1. Introducció
This user manual provides comprehensive instructions for the installation, operation, and maintenance of your Jebao MCP Series Smart Cross-Flow Wave Pump, specifically the MCP-180 model. Please read this manual thoroughly before using the product to ensure safe and efficient operation. Retain this manual for future reference.

Image 1.1: The Jebao Smart Cross-Flow Pump user manual as found inside the product packaging.
2. Característiques del producte
The Jebao MCP Series Smart Cross-Flow Wave Pump incorporates advanced technology for optimal aquarium water circulation. Key features include:
- WiFi and Manual Control: Offers flexible control options via a dedicated mobile application or the integrated LCD controller.
- Smart AP Mode: Enables direct control without requiring an external Wi-Fi router, creating its own network for convenience.
- SINE Wave Technology: Ensures ultra-quiet operation and highly stable performance, minimizing noise and vibration.
- Cross-Wave Double Impeller Structure: Designed to generate efficient water flow with no dead spots, promoting comprehensive circulation within the aquarium.
- Marine and Freshwater Compatibility: Constructed without exposed copper elements, making it safe for use in both marine and freshwater environments.
- IC Electronic Detection: Features dry/locked rotor protection and automatic power-off upon detecting no water, enhancing safety and product longevity.
- Master and Slave Wireless Control: Allows for synchronized operation of multiple pumps for complex flow patterns.

Imatge 2.1: acabatview of Jebao MCP pump models and their various operational modes.
3. Contingut del paquet
Upon unpacking, please verify that all components are present and undamaged. The standard package for the MCP-180 model includes:
- Jebao MCP-180 Cross-Flow Wave Pump Unit
- LCD Display Controller
- Adaptador d'alimentació
- Manual d'usuari

Image 3.1: The Jebao MCP-180 pump unit and its accompanying LCD controller.
4. Instruccions de seguretat
Per evitar lesions o danys al producte, seguiu sempre les següents pautes de seguretat:
- Desconnecteu sempre l'alimentació abans de realitzar qualsevol manteniment o instal·lació.
- Assegureu-vos que tingueu les mans seques quan manipuleu components elèctrics.
- No feu funcionar la bomba si el cable d'alimentació o l'endoll estan danyats.
- This product is designed for indoor aquarium use only. Do not use it for other purposes.
- Keep the controller and power adapter away from water splashes.
- Ensure the pump is fully submerged in water during operation to prevent dry running.
- Els nens han de ser supervisats per assegurar-se que no juguin amb l'aparell.
5. Configuració
Follow these steps to set up your Jebao MCP-180 wave pump:
5.1 Muntatge de la bomba
- Position the pump unit inside the aquarium, ensuring it is fully submerged and clear of any obstructions.
- Use the magnetic mount to secure the pump to the aquarium glass. Align the external magnet with the internal pump unit.
- Ensure the pump is securely attached and will not move during operation.
5.2 Connexió del controlador
- Connect the pump unit cable to the designated port on the LCD controller.
- Connect the power adapter to the controller's power input port.
- Connecteu l'adaptador d'alimentació a una presa de corrent adequada.
5.3 Engegada inicial i configuració del Wi-Fi
Upon powering on, the controller LCD will illuminate. The pump will enter its default operating mode. For WiFi control:
- Download the 'Jebao Aqua' app from the App Store or Google Play.
- Follow the in-app instructions to connect your pump using Smart AP mode (no router required) or by connecting to your home Wi-Fi network.

Image 5.1: The Jebao Aqua mobile application for WiFi control, available on App Store and Google Play.
6. Instruccions de funcionament
The MCP-180 pump offers various modes and settings for customized water flow.
6.1 Controlador passatview
The LCD controller features several buttons for direct control:
- Botó de mode: Cycles through different operational modes (e.g., Constant, Wave, SINE, Random).
- Botons amunt / avall: Adjust flow intensity or other parameters within a selected mode.
- Botó Reproduir/Pausa: Starts or stops the pump operation.

Image 6.1: The LCD controller displaying current flow settings.
6.2 Modes operatius
Press the 'Mode' button to cycle through the following modes:
- Corrent constant: Provides a steady, continuous flow. Adjust intensity with Up/Down buttons.
- Wave Maker: Generates oscillating wave patterns. Adjust wave intensity and frequency.
- SINE Wave Technology: Produces smooth, natural-looking wave motions with minimal noise.
- Random Flow: Varies flow patterns and intensity unpredictably to simulate natural ocean currents.
- Mode d'alimentació: Temporarily pauses the pump for a set duration (e.g., 10 minutes) to allow for feeding without food being swept away.
- Mode nocturn: Reduces pump activity during nighttime hours for quieter operation and to simulate natural diurnal cycles.
6.3 Control de l'aplicació WiFi
For advanced control and scheduling, use the Jebao Aqua mobile application. The app allows for:
- Precise adjustment of flow rates and wave patterns.
- Setting up daily schedules and custom programs.
- Monitoring pump status.
- Configuring master/slave pump synchronization.
7. Manteniment
Un manteniment regular garanteix un rendiment òptim i allarga la vida útil de la bomba.
7.1 Cleaning the Pump Unit
- Disconnect the power adapter from the electrical outlet.
- Remove the pump unit from the aquarium.
- Carefully disassemble the pump housing to access the impeller.
- Clean the impeller, impeller shaft, and pump housing thoroughly using a soft brush and clean water. Remove any algae, debris, or calcium buildup.
- Rinse all components with clean water.
- Reassemble the pump unit, ensuring all parts are correctly seated.
- Place the pump back into the aquarium and reconnect power.
It is recommended to perform this cleaning every 2-4 weeks, depending on your aquarium's conditions.
8. Solució De Problemes
If you encounter issues with your Jebao MCP-180 pump, refer to the following common problems and solutions:
| Problema | Causa possible | Solució |
|---|---|---|
| La bomba no funciona | No power; Impeller jammed; Dry run protection activated. | Check power connection; Clean impeller; Ensure pump is fully submerged. |
| Flux d'aigua feble | Impeller dirty; Obstruction in pump; Flow setting too low. | Clean impeller and housing; Remove obstructions; Increase flow setting on controller/app. |
| Soroll inusual | Impeller dirty or damaged; Air trapped in pump. | Clean or replace impeller; Gently shake pump to release air. |
| Problemes de connexió Wi-Fi | Incorrect network settings; Router too far; App not updated. | Verify network credentials; Move router closer or use AP mode; Update Jebao Aqua app. |
9. Especificacions
The following table details the specifications for the Jebao MCP Series pumps, including the MCP-180 model:
| Model | Voltage | Watts | Dimensions L × A × A (mm) | Tank Size (cm) | Tank Thickness (mm) |
|---|---|---|---|---|---|
| MCP-70 | DC 24V | 18 | 218×62×40 | 80 | ≤8 |
| MCP-90 | DC 24V | 25 | 283×66×40 | 90 | ≤8 |
| MCP-120 | DC 24V | 45 | 295×72×45 | 120 | ≤15 |
| MCP-150 | DC 24V | 55 | 330×74×48 | 150 | ≤19 |
| MCP-180 | DC 24V | 65 | 340×82×52 | 180 | ≤19 |

Image 9.1: Detailed specifications for the Jebao MCP Series pumps.
10. Garantia i Suport
For warranty information and technical support, please contact your retailer or visit the official Jebao weblloc web. Conserveu el rebut de compra com a comprovant de compra.
Oficial Weblloc: www.jebao.com