Senville 13KW

Manual d'usuari de l'escalfador d'aigua elèctric sense dipòsit Senville de 13 kW i 240 V

Model: 13KW

1. Producte acabatview

The Senville 13KW Electric Tankless Water Heater provides on-demand hot water for residential and light commercial applications. Its compact design eliminates the need for bulky storage tanks, making it suitable for various spaces. This unit features self-modulating technology to maintain a consistent water temperature, ensuring comfort and efficiency.

Les característiques clau inclouen:

  • Instant and reliable hot water delivery.
  • Energy-efficient performance, heating water only when needed.
  • Space-saving, compact design for flexible installation.
  • Consistent temperature control with advanced self-modulating technology.
  • Durable construction with a 5-year manufacturer replacement warranty.
Senville 13KW Tankless Water Heater front view amb pantalla digital

Imatge 1.1: Frontal view of the Senville 13KW Electric Tankless Water Heater, showcasinpel seu disseny elegant i el seu panell de control digital.

Senville Tankless Water Heater providing endless hot water flow

Image 1.2: The tankless water heater ensures a continuous supply of hot water, ideal for busy households.

2. Informació de seguretat

Si us plau, llegiu i comprengui totes les instruccions de seguretat abans d'instal·lar, fer funcionar o realitzar el manteniment d'aquest aparell. Si no segueix aquestes instruccions, es podrien produir danys materials, lesions greus o la mort.

  • Seguretat elèctrica: This unit requires a dedicated electrical circuit. Ensure all wiring complies with local and national electrical codes. Professional installation by a qualified electrician is highly recommended. Do not attempt to install or repair electrical components if you are not qualified.
  • Pressió de l'aigua: Ensure water pressure is within the specified range (30-150 psi). Excessive pressure can damage the unit.
  • Configuració de temperatura: Be cautious when setting high temperatures to avoid scalding. Consider installing anti-scald devices at fixtures.
  • Protecció contra fuites: The unit features sensitive leakage protection. Regularly inspect for any signs of leaks.
  • Protecció contra el sobreescalfament: La unitat està equipada amb protecció contra sobreescalfament. Noamper amb característiques de seguretat.
  • Water and Electricity Separation: The design ensures water and electricity are safely separated.

3. Guia d'instal·lació

Professional installation is strongly recommended for this electric tankless water heater to ensure proper function and compliance with all electrical and plumbing codes.

3.1 Selecció del lloc

Choose a location that is easily accessible for maintenance, protected from freezing temperatures, and close to the main electrical panel to minimize wiring costs. The unit is designed for indoor use only.

Diagram showing compact and easy installation of the Senville tankless water heater in various locations like bathroom, laundry, and kitchen

Image 3.1: The compact design allows for flexible installation in bathrooms, laundry rooms, or kitchens, saving valuable space.

3.2 Requisits elèctrics

The Senville 13KW model requires a 240V electrical supply. Refer to the specifications table for detailed electrical parameters.

  • Voltage: 240 Volts
  • Wattage: 13000 watts
  • Màx. Amp Càrrega: 1 x 54.1 A
  • Recommended Minimal Wire Size: 1 x 6 AWG copper wire
  • Interruptor recomanat: 1 x 60 A double-pole breaker

Ensure your electrical panel has sufficient capacity and that the wiring run is appropriate for the distance to avoid voltage drop. Consult a qualified electrician for proper sizing and installation.

3.3 Requisits de fontaneria

  • Connexió d'aigua: 1/2" NPT
  • Min. Permissible Pressure: 30 psi / 2.07 bar / 0.207 MPa
  • Màx. Pressió permesa: 150 psi / 10.34 bar / 1.034 MPa
  • Min. Water Flow to Activate Unit: 0.3 GPM (1.2 L / min)

It is recommended to install a tankless water heater bypass valve/isolator kit for easier future maintenance and descaling.

3.4 Flow Rate and Capacity Guide

The performance of your tankless water heater depends on the incoming water temperature and desired flow rate. Use the guide below to determine the appropriate flow for your area and needs.

Tankless Water Heater Selection Guide showing US map with inlet water temperatures and corresponding GPM at 108°F for different kW models and fixture types

Image 3.2: This selection guide helps determine the appropriate flow rate based on your geographical location's inlet water temperature and the desired outlet temperature.

Per utilitzar la guia:

  1. Find your location on the map to determine the average inlet water temperature.
  2. Check the advised flow rate (GPM) at your desired outlet water temperature (e.g., 108°F).
  3. Calculate the fixtures that may run simultaneously to ensure your unit can meet the demand. For the 13KW model, typical flow rates for fixtures are: Bathroom Faucet (0.5 GPM), Kitchen Sink (1-1.5 GPM), Shower Head (1.5-2 GPM), Laundry (1-1.5 GPM), Dishwasher (1-2 GPM).

4. Instruccions de funcionament

The Senville 13KW Tankless Water Heater features a user-friendly digital display for temperature control.

4.1 Engegada/apagada

Premeu el botó d'engegada (U) on the control panel to turn the unit on or off. The digital display will illuminate when the unit is active.

4.2 Configuració de la temperatura de l'aigua

Use the '+' and '-' buttons on the control panel to adjust the desired water temperature. The display will show the set temperature. The unit's self-modulating technology will automatically adjust power levels to maintain this temperature as water flows through.

4.3 Flow Rate Indication

The digital display may also show the current flow rate (L/min or GPM) when hot water is being drawn, providing real-time operational feedback.

5. Manteniment

Regular maintenance ensures optimal performance and extends the lifespan of your tankless water heater.

5.1 Descaling and Flushing

Over time, mineral deposits (scale) can build up inside the water heater, reducing efficiency. It is recommended to descale and flush the unit annually, or more frequently in areas with hard water.

  • Bypass Kit: If not already installed, consider purchasing and installing a tankless water heater bypass valve/isolator kit. This kit simplifies the flushing process by allowing you to isolate the unit and circulate a descaling solution without affecting your home's plumbing.
  • Flushing Procedure: A flushing kit, typically consisting of a pump and a bucket, is used to circulate an acid solution (e.g., white vinegar or a commercial descaling agent) through the water heater. Follow the instructions provided with your flushing kit and descaling solution.

5.2 Inspecció general

Periodically inspect the unit for any visible leaks, corrosion, or damage to the electrical connections. Address any issues promptly.

6. Solució De Problemes

Aquesta secció ofereix solucions a problemes comuns que podeu trobar.

6.1 Sense aigua calenta

  • Comproveu la potència: Ensure the unit is powered on and the circuit breaker has not tripped.
  • Flux d'aigua: Verify that the minimum water flow rate (0.3 GPM) is met. If flow is too low, the unit may not activate.
  • Temperatura d'entrada: In very cold climates, if the inlet water temperature is extremely low, the unit may struggle to reach the desired temperature at high flow rates. Reduce flow or adjust temperature setting.
  • Scale Buildup: Significant scale buildup can restrict water flow and heating efficiency. Perform descaling maintenance.
  • Codis d'error: Check the digital display for any error codes and consult the full product manual (if available) for their meaning.

6.2 Temperatura inconsistent de l'aigua

  • Fluctuating Flow: Ensure consistent water flow from the fixture. Rapid changes in flow can affect temperature.
  • Múltiples fixacions: If multiple hot water fixtures are running simultaneously, the unit may be exceeding its capacity. Reduce the number of active fixtures.
  • Scale Buildup: As with no hot water, scale can cause inconsistent heating.

6.3 Fuites

  • Comproveu les connexions: Inspect all water inlet and outlet connections for tightness.
  • Internal Leak: If leaks persist or appear to be internal, immediately turn off the water supply and electrical power to the unit and contact a qualified technician.

For issues not covered here, or if troubleshooting steps do not resolve the problem, contact Senville customer support or a qualified professional.

7. Especificacions

Detailed technical specifications for the Senville 13KW Electric Tankless Water Heater.

ParàmetreValor
Model de producte13KW
Subministrament elèctric240 VAC / 60 Hz / Single Phase
Potència nominal d'entrada13 kW
Màx. Amp Carrega1 x 54.1 A
Recommended Minimal Wire Size1 x 6 AWG
Interruptor recomanat1 x 60 A
Connexió d'aigua1/2" NPT
Min. Permissible Pressure30 psi / 2.07 bar / 0.207 MPa
Pressió màxima admissible150 psi / 10.34 bar / 1.034 MPa
Min. Water Flow to Activate Unit0.3 GPM (1.2 L / min)
Amplada8 3/8" (213 mm)
profunditat3 7/8" (97 mm)
Alçada16 7/8" (430 mm)
Pes de l'article10.14 lliures
ASINB0D8TN2LWN
UPC893088008873

8. Garantia i Suport

The Senville 13KW Electric Tankless Water Heater is backed by a 5-year manufacturer replacement warranty, garantint la tranquil·litat pel que fa al seu rendiment i durabilitat.

For warranty claims, technical support, or any inquiries, please contact Senville customer service. You can find contact information on the official Senville weblloc web o a través de la documentació de compra.

Per obtenir recursos addicionals i informació sobre el producte, visiteu Senville Store on Amazon.

Documents relacionats - 13KW

Preview Calefactor de torre de ceràmica Senville SENCH-22 amb ventilador: manual d'usuari i guia de seguretat
Manual d'usuari complet per a l'escalfador de torre de ceràmica Senville SENCH-22 amb ventilador. Inclou instruccions de seguretat, procediments d'ús, característiques, manteniment i consells per a la resolució de problemes.
Preview Manuel d'Installation Climatiseur Mural Senville
Guia d'instal·lació completa per a climatitzadors muraux Senville, couvrant la seguretat, les dimensions, la tuyauterie, el câblage i els procediments de prova.
Preview Senville Electric Residential Hybrid Water Heater Use & Care Manual
Comprehensive use and care manual for Senville Electric Residential Hybrid Water Heaters, including installation instructions, operating guidelines, safety precautions, and troubleshooting tips.
Preview Manual del propietari del comandament a distància Senville
Manual d'usuari complet per als comandaments a distància Senville, que detalla les especificacions, les funcions, les operacions bàsiques i avançades i la resolució de problemes de les unitats d'aire condicionat. Cobreix els models RG10R(M2S)/BGEFU1, RG10R(E2S)/BGEFU1 i RG10R(F2S)/BGEFU1.
Preview Manual d'instal·lació d'aire condicionat tipus split
Guia d'instal·lació completa per a aire condicionat tipus split, que cobreix les precaucions de seguretat, la instal·lació de la unitat interior i exterior, les canonades de refrigerant, les connexions elèctriques, l'evacuació de l'aire, les comprovacions de fuites de gas, les proves de funcionament i els procediments d'embalatge/desembalatge.
Preview Instruccions de muntatge del suport de muntatge mini-split Senville SL550
Instruccions detallades de muntatge per al suport de paret mini-split Senville SL550, dissenyat per a aires condicionats sense conductes i bombes de calor. Inclou les eines necessàries, una llista de maquinari i una guia d'instal·lació pas a pas.