1. Introducció
The Walfront Ethernet Relay Switch Controller is an advanced 8-way relay module board designed for versatile control applications. It features 8-way 10A relay outputs with normally open and normally closed contacts, and 8-way switch on-off inputs. This controller supports various network modes including TCP server, TCP client, and UDP, making it suitable for smart home automation, industrial control, and remote monitoring of electrical equipment. Its robust design and flexible firmware options provide a reliable solution for integrating physical devices into network-based control systems.

Figura 1: superior view of the Walfront Ethernet Relay Switch Controller, showing the relay outputs, input terminals, Ethernet port, and power input.
2. Característiques clau
- 8-Way 10A Relay Outputs: Provides normally open (NO) and normally closed (NC) contacts for flexible control.
- 8-Way Switch On-Off Inputs: Allows for external trigger inputs, compatible with sensors or button switches.
- Multiple Network Modes: Supports TCP server, TCP client, and UDP modes for diverse network integration.
- Multi-Client Support: In TCP server mode, it can support up to 4 client connections simultaneously.
- Automatic Network Reconnection: Ensures continuous operation by automatically reconnecting if the network goes offline.
- 32-bit MCU: Utilizes a powerful microcontroller for efficient processing.
- User-Defined Naming: Allows for custom device names, simplifying management in multi-device setups.
- Configurable Packet Time: Supports user-defined packet time and off-line restore functionality.
- Opcions de firmware: General firmware (slave mode, command control), Switch On-Off Unvarnished Transmission firmware (paired control), and Access Control firmware (supports four 26 protocol read heads).
- C++ Source Code Provided: Facilitates secondary development and customization.
- Aplicacions: Ideal for smart home control, remote control of lights, motors, and other electrical equipment, and computer room power failure detection.
3. Guia de configuració
3.1. Connexió d'alimentació
Connect a 9-24V DC power supply to the power input terminal (labeled '9-24V') on the board. Ensure correct polarity (+ and -) to prevent damage to the device.
3.2. Connexió a la xarxa
Connect a standard Ethernet cable from your network router or switch to the RJ45 Ethernet port on the controller. The device supports automatic network reconnection.
3.3. Device Connections
Sortides de relé: Connect your electrical equipment (lights, motors, etc.) to the 8 relay output terminals. Each relay has Normally Open (NO), Common (COM), and Normally Closed (NC) contacts. Refer to the labels on the board for correct wiring.
Entrades de commutació: Connect external sensors (e.g., human body infrared sensors, smoke alarms) or button switches to the 8 switch input terminals (labeled IN1 to IN8, with corresponding COM and +5V terminals). These inputs can trigger actions or provide status feedback.

Figura 2: Detallada view of the controller's terminal blocks for power, Ethernet, inputs, and relay outputs.
3.4. Configuració del programari
Use the provided network parameter setting software to configure the device's network settings (e.g., IP address, subnet mask, gateway) and operating mode (TCP server, TCP client, or UDP). This software also allows for user-defined naming of the device.
4. Instruccions de funcionament
4.1. Modes de funcionament
- Mode de servidor TCP: The controller acts as a server, listening for incoming connections from up to 4 clients. Commands are sent from clients to control the relays.
- Mode client TCP: The controller connects to a specified TCP server. Commands can be sent from the server to the controller.
- Mode UDP: The controller communicates using UDP packets, suitable for broadcast or multicast applications.
4.2. Firmware Types and Usage
The device supports downloading three different firmware types through the configuration project:
- General Firmware: This is the default firmware, operating in slave mode. Relays are controlled by sending specific commands over the network. This is suitable for most general-purpose control applications.
- Switch On-Off Unvarnished Transmission Firmware: This firmware is designed to be used in pairs. One controller's input directly controls the output of another paired controller. Each input on the transmitting unit corresponds to a specific relay output on the receiving unit, enabling direct, unvarnished signal transmission.
- Access Control Firmware: This specialized firmware allows the controller to connect to and manage up to four 26 protocol read heads, making it suitable for access control systems.

Figura 3: Despeses generals view of the controller, highlighting the main components and layout.
4.3. Desenvolupament secundari
C++ source code is provided to assist users with secondary development, allowing for custom applications and integration into existing systems. This enables advanced users to tailor the controller's functionality to specific project requirements.
5. Manteniment
The Walfront Ethernet Relay Switch Controller is designed for reliable operation with minimal maintenance. Follow these guidelines to ensure longevity:
- Mantenir net: Regularly clean the device with a soft, dry cloth. Avoid using liquid cleaners or solvents.
- Condicions ambientals: Operate the device within its specified temperature and humidity ranges. Avoid extreme temperatures, direct sunlight, and high moisture environments.
- Font d'alimentació: Ensure a stable and correct voltage power supply (9-24V DC) is used. Unstable power can lead to malfunction.
- Connexions: Reviseu periòdicament totes les connexions del cablejat per assegurar-vos que estiguin ben fixades i que no presentin corrosió.
- Actualitzacions de firmware: Comproveu el del fabricant weblloc web per a qualsevol actualització de firmware disponible que pugui millorar el rendiment o afegir noves funcions.
6. Solució De Problemes
- El dispositiu no s'encén:
- Verify the power supply is connected correctly and providing the specified 9-24V DC.
- Comproveu si l'adaptador de corrent i el cable estan danyats.
- Sense connectivitat de xarxa:
- Ensure the Ethernet cable is securely connected to both the controller and the network router/switch.
- Check the network status lights on the Ethernet port.
- Verify network settings (IP address, subnet mask, gateway) using the configuration software. Ensure there are no IP conflicts on your network.
- Reinicieu el vostre encaminador/commutador de xarxa.
- Relays Not Responding:
- Confirm the device has network connectivity.
- Ensure the correct commands are being sent to the controller based on the installed firmware (General, Unvarnished, or Access Control).
- Check the wiring of the electrical equipment connected to the relay outputs.
- Verify the power rating of the connected load does not exceed 10A per relay.
- Input Signals Not Detected:
- Check the wiring of the sensors or switches connected to the input terminals.
- Ensure the input device is functioning correctly.
- Problemes d'actualització del firmware:
- Ensure a stable network connection during the firmware update process.
- Follow the instructions provided with the firmware update tool precisely.
7. Especificacions
| Característica | Especificació |
|---|---|
| Número de model | WALFRONTwue56z14oh |
| Marca | Walfront |
| Canals de retransmissió | 8 vies |
| Classificació del corrent del relé | 10A per canal |
| Els canals d'entrada | 8-way switch on-off input |
| Font d'alimentació | 9-24V DC |
| Protocols de xarxa | Servidor TCP, Client TCP, UDP |
| MCU | Microcontrolador de 32 bits |
| Tipus de connector | Terminals de cargol |
| Tipus de muntatge | DIN Rail Mount (implied by design) |
| Mode d'operació | Automàtic |
| Dimensions (aprox.) | 16 x 15 x 5 cm |
| Pes (aprox.) | 232 g |
| País d'origen | Xina |
8. Garantia i Suport
For warranty information and technical support, please refer to the official Walfront weblloc web o poseu-vos en contacte amb el vostre punt de compra. Conserveu el rebut de compra com a comprovant de compra per a qualsevol reclamació de garantia.
For further assistance or to download the latest software and firmware, please visit the Botiga Walfront a Amazon or the manufacturer's official support channels.