reliability and performance. For warranty information or technical support, please refer to the official OWON weblloc web o poseu-vos en contacte amb el vostre distribuïdor local. Conserveu el rebut de compra com a comprovant de compra per a reclamacions de garantia.
Per a més ajuda, podeu visitar el OWON Store on Amazon.