Introducció
This manual provides instructions for the installation and maintenance of your SRAM XX/XX SL Power Meter Cover. This product is designed as a replacement battery lid and cover for compatible SRAM XX/XX SL Power Meter spiders, ensuring the protection of the power meter's internal components.
Contingut del paquet
Before proceeding with installation, please verify that all components are present:
- 1x Power Meter Battery Lid and Cover
- 1x rentadora
- 1x junta tòrica
- 1x Primavera

Figure 1: SRAM XX/XX SL Power Meter Cover. This image displays the black, circular replacement cover for the power meter battery compartment.
Instruccions d'instal·lació
This replacement cover is compatible with SRAM Power Meter spiders FC-XX-P-D1 and FC-XX-SLP-D1.
- Elimina la coberta existent: Carefully unscrew and remove the old battery cover from your SRAM XX/XX SL Power Meter spider.
- Inspeccioneu el compartiment de la bateria: Ensure the battery compartment is clean and free of debris.
- Install O-ring and Spring: Place the O-ring into its designated groove on the new cover or power meter body (refer to your power meter's original manual for exact placement). Insert the spring into the battery compartment, ensuring it makes proper contact with the battery.
- Posició de la volandera: If applicable, place the washer as per your power meter's original design.
- Attach New Cover: Align the new SRAM XX/XX SL Power Meter Cover with the threading on the power meter spider. Gently screw the cover into place.
- Estrenyeu bé: Hand-tighten the cover until it is snug. Avoid over-tightening, as this can damage the threads or the O-ring, compromising the seal.
Nota important: This replacement cover is designed to fit the threading of the specified power meters. It does not include an internal adjustment screw, which may be present in some original SRAM battery covers. Please ensure this replacement meets your specific needs before installation.
Manteniment
- Inspecció periòdica: Periodically check the cover for any signs of damage, cracks, or wear.
- O-ring Condition: Ensure the O-ring is clean and free from nicks or tears to maintain a watertight seal. Replace the O-ring if it appears damaged or brittle.
- Neteja: Clean the cover with a soft, damp cloth. Avoid using harsh chemicals or abrasive materials that could damage the finish or material.
Resolució de problemes
| Problema | Causa possible | Solució |
|---|---|---|
| Cover does not fit or thread properly. | Incorrect model compatibility or cross-threading. | Verify your power meter model (FC-XX-P-D1 or FC-XX-SLP-D1). Ensure the cover is aligned correctly before tightening. Do not force. |
| Water ingress into battery compartment. | Damaged or improperly seated O-ring; cover not tightened sufficiently. | Inspect O-ring for damage and proper seating. Ensure cover is hand-tightened securely. |
| Power meter not functioning after cover replacement. | Battery issues, or internal component not properly engaged. | Check battery orientation and charge. Ensure the spring is correctly positioned to make contact. Note that this cover does not include an internal adjustment screw if your original cover had one. |
Especificacions
- Marca: SRAM
- Número de model: 107640
- Compatible Power Meters: FC-XX-P-D1, FC-XX-SLP-D1
- Color: Negre
- Material: Multi
- Components inclosos: Battery Lid and Cover, Washer, O-ring, Spring
- Dimensions del producte: Approximately 6.5 x 6.5 x 3 inches (Packaging dimensions)
- Pes de l'article: Approximately 12.8 ounces (Packaging weight)
Garantia i Suport
For warranty information or technical support regarding your SRAM product, please refer to the official SRAM weblloc web o poseu-vos en contacte amb el vostre distribuïdor autoritzat de SRAM. Conserveu el comprovant de compra per a reclamacions de garantia.
Oficial de SRAM Weblloc: www.sram.com