Maxspect MJ-GF316

Maxspect Jump Gyre DC 4000 gph Aquarium Wave Maker Pump MJ-GF316

Manual d'usuari

Introducció

This manual provides detailed instructions for the installation, operation, and maintenance of your Maxspect Jump Gyre DC 4000 gph Aquarium Wave Maker Pump, model MJ-GF316. This device is designed to create powerful, uniform water flow within your aquarium, eliminating dead spots and promoting a healthy aquatic environment. Please read this manual thoroughly before use to ensure proper function and longevity of the product.

Instruccions importants de seguretat

Contingut del paquet

Verifiqueu que tots els components siguin presents al paquet:

Maxspect Jump Gyre Flow Pump MJ-GF316 and Controller

Image: Maxspect Jump Gyre Flow Pump MJ-GF316 and its dedicated controller.

Accessories for Maxspect Jump Gyre Flow Pump, including flow guards, screws, and mounting strips

Image: Various accessories included with the pump, such as flow guards, screws, and mounting strips.

Configuració

1. Muntatge de la bomba

The Maxspect Jump Gyre pump utilizes a magnetic mounting system for secure placement. It can be mounted vertically or horizontally on the aquarium glass.

  1. Identify the inner and outer magnetic mounts. The pump attaches to the inner mount.
  2. Place the pump (with the inner magnetic mount attached) inside the aquarium at your desired location.
  3. Align the outer magnetic mount on the exterior of the aquarium glass, directly opposite the inner mount. The magnets will secure the pump in place.
  4. Ensure the pump is positioned to create optimal water flow without disturbing substrate or corals excessively.
Maxspect Jump Gyre Flow Pump mounted horizontally inside an aquarium

Image: The Maxspect Jump Gyre Flow Pump mounted horizontally on the inside of an aquarium glass.

2. Connecting the Controller and Power Supply

Connect the pump to the controller and then the controller to the power supply.

  1. Connect the pump's cable to the designated port on the controller. Ensure a secure connection.
  2. Connect the power supply adapter to the controller's power input port.
  3. Connecteu la font d'alimentació a una presa de corrent adequada.
  4. The controller's LED display should illuminate, indicating power.
Maxspect Jump Gyre Flow Pump Controller with LED display and connection ports

Image: The Maxspect Jump Gyre Flow Pump controller, showing its LED display and connection points for the pump and power supply.

Power adapter for Maxspect Jump Gyre Flow Pump

Image: The power adapter used to supply electricity to the Maxspect Jump Gyre Flow Pump system.

Instruccions de funcionament

Controlador acabatview

The controller features an LED display and several buttons for adjusting pump settings.

Modes de funcionament

The Maxspect Jump Gyre offers 5 distinct flow patterns to simulate natural aquatic environments:

  1. Mode aleatori: Generates unpredictable flow patterns, mimicking natural ocean currents.
  2. Rapid Pulse Mode: Creates short, intense bursts of flow, ideal for dislodging detritus.
  3. Slow Pulse Mode: Produces gentle, rhythmic pulses for broad water movement.
  4. Gradual Pulse Mode: Features a smooth transition between high and low flow, simulating tidal changes.
  5. Mode constant: Maintains a steady, continuous flow at a set intensity.

To select a mode, press the Mode button until the desired mode is displayed. Use the adjust dial/buttons to set the flow intensity for the chosen mode.

Manteniment

Regular cleaning is essential to maintain optimal performance and extend the lifespan of your pump.

Neteja de la bomba

  1. Desconnecteu l'alimentació: Always unplug the power supply from the wall outlet before handling the pump.
  2. Remove from Aquarium: Carefully detach the pump from the magnetic mount and remove it from the aquarium.
  3. Desmuntar: Gently twist and pull apart the pump components, including the impellers and protective cages. Refer to the diagram for proper disassembly.
  4. Components nets: Rinse all parts under fresh water to remove loose debris. For stubborn algae or calcium deposits, soak the components in a diluted vinegar solution or a commercially available aquarium pump cleaner for several hours. Use a soft brush to scrub away any remaining residue.
  5. Esbandida bé: After cleaning, rinse all components thoroughly with fresh water to remove any cleaning solution residue.
  6. Torneu a muntar: Carefully reassemble the pump, ensuring all parts are correctly aligned and securely fitted.
  7. Torneu a instal·lar: Place the cleaned pump back into the aquarium and reconnect the power.
Maxspect Jump Gyre Flow Pump, disassembled for cleaning

Image: The Maxspect Jump Gyre Flow Pump, showing its main body and impeller sections, ready for disassembly and cleaning.

Resolució de problemes

If you encounter issues with your Maxspect Jump Gyre pump, refer to the table below for common problems and solutions.

ProblemaCausa possibleSolució
La bomba no s'encénNo power to controller; loose connection; faulty power supply.Check power outlet; ensure all cables are securely connected; test power supply if possible.
Flux d'aigua feble o nulImpeller obstructed; pump dirty; incorrect mode/setting.Disconnect power and clean pump thoroughly; check controller settings.
Sorolls o vibracions inusualsDebris in impeller; worn impeller; improper mounting.Disconnect power and clean impeller; ensure pump is securely mounted and not touching tank walls.
La pantalla del controlador no funcionaNo power; controller malfunction.Check power connection to controller; contact support if issue persists.

Especificacions

CaracterísticaDetall
ModelMJ-GF316
CaudalUp to 4227 gph (4000 gph nominal)
Consum d'energia45W
Dimensions (bomba)12.25 "L x 3.5" W x 1.75" H
Voltage12 volts (CC)
MaterialPlàstic
Pes de l'article3.96 lliures
Components inclososController, Power Supply, Pump

Garantia i Suport

For warranty information, please refer to the documentation provided with your purchase or visit the official Maxspect website. If you require technical support or have questions not covered in this manual, please contact Maxspect customer service through their official channels.

Documents relacionats - MJ-GF316

Preview Manual d'usuari de la bomba de flux Gyre de la sèrie 300 de Maxspect Gyre Cloud Edition
Manual d'usuari complet per a la bomba de flux Gyre Maxspect Gyre sèrie 300 Cloud Edition, que detalla la instal·lació, el funcionament, el manteniment, les precaucions de seguretat i la informació de garantia.
Preview Manual d'usuari del skimmer de proteïnes Maxspect Jump Series
Una guia completa per a l'espumador de proteïnes Maxspect Jump Series, que detalla la configuració, el funcionament, el manteniment, les precaucions de seguretat i les peces de recanvi per a entusiastes de l'aquari.
Preview Manual d'usuari del skimmer de proteïnes Maxspect Jump Series
Manual d'usuari complet per a l'espumador de proteïnes Maxspect Jump Series, que cobreix la configuració, el funcionament, el manteniment i la garantia. Les característiques inclouen entrades d'aigua dobles, rodes d'agulla dobles i un sensor de desbordament.
Preview Maxspect Gyre sèrie 300CE Cloud Edition: Guia de funcionament gairebé silenciós, seguretat i garantia
Un manual d'usuari complet per a la bomba de flux Maxspect Gyre 300CE Series Cloud Edition, que detalla el seu funcionament gairebé silenciós, la tecnologia d'ona sinusoidal, el contingut del paquet, la instal·lació, el funcionament, el manteniment, les precaucions de seguretat i la garantia limitada.
Preview Manual d'usuari del sistema d'il·luminació LED Maxspect Jump Series MJ-L165
Manual d'usuari complet per al sistema d'il·luminació LED Maxspect Jump Series MJ-L165, que cobreix la instal·lació, el funcionament, les precaucions de seguretat i el manteniment.
Preview Maxspect Dice Series Pico Cube Smart Aquarium User Manual - Setup, Operation, Maintenance
Comprehensive user manual for the Maxspect Dice Series Pico Cube Smart Aquarium. Learn about setup, safety precautions, component identification, operation instructions, maintenance procedures, and warranty details. Envision life vividly with Maxspect.