Opengear CM8148-10G

Opengear CM8148-10G Device Server User Manual

1. Introducció

This manual provides essential information for the installation, operation, and maintenance of the Opengear CM8148-10G Device Server. The CM8148-10G is a robust console manager designed for data centers and enterprise networks, offering secure and reliable out-of-band management for critical infrastructure.

It facilitates remote access and management of serial console ports, ensuring business continuity even when the primary network is unavailable. This device integrates advanced security features and supports automation tools for efficient network management.

2. Producte acabatview

The Opengear CM8148-10G is a high-density console server, providing extensive connectivity options for various network devices. Its design emphasizes reliability, security, and ease of management.

Opengear CM8148-10G Device Server front view with 48 serial ports, console port, USB ports, and network uplinks.

Figure 1: Front panel of the Opengear CM8148-10G Device Server. This image displays the front panel of the Opengear CM8148-10G Device Server. It features 48 serial console ports, two USB ports, a console port, and four network uplink ports (two SFP+ and two RJ45). The device has a dark gray chassis with a red accent stripe.

Característiques principals:

  • 16, 32, or 96-port serial console server with Smart Out-of-Band™ capabilities.
  • Designed as a replacement for legacy terminal servers.
  • Enables Data Center automation with Python and Docker support.
  • Embedded physical security using a TPM 2.0 module.
  • Dual power supplies with independent monitoring for enhanced reliability.

3. Configuració

3.1 Desembalatge i inspecció

Carefully unpack the device server and its accessories. Inspect all components for any signs of damage. If any damage is found, contact your vendor immediately.

3.2 Instal·lació física

The CM8148-10G is designed for rack mounting. Secure the device in a standard 19-inch equipment rack using the provided mounting hardware. Ensure adequate airflow around the unit for proper cooling.

3.3 Connexió d'alimentació

Connect the two power supply units to independent power sources for redundancy. Use the provided power cords. Verify that the power indicator LEDs illuminate after connection.

3.4 Connexió de xarxa

Connect the device server to your network using the appropriate Ethernet or SFP+ uplink ports. It is recommended to connect to at least two network ports for redundancy and out-of-band access.

3.5 Connexions del port sèrie

Connect your target devices' serial console ports to the corresponding serial ports on the CM8148-10G using straight-through cabling. The device supports auto-discovery of serial settings and port labels to simplify configuration.

4. Instruccions de funcionament

4.1 Accés inicial

Access the device server's management interface via a web browser or SSH. Refer to the Opengear documentation for default IP addresses and login credentials. It is crucial to change default passwords immediately after initial access.

4.2 Configuració

Configure serial port settings, network parameters, user accounts, and security policies through the web interface. Utilize features like port auto-discovery to streamline the setup of connected devices.

4.3 Gestió remota

Use the CM8148-10G to remotely access and manage the console ports of connected devices. This allows for troubleshooting, configuration, and monitoring of your infrastructure from any location.

4.4 Automation Features

Leverage the device's support for REST API, Docker, and Python scripting to integrate with existing automation tools and workflows. This enables advanced management and orchestration capabilities.

5. Manteniment

5.1 actualitzacions de microprogramari

Regularly check the Opengear website for firmware updates. Applying updates ensures optimal performance, security patches, and access to new features. Follow the provided instructions for a safe update process.

5.2 Neteja

Keep the device server clean and free from dust. Use a soft, dry cloth for external cleaning. Ensure ventilation openings are not obstructed to maintain proper cooling.

5.3 Consideracions ambientals

Operate the device within its specified environmental conditions (temperature, humidity) to ensure longevity and reliable performance. Avoid exposing the unit to extreme conditions or direct sunlight.

6. Solució De Problemes

6.1 Problemes comuns

  • Sense energia: Verify power cord connections and check power sources. Ensure both power supplies are connected and their LEDs are active.
  • Problemes de connectivitat de xarxa: Check Ethernet cable connections, network configuration, and ensure the correct IP address is assigned. Verify network port status LEDs.
  • Cannot Access Serial Console: Confirm serial cable type (straight-through), correct port selection, and matching serial settings (baud rate, data bits, parity, stop bits) on both the device server and the connected equipment.
  • Login Problems: Double-check username and password. If forgotten, refer to the Opengear documentation for password recovery procedures or factory reset options (use with caution).

For more detailed troubleshooting, consult the comprehensive Opengear documentation available on their official support weblloc.

7. Especificacions

CaracterísticaDetall
MarcaOpengear
SèrieCM8100-10G
Número de modelCM8148-10G
Pes de l'article8 lliures
Dimensions del producte (LxWxH)10.5 x 17.3 x 1.8 polzades
FabricantOPENGEAR
ASINB0CY59R3YY
Data de primera disponibilitat15 de març de 2024

8. Garantia i Suport

For information regarding the product warranty, please refer to the official Opengear warranty policy available on their website or contact your authorized Opengear reseller. Technical support and additional resources, including detailed documentation and software downloads, can be found on the Opengear support portal.

It is recommended to register your product to receive updates and support notifications.

Documents relacionats - CM8148-10G

Preview Guia d'inici ràpid de l'Opengear Operations Manager 2200
Guia d'inici ràpid per a la instal·lació i configuració de la sèrie Opengear Operations Manager 2200, inclosos els models OM2216, OM2224-24E, OM2248 i les seves variants. Cobreix la configuració del maquinari, la configuració de xarxa i l'accés als dispositius.
Preview Opengear User Manual: Data Center and Remote Site Management
This comprehensive user manual from Opengear details the features and capabilities of their advanced product lines designed for data center and remote site management. It provides essential instructions for users responsible for evaluating, installing, operating, or managing Opengear appliances, covering installation, configuration, networking, security, and advanced features.
Preview Opengear User Manual: Data Center and Remote Site Management
Comprehensive user manual detailing the features and operation of Opengear's console servers, remote site managers, and infrastructure managers for data center and remote site management. Covers installation, configuration, security, and advanced functionalities.
Preview Opengear CM7116, CM7132, CM7148 Quick Start Guide
Quick start guide for Opengear CM7116, CM7132, and CM7148 console servers, covering installation, hardware connection, initial setup, serial and USB device configuration, user management, and accessing device consoles.
Preview Opengear Console Server User Guide
This user guide provides comprehensive instructions for installing, operating, and managing Opengear console servers, including models like ACM7000, IM7200, and CM7100. It covers system configuration, network setup, security features, and troubleshooting for IT infrastructure management.
Preview Opengear Operations Manager OM12xx/OM22xx Quick Start Guide
This Quick Start Guide provides basic installation and configuration instructions for the Opengear Operations Manager OM12xx and OM22xx series devices, including setup, login, and basic configuration steps.