1. Introducció
The NJOY Echo Pro 2000 is an advanced Uninterruptible Power Supply (UPS) designed to provide reliable power protection for critical equipment such as servers, workstations, and networking devices. Featuring double conversion online technology, it delivers a pure sine wave output, ensuring the highest degree of compatibility and protection for sensitive electronics. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Echo Pro 2000 UPS.
Figura 1.1: Frontal view of the NJOY Echo Pro 2000 UPS. This image shows the main unit with its front panel display and control buttons.
2. Informació de seguretat
Please read and follow all safety instructions carefully before installing, operating, or servicing the UPS. Failure to comply with these instructions may result in electric shock, fire, or serious injury.
- Seguretat elèctrica: El SAI conté volums perillosostagNo intenteu desmuntar la unitat. El manteniment només l'ha de realitzar personal qualificat.
- Seguretat de la bateria: Batteries can present a risk of electrical shock and high short-circuit current. Observe proper polarity when connecting batteries. Do not dispose of batteries in a fire.
- Medi ambient: Install the UPS in a well-ventilated area, free from excessive dust, humidity, and corrosive substances. Avoid direct sunlight and heat sources.
- Posada a terra: Ensure the UPS is properly grounded to prevent electrical shock.
- Apagada d'emergència (EPO): Familiarize yourself with the EPO function for immediate shutdown in emergencies.
3. Producte acabatview
3.1 Característiques clau
- Double Conversion Online Technology: Provides continuous, clean power by converting incoming AC to DC and then back to AC, isolating connected equipment from utility power fluctuations.
- Sortida d'ona sinusoïdal pura: Ensures compatibility with all types of electronic loads, preventing distortion and electrical noise.
- Baix nivell de soroll: Operates at less than 40 dB, suitable for office environments.
- Gestió de programari: Includes specialized software for remote monitoring, scheduled power on/off, battery tests, and complete UPS configuration.
- Ports de comunicació: Equipped with RS232, HID USB, and EPO ports. An optional SNMP card slot is available for advanced network monitoring.
- Bateries internes: Features 4 x 12V7Ah sealed lead-acid batteries for reliable backup power.
3.2 Connexions del panell posterior
Figure 3.1: Rear panel of the NJOY Echo Pro 2000 UPS, showing various connection ports.
- Interfície RS232: For serial communication with a computer or network device.
- Schuko Outlets (x4): Output receptacles for connecting protected equipment.
- Interruptor d'entrada: Overcurrent protection for the UPS input.
- Ventilador: Cooling fan for internal components.
- SNMP Slot: Expansion slot for an optional SNMP card (not included) for network management.
- EPO (Emergency Power Off): Connector for remote emergency shutdown.
- Interfície USB: For USB communication with a computer.
- Entrada de CA: Power input connector for the UPS.
4. Configuració
Follow these steps to properly set up your NJOY Echo Pro 2000 UPS:
- Desembalatge: Carefully unpack the UPS and inspect it for any shipping damage. Report any damage to your dealer.
- Col·locació: Place the UPS in a clean, dry, and well-ventilated indoor environment. Ensure adequate clearance around the unit for proper airflow. Avoid placing it near heat sources or in direct sunlight.
- Càrrega inicial: Connect the UPS to a grounded AC power outlet using the provided power cord. Allow the UPS to charge for at least 8 hours before connecting any equipment to ensure optimal battery performance. The LCD display will indicate charging status.
- Equip de connexió: Once the UPS is fully charged, connect your critical equipment (servers, computers, monitors, etc.) to the Schuko output receptacles on the rear panel. Do not connect surge suppressors or power strips to the UPS output.
- Configuració de la comunicació: For monitoring and management, connect the UPS to your computer using the provided USB or RS232 cable. Install the specialized management software (refer to Section 5.2).
- EPO Connection (Optional): If using the Emergency Power Off function, connect the EPO cable to the designated port.
5. Instruccions de funcionament
5.1 Engegada/apagada
- Per encendre: Press and hold the 'ON' button on the front panel for approximately 2 seconds until the UPS powers on and the LCD display illuminates.
- Per apagar: Press and hold the 'OFF' button for approximately 2 seconds. The UPS will shut down, and the display will turn off.
Pantalla LCD 5.2 i botons de control
The front panel LCD provides real-time status information. Use the 'ENTER' and 'ESC' buttons to navigate through the display menus and view various parameters such as input/output voltage, battery level, load level, and operating mode.
5.3 Gestió de programari
The included software allows for comprehensive monitoring and control of the UPS. Install the software on a connected computer to:
- Monitor real-time UPS status and parameters.
- Schedule automatic power on/off and battery tests.
- Configure UPS settings and alarm thresholds.
- Receive notifications for power events.
- Perform safe shutdown of connected computer systems during extended power outages.
Figura 5.1: Example of the UPS management software interface, showing status and configuration options.
6. Manteniment
Regular maintenance ensures the longevity and optimal performance of your UPS.
- Cura de la bateria: The UPS contains sealed lead-acid batteries. These batteries typically last 3-5 years under normal operating conditions. Replace batteries when their runtime significantly decreases. Only use replacement batteries of the same type and rating (4 x 12V7Ah). Battery replacement should be performed by qualified service personnel.
- Neteja: Keep the UPS clean and free of dust. Use a dry cloth to wipe the exterior. Do not use liquid cleaners or solvents. Ensure ventilation openings are clear of obstructions.
- Condicions ambientals: Maintain the UPS within the recommended operating temperature and humidity ranges to prolong its lifespan.
- Autocomprovació: Periodically perform a battery self-test using the management software or front panel controls to assess battery health.
7. Solució De Problemes
This section provides solutions to common issues you might encounter with your UPS. If the problem persists, contact technical support.
| Problema | Causa possible | Solució |
|---|---|---|
| El SAI no s'encén | No AC input; Low battery; UPS fault | Check AC power cord connection; Allow UPS to charge; Contact support if fault persists. |
| El SAI emet un so continu | Overload; Low battery; UPS fault | Reduce connected load; Allow UPS to charge; Check LCD for error codes. |
| Temps de còpia de seguretat curt | Overload; Batteries need replacement | Reduce connected load; Perform battery test and replace if necessary. |
| Software not communicating with UPS | Incorrect cable; Driver issue; Software settings | Ensure correct USB/RS232 cable is used; Reinstall drivers; Check software communication settings. |
8. Especificacions
| Característica | Especificació |
|---|---|
| Marca | JOIA |
| Número de model | UPOL-OL200EP-CG01B_SIL |
| Tipus de producte | Torre UPS |
| Tecnologia | Online (VFI) Double Conversion |
| Capacitat de potència | 2000 VA / 1600 W |
| Factor de potència de sortida | 0.8 |
| Vol. nominal d'entradatage | 230 V AC |
| Entrada Voltage Rang | 80 - 300 V CA. |
| Freqüència d'entrada | 50 Hz / 60 Hz (auto-sensing) |
| Sortida Nominal Voltage | 208/220/230/240 V AC |
| Forma d'ona de sortida | Onda senyal pura |
| Punts de venda | 4 x Schuko |
| Bateries | 4 x 12V7Ah Sealed Lead-Acid (internal) |
| Eficiència | Fins al 96% |
| Mostra | LCD |
| Ports de comunicació | RS232, HID USB, EPO, SNMP Slot (optional card) |
| Nivell de soroll | <40 dB |
| Dispositius compatibles | Gaming Computers, DVRs, Video Surveillance Systems, WiFi/ADSL/Fiber Modems, Monitors, Printers, TVs, NAS, Servers |
Figure 8.1: Runtime autonomy chart for the NJOY Echo Pro 2000 UPS. This chart illustrates the approximate backup duration at different load levels. For example, at 1600W (100% load), the runtime is approximately 1 minute, while at 400W (25% load), it is approximately 17 minutes.
9. Informació de la garantia
For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official NJOY weblloc web. Conserveu el comprovant de compra per a reclamacions de garantia.
10. Suport
If you require technical assistance or have questions regarding your NJOY Echo Pro 2000 UPS, please contact NJOY customer support through their official weblloc web o la informació de contacte que es proporciona a la documentació del producte.