1. Introducció
The SINGCALL APE170 Water Leak Detector is designed to provide real-time monitoring for water leaks in your home or office. With its high sensitivity sensors and loud alarm, it helps prevent potential water damage by alerting you immediately when water is detected. This manual provides detailed instructions for the proper setup, operation, and maintenance of your water leak detector.
2. Característiques del producte
- Real-time Water Leak Monitoring: Detects water leaks instantly and triggers an alarm.
- Alta sensibilitat: Activates when two adjacent sensor feet or the two water drop sensors on top detect water.
- High-Intensity Alarm: Produces an alarm volume of up to 120dB to ensure timely alerts. The initial alarm lasts 15 seconds, followed by 2-second alarms every 15 seconds until dehydrated or manually stopped.
- Disseny impermeable IP65: Ensures stable and durable performance in wet environments.
- Fàcil operació: Simple battery installation and alarm cancellation via the [TEST] button.
3. Contingut del paquet
Si us plau, comproveu el contingut del paquet per assegurar-vos que hi hagi tots els elements:
- 2 x SINGCALL APE170 Water Leak Detectors
- 2 piles AAA (preinstal·lades)
- 1 x Opening Tool
- 1 x Manual d'usuari
4. Configuració
4.1 Instal·lació de la bateria
- Use the provided opening tool to gently open the cover of the water leak detector. Align the tool with the notch and spin it to separate the two halves.
- Locate the insulating sheet in the battery compartment. Pull out this sheet to activate the pre-installed AAA batteries.
- Align the indicator lines on the edge of the two halves and close the cover securely.

Figure 1: Opening the detector with the provided tool.

Figure 2: Removing the battery insulating sheet.
4.2 Recomanacions de col·locació
Place the water leak detector in areas prone to water leaks. The detector can detect water from both its bottom sensor feet and its top water drop sensors.
- Banys: Near toilets, sinks, showers, or bathtubs.
- Cuines: Under sinks, near dishwashers, or refrigerators.
- Bugaderies: Beside washing machines or utility sinks.
- Soterranis: In areas susceptible to flooding or pipe leaks.
- Altres àrees: Near water heaters, window sills, or any location where water leakage is a concern.

Figure 3: Recommended placement locations for the water leak detector.

Figura 4: Detallada view of the water leak sensors.
5. Instruccions de funcionament
5.1 Water Detection and Alarm
The SINGCALL APE170 Water Leak Detector is equipped with multiple sensors to detect water presence:
- The alarm will sound immediately if two or more adjacent sensor feet at the bottom of the device detect water overflow.
- The alarm will also activate if the two water drop sensors located on the top of the device are covered with water.
Upon detection, the device will emit a loud alarm (up to 120dB). The first alarm sequence will last for 15 seconds. If the water is not removed from the sensors, the alarm will sound again for 2 seconds every 15 seconds until the sensors are dry or the alarm is manually stopped.

Figure 5: The 120dB alarm is designed to be heard throughout your home.
5.2 Aturar l'alarma
Per aturar l'alarma:
- Remove the detector from the water source and dry the sensors completely. The alarm will cease once the sensors are dry.
- Alternatively, press the [TEST] button on the top of the detector to temporarily silence the alarm.
Video 1: Demonstration of the SINGCALL Water Leak Detector in action, showing placement, water detection, and alarm activation.
6. Manteniment
6.1 Neteja
Regularly inspect the sensor feet and the top water drop sensors for any dirt, dust, or debris that might interfere with detection. Clean them gently with a soft, dry cloth.
6.2 Substitució de la bateria
When the battery is low, the detector may emit a low battery warning (if applicable, refer to product specifications for specific low battery indicators). To replace the batteries:
- Use the opening tool to open the detector cover.
- Traieu les piles AAA velles.
- Introduïu dues piles AAA noves, assegurant-vos de la polaritat correcta (+/-).
- Tanqueu la coberta de manera segura.
7. Solució De Problemes
- Alarm not sounding when water is detected:
- Ensure the batteries are correctly installed and not depleted. Replace if necessary.
- Check that the sensor feet or top sensors are making proper contact with the water.
- Verify that the device is not damaged.
- Falses alarmes:
- Ensure the detector is placed on a completely dry surface.
- Clean the sensors to remove any moisture, dust, or debris that might be causing false readings.
8. Especificacions
| Número de model | APE170 |
| Marca | SINGCALL |
| Font d'alimentació | 2 piles AAA (incloses) |
| Voltage | 3 Volts |
| Nivell de soroll | Fins a 120 decibels |
| Tipus de muntatge | Muntatge al terra |
| La tecnologia de sensors | Sensor de contacte |
| Dimensions del producte | 3.54 x 2.36 x 2.95 polzades |
| Pes de l'article | 5.9 unces |
| Classificació impermeable | IP65 |
9. Garantia i Suport
For warranty information or technical support, please refer to the contact details provided on the product packaging or visit the official SINGCALL weblloc. Conserveu el rebut de compra per a reclamacions de garantia.