Primera alerta SMI105-AC

First Alert SMI105-AC Hardwire Smoke Alarm with 10-Year Battery Backup User Manual

Model: SMI105-AC

Marca: First Alert

Introducció

The First Alert SMI105-AC Interconnect Hardwire Smoke Alarm with 10-Year Battery Backup utilizes First Alert's Precision Detection advanced sensing technology. This alarm is designed to meet new industry standards, reducing nuisance alarms from cooking while providing early warning in the event of a home fire emergency. Its interconnectivity feature allows multiple compatible alarms to sound simultaneously throughout your home. The integrated 10-year battery backup ensures continuous protection even during power outages.

First Alert SMI105-AC Smoke Alarm with 10-Year Battery Backup

Imatge: Frontal view of the First Alert SMI105-AC smoke alarm, highlighting the 10-year battery backup feature.

Informació de seguretat

  • ADVERTIMENT: This unit is locked with no serviceable parts. The backup battery is not replaceable. If power is interrupted and the backup battery is dead or missing, maintenance and testing must be performed as indicated below. Exposure to high or low temperature or high humidity may reduce battery life.
  • IMPORTANT: This unit can only be interconnected with other compatible smoke, CO, and/or heat alarms up to a maximum limit of 18 total, of which 12 can be smoke alarms. Refer to the user's manual for detailed instructions.
  • IMPORTANT: This smoke alarm contains a maximum of 1.0 microcuries (37KBQ) of Americium 241, a radioactive material distributed under U.S. NRC License No. 12-23809-01E and is made in compliance with U.S. NRC safety criteria in 10CFR32.27. The purchaser is exempt from any regulatory requirements.

Contingut del paquet

Your First Alert SMI105-AC smoke alarm package should include the following items:

  • Unitat d'alarma de fum First Alert SMI105-AC
  • Suport de muntatge
  • Wire Harness (Easy Adapter Plug)
  • Cargols de muntatge
  • Manual d'usuari
First Alert SMI105-AC Smoke Alarm Package Contents

Image: The smoke alarm unit, mounting bracket, wire harness, and screws included in the package.

Configuració i instal·lació

Follow these steps for proper installation of your First Alert SMI105-AC smoke alarm:

  1. Apagueu l'alimentació: Before beginning any electrical work, ensure the power to the circuit where you will install the alarm is turned off at the main breaker.
  2. Remove Old Alarm (if applicable): Carefully remove any existing smoke alarm from its mounting bracket and disconnect its wiring.
  3. Instal·leu el suport de muntatge: Secure the new mounting bracket to the electrical box on your ceiling or wall using the provided screws.
  4. Connecteu el cablejat: Connect the wire harness from the alarm to your home's electrical wiring. Match black to line, white to neutral, and orange to interconnect (if connecting multiple alarms). Ensure all connections are secure.
  5. Activate Battery Backup: Remove the clear plastic pull tab from the side of the alarm to activate the internal 10-year battery backup.
  6. Connecteu la unitat d'alarma: Align the smoke alarm unit with the mounting bracket and twist clockwise until it locks securely into place.
  7. Restaura l'alimentació: Turn the power back on at the main breaker.
  8. Alarma de prova: Press and hold the 'Test/Silence' button on the front of the alarm until it sounds. This confirms proper operation.
Man installing First Alert smoke alarm on ceiling

Image: A man installing the First Alert SMI105-AC smoke alarm on a ceiling, demonstrating the hardwire connection process.

Video: SMI105-AC Overview Video. This video provides an overview of the First Alert SMI105-AC smoke alarm, highlighting its features, installation process, and testing procedures.

Instruccions de funcionament

The First Alert SMI105-AC smoke alarm is designed for simple operation and clear alerts:

  • Botó de prova/silenci: Press the large button on the front of the alarm to test its functionality. If the alarm is sounding due to a non-emergency (e.g., cooking smoke), pressing this button will temporarily silence it.
  • Alarm Guide:
    • 3 bips: Indicates a smoke alarm.
    • 3 Chirps every Minute: Indicates a malfunction. Replace the alarm.
    • 5 Chirps every Minute, LED Flashes 2 sec on/2 sec off: Indicates low battery. Replace the alarm.
    • 5 Chirps every Minute, 5 LED Flashes: Indicates end-of-life. Replace the alarm.
Man testing First Alert smoke alarm

Image: A man testing the smoke alarm by pressing the test/silence button on the installed unit.

Manteniment

Regular maintenance ensures the longevity and proper function of your smoke alarm:

  • Neteja: Gently vacuum or use clean compressed air to remove accumulated dust monthly. Avoid using water, cleaners, or solvents, as these may damage the unit.
  • Prova: Press the test button after installation, weekly, and after cleaning to check all alarm functions.
  • Substitució: Replace the alarm unit at least every 10 years from the manufactured date. The alarm will provide an end-of-life warning (5 chirps every minute, 5 LED flashes) when it's time for replacement.

Resolució de problemes

If your smoke alarm is behaving unexpectedly, refer to the Alarm Guide in the Operating Instructions section for common alerts and their meanings. Ensure regular cleaning and testing are performed. If a malfunction or end-of-life warning persists, the unit should be replaced.

Especificacions

CaracterísticaDetall
Número de modelSMI105-AC
Font d'alimentacióHardwire (120V AC ~ 60 Hz, 0.05A) with 10-Year Battery Backup
Tipus de sensorIonization (Precision Detection)
Sensibilitat al fum0.95%/ft. obs ± 25%
Dimensions del producte5.6 "P x 5.6" W x 2" H
Pes de l'article0.7 lliures (11.2 unces)
Humitat de funcionament10-95% HR
FabricantResideu
UPC029054022615
Components inclososEasy Adapter Plug

Garantia i Suport

For customer service or warranty inquiries, please contact:

Equip d'atenció al client: 1-800-323-9005

Fabricant: Resideo Technologies, Inc. i els seus afiliats

Adreça: 1301 Joe Battle, El Paso, TX, 79936 USA

Weblloc: firstalert.com

Documents relacionats - SMI105-AC

Preview Manuals d'usuari dels detectors de fum i monòxid de carboni First Alert
Manuals d'usuari complets per a l'alarma de fum amb cable fix First Alert 9120LBLA i l'alarma de monòxid de carboni endollable First Alert CO615A, que cobreixen la instal·lació, el funcionament, el manteniment, la seguretat i la resolució de problemes.
Preview Manual d'usuari de l'alarma de fum First Alert SA520A: instal·lació i funcionament
Manual d'usuari complet per al detector de fum First Alert SA520A. Aprèn sobre la seva alimentació de CA amb bateria de reserva, les funcions d'interconnexió sense fil, els passos d'instal·lació, el manteniment i consells importants de seguretat contra incendis per a l'alerta primerenca i la protecció de la llar.
Preview Manual d'usuari de l'alarma de fum i monòxid de carboni First Alert SC7010BV
Manual d'usuari complet per a l'alarma de fum i monòxid de carboni alimentada per corrent altern First Alert SC7010BV, que detalla la instal·lació, el funcionament, el manteniment, les funcions de seguretat i la resolució de problemes.
Preview First Alert 9120/9120B AC Powered Smoke Alarm User Manual
Comprehensive user manual for First Alert and BRK 9120 and 9120B AC-powered ionization smoke alarms with battery backup. Covers installation, operation, maintenance, features, troubleshooting, and fire safety tips.
Preview Manual d'usuari de l'alarma de fum i monòxid de carboni First Alert SMCO100V-AC
Comprehensive user manual for the First Alert SMCO100V-AC Smoke & Carbon Monoxide Alarm, detailing installation, operation, features, maintenance, and safety guidelines for residential use.
Preview Manual d'usuari de l'alarma de fum i monòxid de carboni First Alert SC7010B
Manual d'usuari complet per a l'alarma de fum i monòxid de carboni amb alimentació de CA First Alert SC7010B. Cobreix la instal·lació, les característiques, el funcionament, el manteniment, la resolució de problemes, la informació normativa i la garantia.