Introducció
The GREEN GT790 is a 100% electric, self-contained air conditioning unit designed for use in heavy, medium, and light-duty trucks, as well as construction and agricultural cabs. This innovative system integrates a condenser, compressor, and evaporator core into a single unit, providing efficient thermal comfort without relying on the vehicle's engine for power. It operates on 12 volts and delivers up to 12,000 BTU of cooling capacity.
Informació de seguretat
Llegiu atentament totes les instruccions de seguretat abans de la instal·lació i el funcionament. Si no seguiu aquestes instruccions, podeu patir danys materials, lesions o la mort.
- Ensure the unit is installed by a qualified professional to prevent electrical hazards and ensure proper functioning.
- Desconnecteu sempre l'alimentació abans de realitzar qualsevol manteniment o servei.
- Do not block air inlets or outlets on either the indoor or outdoor unit.
- Verify that the power supply matches the unit's requirements (12V, 30/40 amps).
- Keep the unit away from flammable materials and sources of heat.
- Ensure proper ventilation around the outdoor unit.
Components del producte acabatsview
The GREEN GT790 system consists of two primary units and essential accessories:
- Outdoor Unit (Red): Contains the condenser, compressor, and fan. Dimensions: 18 x 23 x 8 inches.
- Indoor Unit (White): Contains the evaporator core, fan, and control panel. Dimensions: 18 x 12 x 6 inches.
- Comandament a distància: Per a un funcionament convenient de la unitat.
- Connecting Hoses and Wiring: Required for linking the indoor and outdoor units and connecting to the power supply.





Configuració i instal·lació
The GT790 is a split system and requires professional installation. The following are general guidelines and critical steps:
- Selecció del lloc: Choose appropriate locations for both the outdoor (red) and indoor (white) units. Ensure adequate space for airflow and maintenance. The outdoor unit is typically mounted externally, and the indoor unit within the cab.
- Muntatge: Securely mount both units using appropriate hardware for the vehicle type. Ensure the mounting surfaces are strong enough to support the unit's weight (outdoor unit approx. 66.1 lbs).
- Connexió de la línia de refrigerant: Connect the refrigerant lines between the indoor and outdoor units. Ensure all connections are tight and leak-free.
- Connexió elèctrica: Connect the unit to a 12V DC power source capable of supplying 30-40 amps. Ensure proper wiring polarity and secure connections. It is recommended to connect directly to the battery with appropriate fusing.
- Add Refrigerant Oil: Before initial operation, it is crucial to add the proper amount of refrigerant oil to the system. Consult the specific installation guide provided with your unit for the correct type and quantity of oil. Failure to do so will void the warranty and can cause severe damage to the compressor.
- Vacuum and Charge: After connecting the refrigerant lines, the system must be evacuated to remove air and moisture, then charged with the correct type and amount of refrigerant. This step requires specialized equipment and expertise.
- Prova d'execució: After installation and charging, perform a test run to ensure all functions are operating correctly and there are no leaks.
For detailed installation diagrams and specific instructions, refer to the comprehensive installation manual included with your purchase.
Instruccions de funcionament
The GREEN GT790 can be operated via the control panel on the indoor unit or the included remote control.
Using the Control Panel (Indoor Unit)
The indoor unit features a digital display and several buttons for direct control:
- Botó d'encesa: Premeu per encendre o apagar la unitat.
- Botons de temperatura (+/-): Ajusteu la temperatura desitjada.
- Botó de velocitat: Cycle through fan speed settings (e.g., Low, Medium, High).
- Botó de mode: Select operating modes (if available, typically cooling only for this model).
Ús del comandament a distància
The remote control provides full functionality from a distance:
- Botó d'encendre (⏻): Encén o apaga la unitat.
- Temperatura+ / Temperatura-: Augmenta o disminueix la temperatura configurada.
- Speed+ / Speed-: Ajusta la velocitat del ventilador.
- Swing Flap: Activates or deactivates the 4-way swing function for air distribution.
- Mode Buttons (Strong, Standard, Sleep): Select pre-set operating modes for different comfort levels.
Ensure the remote control has fresh batteries and is pointed towards the indoor unit for optimal signal reception.
Manteniment
Regular maintenance ensures optimal performance and longevity of your GT790 A/C unit.
- Filtres d'aire nets: The indoor unit has air filters that should be cleaned regularly (e.g., monthly or as needed, depending on usage and environment). Remove the filters, wash them with mild soap and water, rinse thoroughly, and allow them to dry completely before reinserting.
- Check Condenser Coils (Outdoor Unit): Periodically inspect the condenser coils on the outdoor unit for dirt, leaves, or other debris. Clean them gently with a soft brush or vacuum cleaner. A clean coil ensures efficient heat exchange.
- Inspect Drainage: Ensure the condensate drain line from the indoor unit is clear and free of obstructions to prevent water leaks.
- Comproveu les connexions elèctriques: Annually, or if you notice any issues, have a qualified technician inspect all electrical connections for tightness and signs of wear.
- Refrigerant Oil Level: While the unit is a sealed system, if any service requiring opening the refrigerant lines is performed, ensure the proper amount of oil is added back into the system. This is typically done by a professional.
- Neteja general: Wipe down the exterior surfaces of both units with a soft, damp tela. No utilitzeu productes químics aggressivs ni netejadors abrasius.
For any complex maintenance or repairs, it is highly recommended to contact a certified HVAC technician.
Resolució de problemes
Aquesta secció ofereix solucions a problemes comuns que podeu trobar. Per a problemes que no figuren aquí, poseu-vos en contacte amb l'atenció al client.
| Problema | Causa possible | Solució |
|---|---|---|
| La unitat no s'encén. | No power supply; tripped fuse/breaker; remote control batteries dead. | Check power connections; reset fuse/breaker; replace remote control batteries. |
| La unitat funciona però no es refreda. | Dirty air filters; blocked outdoor unit; low refrigerant; incorrect mode setting. | Clean air filters; clear obstructions from outdoor unit; contact technician for refrigerant check; ensure unit is in cooling mode. |
| Flux d'aire feble. | Dirty air filters; fan speed set too low; blocked air vents. | Clean air filters; increase fan speed; clear any obstructions from vents. |
| Soroll inusual de la unitat. | Loose parts; debris in fan; unit not level. | Inspect for loose components; check for debris in fan blades; ensure unit is mounted level. If noise persists, contact support. |
| Fuita d'aigua de la unitat interior. | Clogged drain line; improper installation. | Clear the drain line; if problem persists, contact a professional for inspection. |
Especificacions
| Característica | Detall |
|---|---|
| Nom de marca | VERD |
| Informació del model | GT790 |
| Número de model de l'article | GT790 |
| Número de part | DS630051 |
| Pes de l'article | 66.1 lliures |
| Dimensions de la unitat exterior (L x A x A) | 18 x 23 x 8 polzades |
| Dimensions de la unitat interior (L x A x A) | 18 x 12 x 6 polzades |
| País d'origen | Xina |
| Consum anual d'energia | 950 watts |
| Nivell de soroll | 33 dB |
| Tipus d'instal·lació | Sistema dividit |
| Factor de forma | Gabinet |
| Característiques especials | Swing de 4 vies |
| Color | Red (Outdoor Unit) |
| Voltage | 12 Volts |
| Wattage | 950 watts |
| Tipus de combustible | Elèctric |
| Potència de refrigeració | 12000 unitats tèrmiques britàniques (BTU) |
| Components inclosos | Control remot |
Garantia i Suport
The GREEN GT790 Electric A/C Unit includes a 6 mesos de garantia from the date of purchase. This warranty covers manufacturing defects and ensures the unit performs as specified under normal operating conditions.
For technical assistance, troubleshooting, or warranty claims, please contact the seller, Qualy Air. Their support team is committed to providing responsive assistance to resolve any issues you may encounter.
Qualy Air Contact Information: Please refer to your purchase documentation or the seller's information on the platform where you purchased the product for direct contact details.
Note: The warranty may be voided if the unit is not installed by a qualified professional or if proper refrigerant oil is not added prior to initial operation.