Introducció
The KAIWEETS Smart Multimeter KM602 is a versatile and intelligent digital multimeter designed for precise electrical measurements in various settings. This comprehensive kit includes the KM602 multimeter and a set of durable soft silicone electrician test leads (KET01), making it suitable for automotive, industrial, and household electrical testing. Its smart mode automatically identifies and measures AC/DC voltage, resistance, and continuity, simplifying operation. The built-in rechargeable battery ensures extended use and convenience.
Característiques clau
- Mode intel·ligent: Automatically measures and identifies AC/DC voltage, resistance, and continuity, with optimal range selection for high precision.
- Bateria recarregable: Features a built-in rechargeable battery for prolonged use and convenient charging via cable.
- Aplicació àmplia: Capable of precisely gauging AC and DC voltage, resistance, continuity, AC and DC current, capacitance, frequency, diode, duty cycle, temperature, Non-Contact Voltage (NCV), and live wire detection.
- Seguretat millorada: Complies with IEC CAT.III 600V standards and holds CE and RoHS certifications. Includes two distinct fuse sizes for overload protection and a silicone casing for shock resistance.
- Pantalla HD en color: Improves readability in various lighting conditions.
Contingut del paquet
The KAIWEETS Smart Multimeter KM602 & Soft Silicone Electrician Test Leads Kit includes the following items:
- Multímetre intel·ligent KAIWEETS KM602
- Soft Silicone Electrician Test Leads (KET01)
- Cable de càrrega USB
- Maleta de transport
- Manual d'usuari

Figure 1: Contents of the KAIWEETS Smart Multimeter KM602 & Soft Silicone Electrician Test Leads Kit.
Configuració
Càrrega del multímetre
Before initial use, ensure the multimeter's built-in rechargeable battery is fully charged. Connect the provided USB charging cable to the multimeter's charging port and a suitable USB power source (e.g., computer USB port, USB wall adapter). The display will indicate the charging status.

Figure 2: Charging the KM602 Multimeter.
Connexió de cables de prova
Properly connect the test leads to the multimeter for accurate and safe measurements. Insert the red test lead into the 'INPUT' (positive) jack and the black test lead into the 'COM' (common/negative) jack. Ensure a secure connection. The KET01 test leads feature silicone insulation for flexibility and durability, and a special plug design for reliable contact.

Figure 3: KAIWEETS Soft Silicone Electrician Test Leads and accessories.
Instruccions de funcionament
Encès/Apagat
Press and hold the power button located on the top left of the multimeter to turn it on or off.
Smart Mode Operation
The KM602 defaults to Smart Mode upon power-on. In this mode, the multimeter automatically detects and measures AC/DC voltage, resistance, and continuity. It intelligently selects the appropriate measurement range, eliminating the need for manual range selection for these common tests.

Figure 4: Smart Mode (Auto) display on the KM602 Multimeter.
Manual Mode and Function Selection
To access specific measurement functions beyond Smart Mode (e.g., AC/DC current, capacitance, frequency, diode, duty cycle, temperature, NCV, live wire), press the 'FUNC' button. Each press cycles through available functions. The 'SEL' button can be used to select between AC/DC for certain measurements or other sub-functions.
Vol. Sense contactetage (NCV) Detecció
La funció NCV permet la detecció segura del volum de CAtage without direct contact. Select the NCV function using the 'FUNC' button and bring the top of the multimeter near the conductor. The device will indicate the presence of voltage through audible beeps and visual alerts on the display.
Display Readability
The KM602 features a vibrant Color HD Screen, designed to enhance the reading experience. This display provides clear and bright readings, making it easy to view measurements even in challenging lighting conditions, including bright sunlight or dark environments.

Figure 5: Clear display of the KM602 Multimeter's Color HD Screen.
Informació de seguretat
The KAIWEETS KM602 Multimeter and KET01 Test Leads are designed with user safety as a priority. Adhere to all safety guidelines to prevent injury or damage to the device.
- Compliment: The multimeter is produced to comply with IEC rated CAT.III 600V and has acquired CE and RoHS certifications.
- Protecció de sobrecàrrega: Features two distinct fuse sizes to safeguard against overload conditions.
- C duradorasing: The silicone casing provides extra shock resistance and endures everyday use, protecting the internal components.

Figure 6: Safety specifications for test leads and accessories.
Test Lead Durability
The KET01 test leads are constructed with high-quality silicone insulated wires, offering exceptional resilience and flexibility. They are designed to withstand extreme temperatures, being heat resistant up to 392°F (200°C) and cold resistant down to -76°F (-60°C). The special plug design ensures perfect contact and prevents loosening during use, while the silicone material allows them to withstand significant pulling force (900N Rally).

Figure 7: Durability of silicone insulated wires.

Figure 8: Special design features of KAIWEETS test leads.
Manteniment
- Neteja: Utilitzeu un suau, damp cloth to clean the multimeter and test leads. Do not use abrasive cleaners or solvents.
- Emmagatzematge: Store the device and accessories in the provided carrying case in a cool, dry place away from direct sunlight and extreme temperatures.
- Cura de la bateria: To maintain battery health, charge the multimeter regularly, even if not in frequent use. Avoid fully discharging the battery for extended periods.
- Substitució de fusibles: If a fuse blows due to overload, replace it with a fuse of the correct type and rating as specified in the technical specifications. Refer to the device's internal markings for fuse access.
Resolució de problemes
| Problema | Causa possible | Solució |
|---|---|---|
| El multímetre no s'encén. | Bateria baixa o esgotada. | Charge the multimeter using the provided USB cable. |
| Lectures inexactes. | Incorrect function selected; poor test lead connection; damaged test leads. | Ensure correct function is selected (Smart Mode or Manual); check test lead connections; inspect leads for damage and replace if necessary. |
| La pantalla mostra 'OL' (sobrecàrrega). | Measurement exceeds the selected range or device capability. | In Smart Mode, the device should auto-range. In Manual Mode, select a higher range or ensure the measurement is within the device's specifications. |
| Sense detecció de NCV. | NCV function not selected; no AC voltage present. | Ensure NCV function is active; verify AC voltage presence with another method if possible. |
Especificacions
| Característica | Detall |
|---|---|
| Número de model de l'article | KM602 & KET01 |
| Fabricant | KAIWEETS |
| Font d'alimentació | Funciona amb bateria (recarregable) |
| Estil | KM602 & KET01 |
| Color | Negre |
| Especificació de seguretat complerta | IEC, CE, RoHS, CAT.III 600V |
| Mostra | Color HD Screen, 6000 Counts TRMS |
| Fils de prova | Soft Silicone, CAT III 1000V & CAT IV 600V (KET01) |
Garantia i Suport
KAIWEETS offers a Servei postvenda de 3 anys i lifetime technical assistance for this product. If you have any inquiries, require technical support, or need to claim warranty service, please do not hesitate to contact KAIWEETS customer service through their official channels or the retailer where the product was purchased.