KETOTEK JP-KT3400

KETOTEK Digital Humidity and Temperature Controller Plug User Manual

Model: JP-KT3400

1. Producte acabatview

The KETOTEK Digital Humidity and Temperature Controller is a versatile device designed to precisely manage environmental conditions. It integrates both humidity and temperature control functions, making it suitable for a wide range of applications such as incubators, greenhouses, reptile habitats, and home environments. This controller features multiple operating modes, alarm functions, and data storage capabilities to ensure stable and reliable operation.

KETOTEK Digital Humidity and Temperature Controller with icons representing its functions

Imatge 1.1: Acabatview of the KETOTEK Digital Humidity and Temperature Controller, highlighting its various functions including humidity control, temperature control, alarms, calibration, reset, memory, button sound settings, and error messages.

Característiques principals:

2. Instruccions de configuració

2.1 Desembalatge i inspecció

Carefully remove the controller from its packaging. Inspect the device and its sensor for any signs of damage. Ensure all components listed in the package contents are present.

2.2 Connexió del dispositiu

  1. Plug the KETOTEK controller directly into a standard power outlet.
  2. The external sensor is already connected to the main unit. Ensure the sensor cable is not damaged.
  3. Place the sensor in the environment where humidity and temperature need to be monitored and controlled. Ensure it is not directly exposed to water or extreme conditions that could damage it.
  4. Plug your humidifier, dehumidifier, heater, or cooler into the outlet on the front of the KETOTEK controller.
KETOTEK Digital Humidity and Temperature Controller plugged into an outlet, with its sensor placed inside a reptile terrarium next to a small turtle.

Imatge 2.1: Proper setup of the controller with the sensor placed inside a terrarium for environmental monitoring.

2.3 Encès inicial

Once plugged in, the display will light up, showing the current measured humidity and temperature. The device is now ready for configuration.

3. Instruccions de funcionament

The controller features a clear digital display and four buttons: MODE, SET, UP/CLK, i ABAIX. These buttons are used to navigate menus and adjust settings.

Close-up of the KETOTEK Digital Humidity and Temperature Controller display and buttons, with labels for each part.

Imatge 3.1: Detallada view of the controller's display and control buttons.

3.1 Understanding Operating Modes

The controller supports four primary operating modes:

Four display examples showing different operating modes: Humidification, Dehumidification, Heating, and Cooling.

Imatge 3.2: Visual representation of the four operating modes on the controller's display.

3.2 Setting Humidity Control Parameters

  1. Premeu el botó MODE button to cycle through the modes until "HC mode" is displayed.
  2. Manteniu premut el botó SET button for 3 seconds to enter the setting menu.
  3. Ús UP/CLK or ABAIX buttons to adjust the "Start Humidity" value. This is the humidity level at which the connected device will turn ON (for humidification) or OFF (for dehumidification).
  4. Premeu SET again to move to "Stop Humidity". Adjust this value using UP/CLK or ABAIX. This is the humidity level at which the connected device will turn OFF (for humidification) or ON (for dehumidification).
  5. Mantén premut SET durant 3 segons per desar la configuració i sortir.
Display showing humidity settings: Measured Humidity, Start Humidity, and Stop Humidity.

Imatge 3.3: Example of humidity control settings on the display.

3.3 Setting Temperature Control Parameters

  1. Premeu el botó MODE button to cycle through the modes until "TC mode" is displayed.
  2. Manteniu premut el botó SET button for 3 seconds to enter the setting menu.
  3. Ús UP/CLK or ABAIX buttons to adjust the "Start Temperature" value. This is the temperature at which the connected device will turn ON (for heating) or OFF (for cooling).
  4. Premeu SET again to move to "Stop Temperature". Adjust this value using UP/CLK or ABAIX. This is the temperature level at which the connected device will turn OFF (for heating) or ON (for cooling).
  5. Mantén premut SET durant 3 segons per desar la configuració i sortir.
Display showing temperature settings: Measured Temperature, Start Temperature, and Stop Temperature.

Imatge 3.4: Example of temperature control settings on the display.

3.4 Setting Alarm Functions

The controller can alert you when humidity or temperature exceeds or falls below set thresholds.

3.4.1 Humidity Alarm (HC Alarm)

  1. Premeu el botó MODE button until "HC Alarm" is displayed.
  2. Manteniu premut el botó SET botó durant 3 segons.
  3. Ús UP/CLK or ABAIX to set the desired humidity alarm threshold.
  4. Mantén premut SET durant 3 segons per desar i sortir.
Display showing humidity alarm settings: Measured Humidity and Humidity Alarm threshold.

Imatge 3.5: Humidity alarm setting interface.

3.4.2 Temperature Alarm (TC Alarm)

  1. Premeu el botó MODE button until "TC Alarm" is displayed.
  2. Manteniu premut el botó SET botó durant 3 segons.
  3. Ús UP/CLK or ABAIX to set the desired temperature alarm threshold.
  4. Mantén premut SET durant 3 segons per desar i sortir.
Display showing temperature alarm settings: Measured Temperature and Temperature Alarm threshold.

Imatge 3.6: Temperature alarm setting interface.

3.5 Calibració

To calibrate the humidity or temperature readings:

  1. Manteniu premut el botó UP/CLK i MODE buttons simultaneously for 3 seconds to enter calibration mode.
  2. Ús UP/CLK or ABAIX to adjust the humidity calibration value (range: -10% to +10% RH).
  3. Premeu SET to switch to temperature calibration. Adjust the temperature calibration value (range: -9.9°C to +9.9°C) using UP/CLK or ABAIX.
  4. Manteniu premut el botó MODE button for 3 seconds to save the calibration and exit.

3.6 Funció de reinici

To reset the controller to factory default settings:

  1. Locate the reset button (small hole) on the side of the device.
  2. Use a thin, pointed object (like a paperclip) to press and hold the reset button for 3 seconds.
  3. The device will restart, and all settings will revert to their default values.
Image showing the location of the reset button on the side of the KETOTEK controller.

Imatge 3.7: Location of the reset button.

3.7 Canvi d'unitats de temperatura (°C/°F)

Per canviar entre Celsius i Fahrenheit:

3.8 Button Sound Settings

To enable or disable the button press sound:

Display showing the button sound icon and indicating how to enable/disable it.

Imatge 3.8: Button sound setting.

4. Manteniment

4.1 Neteja del sensor

To ensure accurate readings, periodically clean the sensor probe. Gently wipe the sensor with a soft, dry cloth. Avoid using abrasive cleaners or submerging the sensor in liquids, as this can damage the sensitive components.

4.2 Atenció general

5. Solució De Problemes

This section addresses common issues you might encounter with your KETOTEK Digital Humidity and Temperature Controller.

ProblemaCausa possibleSolució
"E1" or "E2" displayedSensor disconnected or short-circuited.Check the sensor connection. Ensure it is securely plugged into the controller. If the error persists, the sensor may be faulty and require replacement.
"HHH" or "LLL" displayedMeasured humidity/temperature is outside the measurable range.Ensure the environment's conditions are within the controller's operating range (Humidity: 20-95% RH, Temperature: -10°C to 50°C). If the environment is within range, the sensor might be faulty.
Connected device not turning ON/OFFIncorrect settings, device malfunction, or power issue.Verify your "Start" and "Stop" humidity/temperature settings. Ensure the connected device is functioning correctly by plugging it directly into a wall outlet. Check if the controller is receiving power.
Lectures inexactesSensor dirty, calibration needed, or sensor malfunction.Clean the sensor as described in the Maintenance section. Perform a calibration as described in section 3.5. If readings remain inaccurate, the sensor may need replacement.
L'alarma sona contínuamentEnvironment conditions are outside the set alarm thresholds.Check the current humidity/temperature and compare it to your alarm settings. Adjust the environment or the alarm thresholds if necessary.

6. Especificacions

ParàmetreValor
Número de modelJP-KT3400
MarcaKETOTEK
Interval de control d'humitat20% ~ 95% HR
Interval de control de temperatura-10 ° C ~ 50 ° C (14 ° F ~ 122 ° F)
Humidity Calibration Range-10% ~ 10% RH
Interval de calibració de temperatura-9.9 °C ~ 9.9 °C
Precisió de la mesura±5% RH / ±2°F / ±1°C
SortidaMax 15A / 120V
Tipus de visualitzacióDigital
Pes del producte260 g
Dimensions del paquet15.8 x 8.2 x 7.9 cm
Accessoris inclosos1*Humidity Controller, 1*Instruction Manual
Diagram showing the dimensions of the KETOTEK Digital Humidity and Temperature Controller and its external sensor.

Imatge 6.1: Physical dimensions of the controller and sensor.

7. Garantia i Suport

KETOTEK products are designed for reliability and performance. For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official KETOTEK weblloc web. Si us plau, conserveu el comprovant de compra per a reclamacions de garantia.

Documents relacionats - JP-KT3400

Preview Manual d'instruccions del termòstat endollable KETOTEK KT3100 EUA
Apreneu a utilitzar el termòstat endollable KETOTEK KT3100 US, un controlador de temperatura versàtil per a aplicacions de calefacció, refrigeració i temporització en llars, hivernacles i aqüicultura. Aquest manual tracta la configuració, el control de temperatura, els modes de temporització i les especificacions.
Preview Ketotek KT3200 Plug-in Thermostat User Manual
Instruction manual for the Ketotek KT3200 Plug-in Thermostat, a Day/Night Temperature Controller. Details operation modes (M1 TC, M2 TC+Timer, M3 Timer), temperature calibration, reset functions, and memory features.
Preview Manual d'instruccions del controlador de temperatura i humitat KETOTEK KT100 Fahrenheit
Manual d'instruccions complet per al controlador de temperatura i humitat KETOTEK KT100 Fahrenheit, que detalla les especificacions, el cablejat, les instruccions d'operació i els procediments de calibratge per al control de temperatura i humitat.
Preview Manual d'instruccions del termòstat endollable KETOTEK KT3100 EUA
Apreneu a utilitzar el termòstat endollable KETOTEK KT3100 US. Aquest manual tracta el control de la temperatura (calefacció/refrigeració), els modes de temporització (cicle, compte enrere), el calibratge i les especificacions per a la gestió intel·ligent de la temperatura.
Preview KETOTEK KTF0172 Smart Thermostat User Manual and Installation Guide
Comprehensive guide for KETOTEK KTF0172 series smart thermostats, covering installation, display features, WiFi setup, and app integration with Alexa and Google Assistant. Includes models KTF0172A, KTF0172B, and KTF0172C.
Preview Termòstat intel·ligent KETOTEK Sèrie KTF0155/KTF0163: Guia d'instal·lació i usuari
Guia completa per als termostats intel·ligents de les sèries KETOTEK KTF0155 i KTF0163. Cobreix la instal·lació, els diagrames de cablejat per a escalfadors elèctrics, escalfadors d'aigua i calderes, la configuració del Wi-Fi i la resolució de problemes. Controla la calefacció de casa teva de manera eficient.