1. Introducció
This manual provides comprehensive instructions for the installation, setup, operation, and maintenance of your Venstar T1050 Programmable Thermostat. The T1050 is a 5+2 day programmable thermostat designed for residential use, offering 2-stage calor i 2-stage cool capabilities. It is compatible with gas/electric systems, heat pumps, electric heat, and hydronic heat systems. Its features include auto changeover, a large electro-luminous display, and non-volatile memory to retain settings during power outages.
2. Informació de seguretat
ADVERTÈNCIA: Perill de descàrrega elèctrica
- Desconnecteu sempre l'alimentació del sistema de calefacció i refrigeració al fusible principal o al quadre de fusibles abans d'instal·lar o fer el manteniment del termòstat.
- Improper wiring can cause damage to the thermostat or the heating/cooling system.
- Si no esteu segurs de cap pas, la instal·lació l'ha de dur a terme un tècnic qualificat.
This thermostat operates on 24 Volts AC. Do not connect to line voltage (120V o 240V).
3. Producte acabatview
3.1 Característiques clau
- 5+2 Day Programmable with up to 4 Time Periods per day.
- Auto Changeover: Automatically switches between heating and cooling as needed.
- 2-Stage Calor/2-Stage Cool compatibility for gas/electrics, heat pumps, electric & hydronic heat.
- Dual-Set point with adjustable deadband.
- Setpoint adjustment range from 35° to 99° F, switchable to °C.
- Thermostat Locking: Set points can be restricted to authorized individuals.
- Thermoglow Continuously Lit Electro-luminous Display for clear visibility.
- Large number display, easy to operate and program.
- Configurable display shows both heating and cooling setpoints and room temperature simultaneously.
- All programming and setpoints stored in non-volatile memory, ensuring settings are never lost in power failure.
- Red/Green LED indicator shows whether the system is calling for Heating (Red) or Cooling (Green).
- 5-minute compressor time guard and adjustable cycle limit, overrideable for servicing.
- Meets California Residential Title 24.
3.2 Components i pantalla
The Venstar T1050 thermostat features a clean, ultra-white design with an intuitive interface. The front panel includes a large LCD display and soft-touch buttons for mode, fan, and temperature adjustments.

Figura 3.2.1: Frontal view of the Venstar T1050 Thermostat, displaying current time, room temperature (72°), cool setpoint (73°), heat setpoint (77°), and fan status. The display is electro-luminous for easy reading.

Figura 3.2.2: Detallada view of the thermostat's front panel, highlighting the large LCD screen and the 'Mode', 'Fan', and temperature adjustment buttons (up/down arrows).
The bottom of the thermostat features a small LED indicator that glows green when calling for cooling and red when calling for heating.
4. Instal·lació
IMPORTANT: Turn off power to the HVAC system at the circuit breaker before beginning installation.
4.1 Ubicació de muntatge
Install the thermostat on an inside wall, approximately 5 feet (1.5 meters) above the floor. Avoid locations near heat sources (lamps, sunlight, fireplaces), cold drafts (windows, doors), or areas with poor air circulation.
4.2 Removing Old Thermostat
- Ensure power to the HVAC system is OFF.
- Traieu la coberta del vostre termòstat antic.
- Take a picture of the existing wiring connections for reference.
- Label each wire with the terminal designation it was connected to (e.g., R, G, Y, W).
- Desconnecteu els cables i traieu la base antiga del termòstat de la paret.
4.3 Wiring the T1050
The T1050 is designed for 24V AC systems. Refer to the detailed wiring diagrams provided in the separate installation manual included with your product. The back of the thermostat provides access to the wiring terminals.

Figura 4.3.1: posterior view of the Venstar T1050 Thermostat, showing the internal circuit board and the designated areas for wiring connections. This view és crucial per a una instal·lació correcta.
4.4 Muntatge del termòstat
- Pull the thermostat wires through the opening in the new thermostat base.
- Secure the thermostat base to the wall using the provided anchor screws.
- Connect the wires to the appropriate terminals on the T1050 base, matching the labels from your old thermostat.
- Once wired, snap the thermostat front onto the base.
- Restableix l'alimentació del sistema de climatització a l'interruptor.

Figure 4.4.1: Dimensional drawing of the Venstar T1050 Thermostat, showing its compact size (approximately 3.1 inches wide by 3.1 inches high by 1 inch deep). This helps in planning the mounting location.
5. Configuració i programació
After installation and power-up, the thermostat will display the current room temperature. You will need to set the time, day, and program your desired schedule.
5.1 Configuració inicial
- Configuració de l'hora i el dia: Use the specific buttons (refer to the detailed manual for exact button labels) to adjust the current time and day of the week.
- Unitat de temperatura: The display can be switched between Fahrenheit (°F) and Celsius (°C). Consult the full manual for the procedure to change this setting.
5.2 Programming the 5+2 Day Schedule
The T1050 allows for separate programming for weekdays (5 days) and weekends (2 days), with up to 4 time periods per day (e.g., Wake, Leave, Return, Sleep). Each period can have its own heating and cooling setpoints.
- Enter programming mode (refer to the full manual for button sequence).
- Select the day(s) to program (e.g., Monday-Friday).
- For each time period (e.g., Wake):
- Estableix l'hora d'inici.
- Set the desired heating temperature.
- Set the desired cooling temperature.
- Repeat for all 4 time periods for the selected days.
- Repeat the process for Saturday and Sunday.
- Sortiu del mode de programació per desar la configuració.
All programming and setpoints are stored in non-volatile memory, meaning they will not be lost during a power failure.
5.3 Thermostat Locking
The thermostat features a locking function to prevent unauthorized adjustments to setpoints. When activated, only individuals with the correct access can modify temperature settings. Refer to the detailed manual for instructions on enabling and disabling this feature.
6. Funcionament
Operating the Venstar T1050 is straightforward with its large display and soft buttons.
6.1 Selecció del mode del sistema
Premeu el botó MODE botó per anar ciclant pels modes de sistema disponibles:
- CALOR: The thermostat will only control the heating system.
- GUAI: The thermostat will only control the cooling system.
- AUTOMÀTIC: The thermostat will automatically switch between heating and cooling to maintain the desired temperature range (auto changeover).
- DESACTIVAT: Tant els sistemes de calefacció com els de refrigeració estan apagats.
The Red/Green LED indicator will illuminate red when the system is actively heating and green when actively cooling.
6.2 Funcionament del ventilador
Premeu el botó FAN botó per alternar entre els modes de ventilador:
- AUTOMÀTIC: El ventilador només funciona quan el sistema de calefacció o refrigeració està actiu.
- ACTIVITAT: El ventilador funciona contínuament, independentment de si el sistema de calefacció o de refrigeració està actiu.
6.3 Adjusting Temperature Setpoints
Utilitza el UP (▲) i ABAIX (▼) arrow buttons to adjust the desired heating or cooling temperature setpoint. In AUTO mode, both heating and cooling setpoints will be displayed and can be adjusted.
Temporary adjustments will hold until the next programmed time period begins. To permanently override the schedule, you may need to enter a hold mode (refer to the full manual).
7. Manteniment
7.1 Neteja del termòstat
Per netejar el termòstat, netegeu suaument l'exterior amb un drap suau i sec.amp cloth. Do not use abrasive cleaners, solvents, or chemical sprays, as these can damage the plastic or electronic components.
7.2 Air Filter Reminder
While the T1050 does not have a built-in filter change reminder, it is recommended to regularly check and replace your HVAC system's air filter according to the manufacturer's guidelines. A clean filter ensures optimal system performance and air quality.
8. Solució De Problemes
If you experience issues with your Venstar T1050 thermostat, please review the following common problems and solutions before contacting support.
| Problema | Causa possible | Solució |
|---|---|---|
| La pantalla del termòstat està en blanc. | No hi ha corrent al termostat. | Check the circuit breaker for your HVAC system. Ensure it is ON. Verify wiring connections. |
| El sistema de calefacció/refrigeració no respon. | Incorrect mode selected; Power issue; Compressor time guard active. | Ensure thermostat is in HEAT or COOL mode (or AUTO). Check circuit breaker. Wait 5 minutes for compressor time guard to reset. Verify wiring. |
| Temperature not reaching setpoint. | System undersized; Doors/windows open; Air filter dirty. | Ensure all windows and doors are closed. Check and replace air filter. If problem persists, consult an HVAC professional. |
| Thermostat not following schedule. | Hold function active; Incorrect programming. | Check if a temporary hold or permanent hold is active and cancel it. Review your programming settings for accuracy. |
| Thermostat locked, cannot change settings. | Thermostat locking feature is enabled. | Refer to Section 5.3 or the detailed manual for instructions on disabling the thermostat locking feature. |
For issues not listed here or if troubleshooting steps do not resolve the problem, please contact a qualified HVAC technician or Venstar customer support.
9. Especificacions
| Especificació | Detall |
|---|---|
| Marca | Venstar (Product is listed under "Generic" brand on Amazon, but is a Venstar model) |
| Nom del model | Venstar T-1050 |
| Dimensions del producte | 1" de profunditat x 3.1" d'amplada x 3.1" d'alçada (2.54 cm de profunditat x 7.87 cm d'amplada x 7.87 cm d'alçada) |
| Tipus de controlador | Pulsador |
| Característiques especials | Auto Changeover, Fan Control, Filter Indicator (implied by general thermostat features, though not explicitly stated for T1050), Low Voltage, programable |
| Color | Blanc |
| Usos específics | Aire condicionat, Forn, Bomba de calor |
| Tipus de control de temperatura | Calefacció i refrigeració |
| Tecnologia de connectivitat | Ona Z |
| Components inclosos | Anchor Screws, Manuals |
| Font d'alimentació | Elèctric amb cable |
| Voltage | 24 volts de corrent altern |
| Material | Plàstic |
| Tipus de visualització | LCD (Electro-luminous) |
| Pes de l'article | 6.4 unces (181.4 grams) |
| Compliment | Meets California Residential Title 24 |
Note on Z-Wave Connectivity: While listed in specifications, the primary product description does not highlight Z-Wave functionality. Please refer to the official Venstar T1050 documentation for confirmation of smart home integration features.
10. Garantia i Suport
Specific warranty details for the Venstar T1050 thermostat are typically provided with the product packaging or on the manufacturer's official weblloc web. Si us plau, conserveu el comprovant de compra per a reclamacions de garantia.
For technical support, troubleshooting assistance beyond this manual, or warranty inquiries, please contact Venstar customer service directly. Contact information can usually be found on the product packaging or on the official Venstar weblloc (www.venstar.com).
It is recommended to register your product with Venstar, if applicable, to receive important updates and support.