ProCom MN300TBA-B

ProCom MN300TBA-B Ventless Natural Gas Blue Flame Space Heater Instruction Manual

1. Introducció

This manual provides essential information for the safe and efficient operation of your ProCom MN300TBA-B Ventless Natural Gas Blue Flame Space Heater. Please read all instructions carefully before installation and use. Retain this manual for future reference.

ProCom MN300TBA-B Ventless Natural Gas Blue Flame Space Heater

Figure 1: ProCom MN300TBA-B Ventless Natural Gas Blue Flame Space Heater.

2. Informació important de seguretat

ADVERTÈNCIA: La instal·lació, l'ajustament, l'alteració, el servei o el manteniment inadequats poden causar danys a la propietat, lesions o la mort. Llegiu atentament les instruccions d'instal·lació, funcionament i manteniment abans d'instal·lar o donar servei a aquest equip.

  • This heater is hot while in operation. Do not touch the hot surfaces. Keep children, clothing, and furniture away.
  • Mantingueu nets el cremador i el compartiment de control.
  • This heater shall not be installed in a bedroom or a bathroom.
  • No emmagatzemeu ni utilitzeu gasolina o altres vapors i líquids inflamables a prop d'aquest o qualsevol altre aparell.
  • Ensure adequate ventilation. Ventless gas heaters consume oxygen from the room.
  • A built-in Oxygen Depletion Sensor (ODS) system immediately shuts down the heater if carbon monoxide or lack of oxygen is detected.
  • For your safety, always install a carbon monoxide detector in your home.

3. Característiques del producte

The ProCom MN300TBA-B heater offers efficient heating with several key features:

  • Tecnologia: Produces 30,000 Maximum BTU using Natural Gas, heating up to 1400 sq. ft.
  • Fiable: Features a thermostat control with High/Medium/Low settings for optimal heat flow.
  • Elegant: Slim and modern profile, suitable for wall mounting or floor placement with included base feet.
  • Segur: Equipped with a push-button ignition and a built-in pilot Oxygen Depletion Sensor (ODS) for safety. ANSI Certified.
  • Convenient: Operates without electricity, making it suitable for power outages.
ProCom Heater Features: 30,000 BTU, No Venting, Natural Gas, No Electricity, Piezo Ignition, Thermostat Mode

Figure 2: Key features of the ProCom Ventless Heater.

ProCom Heater includes Base Feet, Wall Bracket, Oxygen Depletion Sensor, Operates on Natural Gas Only

Figure 3: Included components and fuel type.

4. Configuració i instal·lació

This heater can be installed as a wall-mounted unit or placed on the floor using the provided base feet. Professional installation is recommended for gas connections.

4.1 Desembalatge i inspecció

Carefully remove the heater from its packaging. Inspect for any damage. Ensure all components, including base feet and wall mount hardware, are present.

4.2 Consideracions de col·locació

  • Ensure the heater is placed on a level, stable surface if using base feet.
  • Maintain proper clearances from combustible materials as specified in the full installation instructions.
  • Do not install in a bedroom or bathroom.
  • Ensure adequate ventilation in the room where the heater is installed.

4.3 Opcions de muntatge

The heater comes with hardware for both wall mounting and floor placement.

  • Muntatge en paret: Use the included wall bracket and fasteners to securely attach the heater to a suitable wall surface.
  • Base Feet: Attach the provided base feet to the bottom of the heater for freestanding operation.
ProCom Heater showing blue flame technology and included base feet

Figure 4: Heater with base feet, highlighting blue flame technology.

ProCom Heater dimensions: 24 inches H, 27 inches L, 8 inches D

Figura 5: Dimensions del producte per a la planificació de la instal·lació.

4.4 Connexió de gas

This heater operates on Natural Gas. Connect the heater to your natural gas supply line according to local codes and manufacturer instructions. It is highly recommended to have a qualified professional perform the gas connection to ensure safety and proper function.

5. Instruccions de funcionament

Follow these steps to operate your ProCom Ventless Natural Gas Heater:

5.1 Encesa

  1. Assegureu-vos que el subministrament de gas estigui activat.
  2. Turn the thermostat control knob to the 'PILOT' setting.
  3. Push and hold the control knob in while simultaneously pressing the ignitor button repeatedly until the pilot flame lights.
  4. Continue to hold the control knob in for approximately 30-60 seconds after the pilot lights to allow the thermocouple to heat up. Release the knob slowly. If the pilot goes out, repeat the process.

5.2 Adjusting Heat (Thermostat Control)

Once the pilot is lit, turn the thermostat control knob to your desired heat setting. The heater offers High, Medium, and Low settings to maintain a comfortable room temperature.

5.3 Tancament

  1. To turn off the main burner, turn the thermostat control knob to the 'OFF' position. The pilot light will remain lit.
  2. To completely shut down the heater (including the pilot light), turn the control knob to 'OFF PILOT'.
  3. For extended periods of non-use, it is recommended to turn off the main gas supply valve to the heater.
Close-up of ProCom Heater's ignitor button and thermostat control dial

Figure 6: Ignitor and Thermostat Controls.

Video 1: Product Summary Video demonstrating general features and operation.

6. Manteniment

Un manteniment regular garanteix la longevitat i el funcionament segur del vostre escalfador.

  • Neteja: Keep the burner and control compartment clean. Use a vacuum cleaner to remove dust and lint from the air intake and outlet grilles.
  • Pilot Light and Burner Inspection: Periodically check the pilot light and main burner flames for proper appearance (blue, steady flame). Refer to the full manual for detailed flame characteristics.
  • Connexions de gas: Annually inspect all gas connections for leaks using a soap solution. Never use an open flame to check for gas leaks.
  • Servei professional: It is recommended to have your heater inspected by a qualified service technician at least once a year.

7. Solució De Problemes

If you encounter issues with your heater, refer to the following common troubleshooting steps. For persistent problems, contact a qualified service technician.

ProblemaCausa possibleSolució
El pilot no s'encendràNo gas supply; Air in gas line; Pilot orifice cloggedCheck gas valve; Purge air from line; Clean pilot orifice
El pilot no es mantindrà encèsThermocouple faulty; Pilot flame too smallReplace thermocouple; Adjust pilot flame
El cremador principal no s'encendràPilot not lit; Thermostat set too low; Main burner orifice cloggedLight pilot; Adjust thermostat; Clean burner orifice
Heater produces odorNew unit burn-off; Dust/debris on burner; Inadequate ventilationAllow initial burn-off; Clean heater; Ensure proper ventilation

8. Especificacions

AtributDetall
MarcaProCom
Número de modelMN300TBA-B
Tipus de combustibleGas Natural
Sortida BTU30,000 BTU
Cobertura de calefaccióFins a 1400 peus quadrats
Característica especialAdjustable Temperature (Thermostat Control)
ColorBlanc
Factor de formaPedestal (Floor Mount)
Tipus de muntatgeMuntatge a terra, muntatge a la paret
Dimensions del producte8 "P x 29" W x 28" H
Pes de l'article29.7 lliures
Tipus de cremadorFlama Blava
UPC848660008383

9. Garantia i assistència

For warranty information and customer support, please refer to the documentation included with your product or visit the official ProCom weblloc. Conserveu el rebut de compra per a reclamacions de garantia.

Documents relacionats - MN300TBA-B

Preview Manual d'usuari de la nova ràdio bidireccional Procom PRO-9900 AM/FM Citizens Band
Manual d'usuari de la ràdio bidireccional Procom NEW PRO-9900 AM/FM Citizens Band, que detalla les seves funcions, funcionament, característiques i especificacions tècniques per a un ús òptim.
Preview PROCOM Atlas Loud Mouth Digital Wireless Intercom User Manual
This user manual provides comprehensive information on the PROCOM Atlas Loud Mouth Digital Wireless Intercom, including its features, operation, specifications, safety guidelines, and FCC compliance.
Preview Escalfador de gas sense ventilació ProCom Heating: Manual d'ús i instal·lació
Guia completa per als escalfadors de gas sense ventilació ProCom Heating, que cobreix la instal·lació, el funcionament, la seguretat, el manteniment i la resolució de problemes dels models MN180TPA-B, ML150TPA-B, MN300TPA-B i ML250TPA-B.
Preview Manual d'ús i instal·lació del calefactor de paret de gas sense ventilació ProCom
Aquest manual proporciona instruccions de funcionament i instal·lació per als escalfadors de paret de gas sense ventilació ProCom, inclosos els models MN2PHG, MN2PTG, MN3PHG, MN3PTG, ML2PHG, ML2PTG, ML3PHG i ML3PTG. Cobreix les precaucions de seguretat, les característiques del producte, les especificacions, els procediments d'instal·lació, el funcionament, la resolució de problemes, les peces, els accessoris i la informació sobre la garantia.
Preview Manual de l'escalfador de llenya de gas sense ventilació ProCom Heating
This manual provides comprehensive installation, operation, safety, and maintenance instructions for ProCom Heating Vent-Free Gas Log Heater models PCNSD18T, PCNSD24TD, and PCNSD24M. Learn how to safely install and use your gas log heater.
Preview Manual d'instal·lació i funcionament de la xemeneia de gas sense ventilació ProCom Heating FBNSD28T
Manual complet d'ús i instal·lació per a la xemeneia de gas ProCom Heating FBNSD28T sense ventilació. Inclou pautes de seguretat, especificacions, procediments d'instal·lació, instruccions de funcionament, manteniment i resolució de problemes.