1. Introducció
Welcome to the user manual for your new ACONEE PC0N 19 SEER Inverter Smart Mini Split AC/Heating System. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your system. Please read it thoroughly before use and retain it for future reference.
2. Informació de seguretat
Seguiu sempre les precaucions de seguretat següents per evitar lesions o danys a la unitat.
Seguretat general
- Assegureu-vos que la font d'alimentació coincideixi amb les especificacions de la unitat.
- No intenteu reparar o modificar la unitat vosaltres mateixos. Poseu-vos en contacte amb personal de servei qualificat.
- Mantingueu els nens i les mascotes allunyats de la unitat durant el funcionament.
Seguretat elèctrica
- No opereu amb les mans mullades.
- Desconnecteu la unitat abans de netejar-la o fer-ne el manteniment.
- Assegureu-vos una correcta connexió a terra.
3. Components del producte
Your ACONEE Mini Split AC/Heating System includes the following main components:
- 1 x Wall mount air handler (Indoor Unit)
- 1 x Outdoor condenser (Outdoor Unit)
- 1 x Pre-flared and insulated copper line set
- 1 x Communication wires
- 1 x Drainage extension with small accessories
- 1 x comandament a distància

Imatge: Més deview of the ACONEE Mini Split AC/Heating System, showing the indoor unit, outdoor unit, remote control, and various installation accessories including copper lines, communication wires, and drainage extension.
4. Configuració i instal·lació
Installation of this mini-split system requires professional knowledge and tools. It is highly recommended to have a certified HVAC technician perform the installation to ensure proper function and safety. Incorrect installation can lead to refrigerant leaks, electrical shock, or fire.
Llista de verificació prèvia a la instal·lació
- Comproveu la font d'alimentació voltage (115 volts).
- Ensure adequate space for both indoor and outdoor units, allowing for proper airflow and maintenance access.
- Confirm all included components are present.
- Acquire necessary tools, including a vacuum pump and gauges for line clearing.
Passos d'instal·lació (més enllà)view)
- Col·locació de la unitat interior: Select a suitable wall location, ensuring it is strong enough to support the unit's weight and allows for proper air distribution.
- Col·locació de la unitat exterior: Choose a stable, level surface outdoors, away from direct sunlight or obstructions, with sufficient clearance for airflow.
- Connexió del conjunt de línies: Connect the pre-flared copper line set between the indoor and outdoor units. Ensure connections are tight to prevent refrigerant leaks.
- Cablejat elèctric: Connect communication wires and power supply according to the wiring diagram provided in the full installation manual. This step requires a qualified electrician.
- Aspirar les línies: Evacuate the refrigerant lines using a vacuum pump to remove air and moisture. This is a critical step for system efficiency and longevity.
- Alliberament de refrigerant: Once lines are vacuumed, release the pre-charged R-32 refrigerant from the outdoor unit into the system.
- Connexió de drenatge: Connect the drainage extension to the indoor unit's condensate drain to ensure proper water removal.
- Comprovació de fuites: Feu una comprovació exhaustiva de fuites a totes les connexions.

Image: A diagram illustrating the dimensions of the indoor and outdoor units, and the connection of the pre-flared and insulated copper line set, communication wires, and drainage extension. This image provides a visual guide for component placement and connection.
5. Instruccions de funcionament
Your ACONEE Mini Split system offers multiple operating modes and smart control options.
Mètodes de control
- Comandament a distància: Use the included wireless remote for direct control of modes, temperature, fan speed, and other functions.
- Aplicació per a telèfon intel·ligent: Download the dedicated app to control the unit remotely via Wi-Fi. This allows control from anywhere with an internet connection.
- Control de veu: Compatible amb Alexa i Google Assistant per a ordres de veu pràctiques.

Image: Depicts the smartphone app interface for controlling the ACONEE Mini Split system, alongside an Amazon Echo device, illustrating its compatibility with Alexa for voice control. This highlights the smart control features.
Modes de funcionament
The system features 5 primary working modes:
- Mode automàtic: Automatically selects cooling or heating based on the set temperature and ambient room temperature.
- Mode fresc: Provides cooling to lower the room temperature. Can cool down to 60°F.
- Mode de calor: Provides heating to raise the room temperature. Can heat up to 89°F.
- Mode sec (deshumidificació): Reduces humidity in the room, removing up to 36 pints per day.
- Mode de ventilador: Circulates air without cooling or heating. Adjustable fan speeds (Low, Medium, High, Auto).

Image: Illustrates the fast cooling and heating capabilities of the ACONEE Mini Split, showing air flow for cooling down to 60°F and heating up to 89°F. Two individuals are shown comfortably in a room, one using a laptop and the other drinking a beverage, demonstrating the system's effectiveness.
Funcions especials
- Mode de repòs: Adjusts temperature and fan speed for comfortable sleep, often increasing temperature slightly during cooling or decreasing during heating over time. Operates quietly at 27 dB.
- Mode ECO: Optimizes operation for energy efficiency, reducing power consumption.
- Funció iFEEL: The remote control has a temperature sensor that allows the unit to adjust the temperature based on the remote's location, providing more precise comfort.
- Funció turbo: Provides rapid cooling or heating to quickly reach the desired temperature.

Image: Shows a person sleeping peacefully, with arrows indicating gentle airflow from the indoor unit. Text highlights the quiet operation at 27 dB and the "Sleep Mode" feature, emphasizing a quiet and cozy environment.
6. Manteniment
Regular maintenance ensures optimal performance and extends the lifespan of your ACONEE Mini Split system.
Neteja de filtres
The indoor unit features a washable filter. Clean the filter regularly (e.g., every 2-4 weeks, depending on usage) to maintain air quality and efficiency.
- Obriu el panell frontal de la unitat interior.
- Traieu els filtres d'aire.
- Wash filters with lukewarm water and mild detergent.
- Esbandiu-ho bé i deixeu-ho assecar completament a l'aire abans de tornar-ho a col·locar.

Imatge: Un retall view of the indoor unit showing the "Distributed Healthy Filter System." It highlights the top-opened filter and various healthy filters including Silver Ion, Active Carbon, and Catechin filters, as well as a 6-in-1 filter system (Photocatalyst, Active Carbon, Anti-dust static, Catechin, Silver Ion, Vitamin C). This illustrates the multi-stage filtration for improved air quality.
Funció d'auto-neteja
The unit has a self-cleaning feature that operates at 134.6°F (57°C) to clean the interior coil and prevent mold and bacteria buildup. Refer to your remote control or app instructions to activate this function.
Outdoor Unit Maintenance
- Mantingueu la zona al voltant de la unitat exterior neta de deixalles, fulles i neu per garantir un flux d'aire adequat.
- The outdoor unit features automatic defrost to prevent ice buildup in cold weather, increasing energy efficiency.
- Periodically inspect the outdoor coil for dirt and clean gently with water if necessary.
7. Solució De Problemes
Abans de contactar amb l'atenció al client, consulteu els següents problemes i solucions habituals:
| Problema | Causa possible | Solució |
|---|---|---|
| La unitat no s'encén. | No hi ha subministrament elèctric; s'ha saltat l'interruptor. | Comproveu la connexió d'alimentació; reinicieu l'interruptor automàtic. |
| Refrigeració/calefacció insuficient. | Dirty air filter; blocked outdoor unit; incorrect mode setting; low refrigerant. | Clean air filter; clear obstructions from outdoor unit; select correct mode; contact technician for refrigerant check. |
| Soroll inusual. | Peces soltes; objecte estrany al ventilador; unitat no anivellada. | Inspect for loose parts; remove foreign objects; ensure unit is level. If noise persists, contact support. |
| Fuga d'aigua de la unitat interior. | Canonada de desguàs obstruïda; instal·lació incorrecta. | Reviseu i netegeu la canonada de desguàs; contacteu amb l'instal·lador per a la seva inspecció. |
| El comandament a distància no funciona. | Piles gastades; obstrucció entre el comandament a distància i la unitat. | Canvieu les piles; elimineu els obstacles. |
8. Especificacions
| Característica | Detall |
|---|---|
| Número de model | PC0N |
| Capacitat de refrigeració | 9000 BTU (10000 unitats tèrmiques britàniques) |
| Valoració SEER | 19 VEURE |
| Voltage | 115 Volts |
| Nivell de soroll (interior) | 34 dB (as low as 27 dB in Sleep Mode) |
| Tipus de refrigerant | R-32 |
| Dimensions del producte (unitat interior) | 34.84 "P x 14.4" W x 10.94" H |
| Pes de l'article | 23.8 lliures |
| Àrea de cobertura recomanada | Fins a 450 peus quadrats |
| Característiques especials | Inverter Compressor, Remote Controlled, WiFi Enabled, Heating And Cooling Function, Self-Cleaning, Auto Defrost |
9. Garantia i Suport
ACONEE provides the following warranty and support for your product:
- Garantia: 2 any de garantia.
- Manteniment: 12 Months Free Maintenance.
- Devolucions: 30 days Unreasonable Return policy.
- Substitució de peces: Disponible.
- Technology Support: Your doubts and questions will be responded to within 24 hours.

Image: Displays information about ACONEE's customer support, including email support within 12 hours, 30 days unreasonable return, and 12 months free maintenance and technology support. This reinforces the brand's commitment to customer service.