ACiQ B0D522DYZ7

Manual d'usuari del sistema de bomba de calor central inversora ACiQ 3 Tons 14.4 SEER2

Model: B0D522DYZ7

1. Introducció

This manual provides comprehensive instructions for the installation, operation, and maintenance of your ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System. Please read this manual thoroughly before installation and operation to ensure proper function and safety.

The ACiQ Inverter Heat Pump System is designed for high efficiency heating and cooling, adapting its output to meet changing weather conditions. It includes an inverter heat pump, a multi-positional cased evaporator coil, and a complete installation kit.

2. Informació de seguretat

Always adhere to local and national electrical and building codes. Installation and servicing should only be performed by qualified personnel.

  • Seguretat elèctrica: Disconnect all power before servicing. Ensure proper grounding.
  • Manipulació de refrigerants: Only certified technicians should handle refrigerants.
  • Equips de protecció individual (EPI): Wear appropriate PPE, including gloves and eye protection, during installation and maintenance.
  • Pes: Components can be heavy. Use proper lifting techniques or seek assistance.

3. Components del sistema

The ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Inverter Heat Pump: Converts AC power to DC, adjusting compressor speed and BTU output.
  • Bobina de l'evaporador: Cased multi-positional coil with factory-integrated TXV kit.
  • Kit d'instal·lació: Includes Cielo Smart Thermostat, 50' insulated line set, 1/2" x 6' 10-gauge electrical whip, 60A non-fused disconnect switch, ICM Controls Surge Protector, CPS Charging Adapter, Wall Sleeve, and Wall Mount Bracket.
ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System components

Figura 3.1: Mésview of the ACiQ Heat Pump System components, including the outdoor unit, indoor coil, thermostat, and various installation accessories.

ACiQ Complete Installation Kit

Figura 3.2: Detallada view of the complete installation kit, showing the line set, electrical whip, disconnect switch, surge protector, and smart thermostat.

4. Especificacions

4.1. Heat Pump Condenser Specifications

  • Summer Cooling Control: 36,000 BTU/H cooling precision
  • Winter Warmth Control: 36,000 to 35,000 BTU/H heating power
  • Eficiència energètica: Up to 14.4 SEER (9.30 EER2) performance
  • Summer Proof Cooling: 5°F to 122°F outdoor temp operation
  • Winter Proof Heating: 5°F to 75°F outdoor temp operation
  • Serpentina del condensador: Gold fin for durability
  • Funcionament: Quietest operation at maximum workloads
Heat Pump Condenser Specifications

Figure 4.1: Visual representation of the heat pump condenser and its key specifications.

4.2. Evaporator Coil Specifications

  • Flux d'aire: 1058.82 CFM
  • Pressió: 0.28 In. wg.
  • Deshumidificació: 4.64
  • Mides (L x P x A): 21.52 x 20.98 x 23.58 polzades (547 x 533 x 599 mm)
  • Packing (W x D x H): 23.47 x 26.18 x 25.39 polzades (596 x 665 x 645 mm)
  • Pes net/brut: 62.19 / 71.00 lbs (28.20 / 32.20 kg)

Note: The coil is specifically designed for use with gas furnaces or modular blowers and cannot be substituted for a one-piece air handler.

Evaporator Coil Specifications

Figura 4.2: Detallada view of the evaporator coil with its dimensions and performance metrics.

4.3. Dimensions generals

System Measurements

Figure 4.3: Overall dimensions of the outdoor heat pump unit and the evaporator coil.

5. Configuració i instal·lació

Installation of this system requires specialized knowledge and tools. It is strongly recommended that installation be performed by a certified HVAC technician.

5.1. Llista de verificació prèvia a la instal·lació

  • Comproveu que tots els components estiguin presents i sense danys.
  • Ensure proper electrical supply is available (voltage, ampera).
  • Confirm adequate space for both indoor and outdoor units, allowing for proper airflow and service access.
  • Review local building codes and obtain necessary permits.

5.2. Outdoor Unit Placement

Place the outdoor unit on a level, stable surface, away from obstructions that could impede airflow. Ensure sufficient clearance around the unit for maintenance and proper operation.

Outdoor Unit Placement Example

Figura 5.1: Example of an outdoor unit installed on a wall mount bracket, demonstrating proper clearance.

5.3. Evaporator Coil Installation

The evaporator coil is multi-positional. Install it in conjunction with a gas furnace or modular blower. Ensure proper drainage for condensate.

5.4. Line Set and Electrical Connections

  • Connect the insulated line set between the outdoor unit and the evaporator coil. Ensure proper flaring and torque.
  • Install the electrical whip and disconnect switch according to electrical codes.
  • Connect the ICM Controls Surge Protector for electrical protection.

5.5. Instal·lació del termòstat

Install the Cielo Smart Thermostat according to its dedicated instructions. This thermostat allows for app control and integration with smart home systems like Alexa, Google Home, Siri, SmartThings, and IFTTT.

Cielo Smart Thermostat Features

Figure 5.2: Diagram illustrating the features and connectivity options of the Cielo Smart Thermostat.

6. Instruccions de funcionament

Once installed, the system can be operated via the Cielo Smart Thermostat or its associated mobile application.

6.1. Funcionament bàsic

  • Encès: Ensure the disconnect switch is in the ON position.
  • Selecció del mode: Use the thermostat to select operating modes: Cooling, Heating, Fan Only, or Auto.
  • Configuració de la temperatura: Ajusteu la temperatura desitjada mitjançant els controls del termòstat.

6.2. Smart Thermostat Features

The Cielo Smart Thermostat offers advanced features for enhanced comfort and energy savings:

  • Programació: Program daily or weekly schedules to optimize energy use.
  • Accés remot: Control your system from anywhere using the mobile app.
  • Control de veu: Integrate with Amazon Alexa, Google Assistant, or Apple Siri for hands-free control.
  • Integració de la llar intel·ligent: Connect with SmartThings and IFTTT for advanced automation.

7. Manteniment

Regular maintenance is crucial for optimal performance and longevity of your ACiQ system. It is recommended to have a qualified technician perform annual inspections.

7.1. Manteniment d'usuaris

  • Substitució del filtre d'aire: Check and replace air filters monthly or as needed, especially during peak usage seasons.
  • Neteja de la unitat exterior: Keep the area around the outdoor unit clear of debris, leaves, and obstructions. Gently clean the exterior coils with a soft brush and water if necessary.
  • Desguàs de condensats: Periodically check the condensate drain line for clogs and ensure proper drainage.

7.2. Manteniment professional

An annual professional tune-up typically includes:

  • Refrigerant level check and adjustment.
  • Coil cleaning (indoor and outdoor).
  • Electrical connection inspection and tightening.
  • Blower motor and fan inspection.
  • Calibratge del termòstat.

8. Solució De Problemes

This section provides solutions to common issues. For problems not listed here, or if solutions do not resolve the issue, contact a qualified HVAC technician.

ProblemaCausa possibleSolució
El sistema no s'encénSense electricitat, interruptor automàtic saltat, problema amb el termòstatCheck disconnect switch, reset breaker, ensure thermostat is powered and set correctly.
Calefacció/refrigeració insuficientsDirty air filter, blocked outdoor unit, low refrigerant, incorrect thermostat settingReplace air filter, clear obstructions from outdoor unit, check thermostat settings. Contact technician for refrigerant issues.
Sorolls inusualsPeces soltes, obstrucció del ventilador, problema del compressorInspect for loose panels or debris. If noise persists, contact a technician.
Fuites d'aigua de la unitat interiorClogged condensate drain line, frozen evaporator coilClear drain line. If coil is frozen, turn off system and allow to thaw, then check airflow. Contact technician if issue persists.

9. Informació de la garantia

The ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System comes with a comprehensive warranty:

  • Parts: 7-year warranty on parts.
  • Compressor: 12 anys de garantia del compressor.

Condicions de garantia: The warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer at no additional charge. Please retain your proof of purchase and installation records.

10. Suport i contacte

For technical support, warranty claims, or service inquiries, please contact ACiQ customer service or visit our official weblloc.

ACiQ Official Weblloc: Visita la botiga ACiQ a Amazon

Please have your model number (B0D522DYZ7) and purchase date ready when contacting support.

Documents relacionats - B0D522DYZ7

Preview Manual d'instal·lació dels sistemes d'inversor central ACiQ
Manual d'instal·lació complet per als sistemes d'aire condicionat i bomba de calor amb inversor central ACiQ, que detalla les precaucions de seguretat, les canonades de refrigerant, la instal·lació de la unitat exterior, el cablejat, les especificacions d'alimentació, l'evacuació de l'aire i els procediments de prova de funcionament.
Preview Guia d'inici ràpid del sistema de bomba de calor d'alta eficiència ACiQ: Sèries estàndard i extreme amb R-454B
Guia d'inici ràpid per a la instal·lació i connexió de sistemes de bomba de calor d'alta eficiència ACiQ (sèrie estàndard i extrema amb R-454B). Cobreix el cablejat del termòstat, la configuració dels interruptors DIP i la configuració bàsica per a diversos escenaris d'instal·lació.
Preview Manual d'instal·lació de la unitat exterior dels sistemes d'inversor central ACiQ
Manual d'instal·lació complet per a les unitats exteriors dels sistemes d'inversor central ACiQ, que cobreix les precaucions de seguretat, les canonades de refrigerant, el cablejat, la instal·lació de la unitat i els procediments de prova per a models com ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB i altres.
Preview Sistema de bomba de calor amb conductes ACiQ de nova generació: guia d'inici ràpid per al cablejat del termòstat
Aquesta guia proporciona informació essencial per connectar i cablejar termostats al sistema de bomba de calor per conductes ACiQ Next Gen. Detalla les opcions de connexió recomanades i alternatives, inclosa la configuració dels interruptors DIP i les configuracions del bloc de terminals per a diversos tipus de termostats.
Preview Manual del propietari i guia d'operació del sistema split de bomba de calor central ACiQ
Manual complet del propietari per als sistemes split de bomba de calor central ACiQ, que cobreix les precaucions de seguretat, les condicions de funcionament, les característiques, els consells per estalviar energia, la cura i el manteniment, i la resolució de problemes per als models ACiQ-24, ACiQ-36 i ACiQ-48.
Preview Manual d'instal·lació de la unitat exterior dels sistemes d'inversor central ACiQ
Manual d'instal·lació complet per a les unitats exteriors dels sistemes d'inversor central ACiQ, que cobreix les precaucions de seguretat, les canonades de refrigerant, la instal·lació de la unitat exterior, el cablejat, les especificacions d'alimentació, l'evacuació de l'aire i els procediments de prova de funcionament. Inclou detalls del model i notes importants per a una configuració correcta.