1. Introducció

This manual provides comprehensive instructions for the installation, operation, and maintenance of your MARSTEK Smart Circuit Breaker HF-00095. This device offers adjustable overvoltage, minvartage, and overcurrent protection, along with energy monitoring capabilities, to safeguard your electrical equipment.

2. Informació important de seguretat

Please read and understand all safety instructions before installing or operating the device. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Producte acabatview i Característiques

The MARSTEK Smart Circuit Breaker HF-00095 is designed to provide intelligent protection and monitoring for your electrical circuits. It features a digital display for real-time voltage and current, and allows for customizable protection settings.

Diagram showing the functions of the MARSTEK Smart Circuit Breaker HF-00095, including real-time voltage and current display, work indicator lights, 'SET' button for settings, up/down keys for value adjustment, and manual power off button.
This diagram illustrates the key components and functions of the circuit breaker:
  • Vol en temps realtage Visualització: Mostra el volum actualtage.
  • Real-Time Current Display: Mostra el corrent amperage.
  • Work Indicator Lights: Indicate operational status and protection events.
  • Botó SET: Long press to enter settings mode.
  • Tecles amunt i avall: Used to adjust overvoltage, minvartage, and overcurrent values.
  • Manual Power Off Button: Allows for manual disconnection of the circuit.

Les característiques clau inclouen:

4. Especificacions tècniques

Table showing technical parameters of the MARSTEK Smart Circuit Breaker, including supply terminals, rated supply voltage, frequency, setting ranges for over/undervoltage, voltage hysteresis, trip delay, accuracy, max operating voltage/current, altitude, function, humidity, ambient temperature, net weight, and size.
The following table details the technical specifications of the MARSTEK Smart Circuit Breaker HF-00095:
ParàmetreValor
Supply TerminalsN, L
Vol. d'oferta nominaltageAC 110V; DC 85-300V
Freqüència nominal40/50/60 / 70Hz
>U Setting Range (Overvoltage)AC130-300V; DC130-300V
<U Setting Range (Undervoltage)AC80-210V; DC85-210V
Voltage Histèresi5V
Overvoltage Retard del viatge0.5 s
Voltage Precisió<1%
Max. Operating Phase Voltage350 V
Màx. Corrent de funcionament40A/63A
Altitud≤2000m
FuncióProtecció contra llamps
Humitat relativa permesa≤50% at 40°C (Without Condensation)
Temperatura ambient-25 °C ~ +55 °C
Pes net159 g
Mida81 * 36 * 66 mm

5. Instal·lació i cablejat

Proper installation is crucial for the safe and effective operation of the MARSTEK Smart Circuit Breaker. Refer to the wiring diagram below and follow all safety precautions.

Wiring diagram and dimensional drawing for the MARSTEK Smart Circuit Breaker HF-00095, showing input (N, L) and output (N, L) connections to a load, along with physical dimensions in inches.
This diagram illustrates the correct wiring connections for the device. Connect the incoming neutral (N) and live (L) wires to the "IN" terminals. Connect the outgoing neutral (N) and live (L) wires from the "OUT" terminals to your protected load. Ensure all connections are secure. The dimensional drawing provides physical measurements for installation planning.

Passos d'instal·lació:

  1. Desconnexió d'alimentació: Before starting any electrical work, ensure all power to the circuit is completely disconnected at the main service panel. Verify with a voltage provador.
  2. Muntatge: Mount the circuit breaker securely in a suitable electrical enclosure or panel. The device is designed for DIN rail mounting or screw mounting.
  3. Cablejat d'entrada: Connect the incoming Neutral (N) wire to the terminal marked 'N IN' and the incoming Live (L) wire to the terminal marked 'L IN'.
  4. Cablejat de sortida: Connect the outgoing Neutral (N) wire from the terminal marked 'N OUT' and the outgoing Live (L) wire from the terminal marked 'L OUT' to the load you wish to protect.
  5. Connexions segures: Ensure all terminal screws are tightened securely to prevent loose connections, which can cause overheating or intermittent operation.
  6. Restauració d'energia: Once all connections are verified and secure, restore power to the circuit at the main service panel.

6. Operation and Parameter Settings

Upon power-up, the device will display real-time voltage and current. You can adjust the protection parameters to suit your specific needs.

Adjusting Protection Parameters:

  1. Introduïu la configuració: Premeu llargament el botó SET button until the display changes, indicating entry into the settings menu.
  2. Paràmetres de navegació: Utilitza el Up () i Avall () buttons to cycle through the available parameters (e.g., overvoltage trip value, undervoltage trip value, overcurrent trip value, recovery delay time).
  3. Select Parameter: Premeu el botó SET button briefly to select the currently displayed parameter for adjustment.
  4. Ajusta el valor: Utilitza el Up () i Avall () buttons to change the parameter's value.
  5. Confirm and Exit: Premeu SET again to confirm the new value and move to the next parameter. To exit the settings menu at any time, long press the SET botó.

Default Protection Settings:

Automatic Reset Function:

In the event of an overvoltage, minvartage, or overcurrent condition, the circuit breaker will automatically cut off power to protect the connected load. After a default delay of 30 seconds, the device will attempt to restore power. If the fault condition persists, it will remain disconnected and attempt to reset again after another delay.

Diagram illustrating the automatic reset process of the circuit breaker: Overvoltage/Undervoltage/Overcurrent circuit cut-off, followed by a 30-second default delay, then circuit reset automatically after 30 seconds, and if abnormality persists, it continues to wait.
This diagram explains the automatic reset sequence:
  1. Upon detection of overvoltage, minvartage, or overcurrent, the circuit is cut off.
  2. A default delay of 30 seconds begins.
  3. After 30 seconds, the circuit attempts to reset automatically. If the abnormality is resolved, power is restored. If the abnormality persists, the device continues to wait before another reset attempt.

7. Manteniment

The MARSTEK Smart Circuit Breaker HF-00095 requires minimal maintenance to ensure optimal performance and longevity.

8. Solució De Problemes

If you encounter issues with your MARSTEK Smart Circuit Breaker, refer to the following troubleshooting guide:

9. Garantia i Suport

For detailed warranty information regarding your MARSTEK Smart Circuit Breaker HF-00095, please refer to the product packaging or visit the official MARSTEK weblloc.

For technical support, troubleshooting assistance, or any other inquiries, please contact MARSTEK customer service through their official contact channels, which can typically be found on their webdocumentació del lloc o del producte.

Documents relacionats - HF-00095

Preview Instruccions per utilitzar Venus amb Shelly Pro 3 EM
Una guia sobre com connectar i utilitzar el dispositiu Venus amb el Shelly Pro 3 EM, que detalla els passos per a la configuració de xarxa, la configuració del port i la selecció del tipus de mesurador a través de l'aplicació Marstek.
Preview MARSTEK CT002 Three-Phase Energy Meter User Manual and Technical Specifications
Comprehensive user manual and technical specifications for the MARSTEK CT002 three-phase energy meter. Covers product overview, installation guide, technical details, safety precautions, app integration, and warranty information.
Preview Manual d'usuari del comptador intel·ligent MARSTEK CT001
User manual for the MARSTEK CT001 Smart Meter, detailing installation, app usage, specifications, and safety guidelines for home energy monitoring.
Preview Manual d'usuari de MARSTEK VENUS - C/E: Guia d'instal·lació, funcionament i manteniment
Manual d'usuari complet per al sistema d'emmagatzematge d'energia acoblat a CA MARSTEK VENUS - C/E. Cobreix tot el producteview, instal·lació, control d'aplicacions, manteniment, resolució de problemes, especificacions tècniques i informació de seguretat per als models Venus-C (2.5 kWh) i Venus-E (5 kWh).
Preview Marstek Venus E Batterij & CT003 Meter Installatiehandleiding
Gedetailleerde instaliehandleiding per a Marstek Venus E thuisbatterij en de CT003 P1-poort slimme meterlezer, inclosa la configuració de l'aplicació, les actualitzacions de firmware i la integració de slimme meters.
Preview Manual d'usuari de la central elèctrica portàtil MARSTEK M2200
Manual d'usuari complet per a la central elèctrica portàtil MARSTEK M2200, que detalla les seves característiques, especificacions, mètodes de càrrega, instruccions d'ús, resolució de problemes, pautes de seguretat i informació sobre la garantia.