1. Introducció

This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Wipcool Double Stage Vacuum Pump Model 2F3R. Please read this manual thoroughly before operating the pump and retain it for future reference.

The Wipcool 2F3R vacuum pump is specifically designed for use with various refrigerants, including next-generation A2L refrigerants like R32 and R1234YF, as well as traditional refrigerants such as R410A and R22. Its design incorporates features for enhanced safety and performance in HVAC applications.

2. Instruccions de seguretat

Always adhere to the following safety precautions to prevent injury and damage to the equipment.

  • Seguretat elèctrica: Assegureu-vos que la font d'alimentació coincideixi amb el volum de la bombatage (230 Volts). Do not operate with damaged cords or plugs. Always disconnect power before servicing.
  • Compatibilitat amb el refrigerant: This pump is suitable for A2L refrigerants (R32, R1234YF) and other common refrigerants (R410A, R22). When working with flammable refrigerants (A2L), ensure proper ventilation and eliminate all potential ignition sources.
  • Nivell d'oli: Regularly check the oil level using the sight glass. Do not operate the pump without oil or when the oil level is low. Use only recommended vacuum pump oil.
  • Ventilació: Feu funcionar la bomba en una zona ben ventilada per evitar l'acumulació de vapors de refrigerant.
  • Equips de protecció individual (EPI): Wear appropriate PPE, including safety glasses and gloves, when handling refrigerants and operating the pump.
  • Manipulació: The pump weighs approximately 9.8 kg. Lift with care to avoid injury.
  • Condicions ambientals: Avoid operating the pump in wet or excessively dusty environments.

3. Contingut del paquet

Upon unpacking, verify that all items are present and undamaged:

  • Wipcool Double Stage Vacuum Pump 2F3R
  • Manual d'usuari (aquest document)
  • Cable d'alimentació
  • Vacuum Pump Oil (may be included separately or pre-filled)

4. Característiques del producte

The Wipcool 2F3R vacuum pump incorporates several advanced features for reliable performance:

  • Non-Sparking Design: Suitable for use with A2L refrigerants (R32, R1234YF) and other refrigerants (R410A, R22).
  • Tecnologia de motor sense escombretes: Offers a lighter design (over 25% lighter than similar products) and extended service life.
  • Built-in Solenoid Valve: Prevents oil backflow into the system during power outages or shutdown.
  • Overhead Vacuum Gauge: Provides a compact and easy-to-read display of vacuum levels.
  • Integral Cylinder Structure: Enhances reliability and durability.
  • Reinforced Aluminum Alloy Oil Tank: Designed for effective heat dissipation and resistance to chemical corrosion.
  • Oversized Sight Glass: Allows for easy monitoring of oil color and level.
Wipcool 2F3R Double Stage Vacuum Pump, front view
Figura 1: Frontal view of the Wipcool 2F3R Double Stage Vacuum Pump, highlighting its compact design and integrated handle.

5. Configuració

  1. Desembalatge: Traieu amb cura la bomba de buit del seu embalatge. Inspeccioneu-la per detectar qualsevol dany durant l'enviament.
  2. Col·locació: Place the pump on a stable, level surface in a well-ventilated area. Ensure adequate space around the pump for air circulation and heat dissipation.
  3. Ompliment d'oli:
    • Traieu el tap d'ompliment d'oli.
    • Pour appropriate vacuum pump oil into the reservoir until the level is between the MIN and MAX marks on the sight glass. Do not overfill.
    • Torneu a col·locar el tap d'ompliment d'oli de manera segura.
  4. Connexió d'alimentació: Connect the power cord to the pump and then to a grounded electrical outlet matching the specified voltage (230 V).
  5. Comprovació inicial: Before connecting to a system, briefly turn on the pump to ensure it operates smoothly and the oil circulates. Turn off immediately.
Wipcool 2F3R Double Stage Vacuum Pump, side view with oil sight glass
Figura 2: lateral view of the Wipcool 2F3R vacuum pump, showing the oil sight glass for monitoring oil levels and the robust casing.

6. Instruccions de funcionament

Follow these steps for proper operation of the vacuum pump:

  1. Connexió al sistema: Connect the vacuum pump to the system requiring evacuation using appropriate vacuum hoses. Ensure all connections are tight to prevent leaks.
  2. Open System Valves: Open all valves on the manifold gauge set and the system to be evacuated.
  3. Inici de la bomba: Turn on the power switch of the vacuum pump. The pump will begin to draw a vacuum.
  4. Monitor de buit: Observe the overhead vacuum gauge to monitor the vacuum level. Continue operation until the desired vacuum level is achieved, typically indicated by a stable reading.
  5. Isolate Pump: Once the desired vacuum is reached, close the manifold gauge set valves to isolate the system from the pump.
  6. Apagar la bomba: Apagueu la bomba de buit.
  7. Desconnectar: Carefully disconnect the vacuum hoses from the pump and the system.
Wipcool 2F3R Double Stage Vacuum Pump connected to an HVAC system
Figure 3: The Wipcool 2F3R vacuum pump in operation, connected to an HVAC system for evacuation. This image demonstrates a typical setup during use.

7. Manteniment

Regular maintenance ensures optimal performance and extends the life of your vacuum pump.

  • Canvi d'oli: Change the vacuum pump oil regularly, especially after each use with contaminated systems or when the oil appears discolored or cloudy.
    • Assegureu-vos que la bomba estigui apagada i freda.
    • Col·loqueu un recipient adequat sota el tap de drenatge d'oli.
    • Remove the oil drain plug and the oil fill cap to allow oil to drain completely.
    • Replace the drain plug and refill with new, clean vacuum pump oil to the correct level.
  • Neteja: Keep the exterior of the pump clean and free of dust and debris. Ensure cooling fins are not obstructed.
  • Emmagatzematge: When not in use, store the pump in a dry, clean environment. Ensure the oil level is correct before storage.

8. Solució De Problemes

ProblemaCausa possibleSolució
La bomba no arrencaSense corrent, cable d'alimentació defectuós, problema amb el motor.Check power connection and outlet. Inspect power cord for damage. If issues persist, contact support.
Mal rendiment del buitLow oil level, contaminated oil, system leak, clogged intake filter.Check and refill/change oil. Check all system connections for leaks. Inspect and clean intake filter.
Excés de soroll/vibracióLow oil level, worn components, pump not on a level surface.Check and refill oil. Ensure pump is on a stable, level surface. If noise persists, contact support.
Boira d'oli de l'escapamentOverfilled oil, contaminated oil, normal operation with some oil types.Check oil level and adjust if overfilled. Change oil if contaminated. Ensure proper ventilation.

9. Especificacions

AtributValor
Model2F3R
MarcaWipcool
TipusDoble Stage Bomba de buit
Voltage230 Volts
Caudal màxim198 Liters Per Minute (97 CFM)
Cavalls de força3 / 4 HP
Pes de l'article9.8 quilos
Dimensions del producte (LxWxH)43.18 x 22.86 x 33.02 cm
MaterialAcrylic (for certain components)
Font d'alimentacióAC
Compatibilitat amb refrigerantsA2L refrigerants (R32, R1234YF) and other refrigerants (R410A, R22, R12)

10. Garantia i Suport

This Wipcool 2F3R Double Stage Vacuum Pump comes with a 1 anys de garantia des de la data de compra.

For warranty claims, technical support, or service inquiries, please contact your authorized Wipcool dealer or the manufacturer's customer service department. Please have your model number (2F3R) and proof of purchase available when contacting support.

Documents relacionats - 2F3R

Preview Manual d'operació de la nova bomba de buit refrigerant WIPCOOL
Aquest manual proporciona instruccions d'ús, especificacions tècniques, característiques i guia per a la resolució de problemes de les noves bombes de buit refrigerant de WIPCOOL, incloses les bombes individuals.tage, doble stage, i models sense fil.
Preview Bombes de buit WIPCOOL: Guia de selecció i especificacions tècniques
Una guia completa per seleccionar i entendre les bombes de buit WIPCOOL, que detalla les seves característiques, especificacions tècniques i aplicacions per a professionals de la climatització/refrigeració. Cobreix diversos models, incloent-hi la sèrie S i la sèrie F, i destaca el seu rendiment, la compatibilitat amb refrigerants i els elements de disseny únics.
Preview Manual d'operació de la màquina de recuperació de refrigerant WIPCOOL MRM55/MRM550S
Aquest manual proporciona instruccions detallades per al funcionament, les directrius de seguretat, les especificacions i la resolució de problemes de la màquina de recuperació de refrigerant WIPCOOL MRM55/MRM550S.
Preview Manual d'operació de la bomba de condensats WIPCOOL P18/P36
Manual d'operació complet per a les bombes de condensats WIPCOOL P18 i P36, que cobreix les especificacions tècniques, la instal·lació, la seguretat i la resolució de problemes.
Preview WIPCOOL C35S High Pressure Steam Cleaning Machine Operation Manual
This operation manual provides detailed instructions for the WIPCOOL C35S High Pressure Steam Cleaning Machine, covering usage, maintenance, technical specifications, and troubleshooting for optimal performance.
Preview Manual d'instruccions de la màquina de neteja d'aire condicionat a vapor WIPCOOL C30S
Manual d'operació de la màquina de neteja d'aire condicionat a vapor WIPCOOL C30S, que detalla les seves característiques, instruccions d'ús, precaucions de seguretat i resolució de problemes per a una neteja eficaç dels equips d'aire condicionat i refrigeració.