Wellue WBP02A

Wellue 24-Hour Ambulatory Blood Pressure Monitor (ABPM) User Manual

Model: WBP02A

1. Introducció

The Wellue 24-Hour Ambulatory Blood Pressure Monitor (ABPM) is designed for continuous, automatic blood pressure measurement over a 24-hour period. This device helps to provide a comprehensive overview of blood pressure fluctuations, including during sleep, and can assist in identifying conditions such as white coat hypertension or masked hypertension. It is a clinically accurate device, certified by ESH IP 2010, and recommended by the European Society of Hypertension (ESH) and the British and Irish Hypertension Society (BIHS).

Man wearing Wellue 24-Hour ABPM on arm, with icons indicating day and night monitoring.

Image 1.1: The Wellue ABPM device enables continuous blood pressure monitoring throughout the day and night.

2. Què s'inclou

Si us plau, comproveu el contingut del paquet per assegurar-vos que hi hagi tots els elements:

All components of the Wellue 24-Hour ABPM package laid out: monitor, cuffs, USB disk, charger, cable, clip, silicone cover, manual.

Imatge 2.1: acabatview of all items included in the Wellue ABPM package.

3. Configuració

3.1 Càrrega del dispositiu

Before first use, fully charge the monitor using the provided USB data cable and fast charger. Connect the USB cable to the monitor and the charger, then plug the charger into a power outlet. A full charge takes approximately 2.5 hours and supports up to 200 measurements.

3.2 Installing the Cuff

  1. Select the appropriate cuff size (22-36 cm or 33-43 cm) for your arm. The cuff should fit snugly but not too tightly.
  2. Attach the cuff to the monitor's air tube connector.
  3. Wrap the cuff around your upper arm, ensuring the artery mark on the cuff aligns with your brachial artery. The bottom edge of the cuff should be approximately 2-3 cm above the elbow joint.
  4. Secure the cuff firmly using the hook-and-loop fastener.

3.3 Instal·lació del programari

The ABPM software is provided on the included USB disk. Insert the USB disk into your PC and follow the on-screen instructions to install the software. The software is compatible with Microsoft Windows operating systems (Win2003/WinXP/Win7/Win10/Win11).

3.4 Connexió a l'ordinador

To transfer data or program the device, connect the monitor to your PC using the provided USB data cable. Ensure the software is running on your PC.

Wellue ABPM device connected to a laptop via USB cable, with the software interface visible on the screen.

Image 3.1: Connecting the ABPM device to a PC for data transfer and programming.

4. Funcionament del dispositiu

4.1 Starting a Measurement Session

Once the cuff is correctly applied and the device is charged, press the power button to turn on the monitor. The device will automatically begin measurements according to the programmed schedule. You can also initiate a manual measurement by pressing the designated button on the device.

A man pressing a button on the Wellue ABPM device worn on his arm.

Image 4.1: Initiating a measurement on the Wellue ABPM device.

4.2 Programming Measurement Intervals

The device can be programmed via the PC software to take measurements at various intervals:

4.3 Data Transfer and Analysis with PC Software

After completing a monitoring session, connect the device to your PC to transfer the stored data. The software allows for comprehensive analysis:

A person sleeping with the ABPM device on their arm, with a graphical overlay showing blood pressure trends over 24 hours.

Image 4.2: Monitoring blood pressure during sleep and visualizing data trends.

A medical professional reviewing blood pressure data and reports on a laptop using the Wellue ABPM software.

Image 4.3: Analyzing comprehensive blood pressure data with the Wellue PC software.

5. Manteniment

5.1 Cleaning the Device and Cuffs

Wipe the monitor and cuffs with a soft, dry cloth. For disinfection, use a cloth lightly dampened with a mild disinfectant. Do not immerse the device in water or use abrasive cleaners.

5.2 Cura de la bateria

The device uses a rechargeable Li-ion battery. To prolong battery life, avoid fully discharging the battery frequently. Recharge the device when the battery indicator is low. Store the device with a partial charge if not used for extended periods.

5.3 Calibració

For continued accuracy, the device requires calibration at least once every two years. Please contact Wellue customer support for calibration services.

5.4 Condicions d'emmagatzematge

Store the device in a clean, dry place away from direct sunlight and extreme temperatures. Ensure the storage area is well-ventilated and free from corrosive gases. Recommended storage temperature: -20℃ to +55℃; Relative humidity: below 95%; Atmospheric pressure: 70KPa to 106KPa.

6. Solució De Problemes

If you encounter issues with your Wellue ABPM, please refer to the following common problems and solutions:

If problems persist, please contact Wellue customer support for assistance.

7. Especificacions

CaracterísticaEspecificació
ModelWBP02A
Dimensions119 x 52 x 21 mm (4.7" x 2.1" x 0.8")
Pes105 g (3.7 oz) (including battery)
Mides de punysAdult: 22-36 cm (8”-14”); Extra Large: 33-43 cm (13”-17”)
Requisits de PCUSB port; Microsoft Win2003/WinXP/Win7/Win10/Win11
MostraPantalla LED
Condicions de treballTemperature: 5℃~40℃; RH: 10%~95%; Atmospheric Pressure: 70KPa~106KPa
Condicions d'emmagatzematgeTemperature: -20℃~+55℃; RH: <95%; Atmospheric Pressure: 70KPa~106KPa
Pressió màxima d'inflació290 mmHg
Mètode de mesuraOscil·lometria
Mode d'operacióAutomatic continuous operation
Measurement Intervals5, 10, 15, 20, 30, 45, 60, 90, 120 min (programmable)
Measurement Range (Systolic)40-260 mmHg
Measurement Range (Diastolic)20-210 mmHg
Rang de mesura (pressió)0-290 mmHg
Measurement Range (Heart Rate)40 bpm-200 bpm
Measurement Accuracy (Pressure)± 3 mmHg
Measurement Accuracy (Pulse)± 3 ppm
Memòria internaFins a 300 lectures
Connexió de dadesCable de dades USB
Nivell de soroll45 dB
Protecció d'entradaIP22
Durada de la bateriaSupports 200 measurements per charge
Temps de càrrega2.5 hores
Capacitat nominal1000 mAh
Font d'alimentació3.7V Li battery
Wellue ABPM device with logos for European Society of Hypertension (ESH), British and Irish Hypertension Society (BIHS), Dabl Educational Trust, and Stride BP.

Image 7.1: Clinical accuracy certifications for the Wellue ABPM.

8. Garantia i Suport

8.1 Informació de la garantia

The Wellue 24-Hour Ambulatory Blood Pressure Monitor comes with a three-year warranty from the date of purchase. This warranty covers manufacturing defects and ensures reliable operation under normal use. Please retain your proof of purchase for warranty claims.

8.2 Atenció al client

For technical assistance, troubleshooting, calibration services, or warranty inquiries, please contact Wellue customer support. Contact details can typically be found on the Wellue official website or within the full user manual provided on the USB disk.

Documents relacionats - WBP02A

Preview Manual d'usuari del monitor automàtic de pressió arterial del braç superior Wellue BP2A
Manual d'usuari del monitor automàtic de pressió arterial del braç superior Wellue BP2A, que proporciona instruccions sobre la configuració, l'ús, el manteniment i la resolució de problemes. Inclou precaucions de seguretat i especificacions del producte.
Preview Wellue AirBP 2 Blood Pressure Monitor User Manual - Operation and Specifications
Comprehensive user manual for the Wellue AirBP 2 Blood Pressure Monitor. Learn how to use, charge, connect to the app, interpret readings, and find specifications. Includes troubleshooting and maintenance.
Preview Manual Utente: Monitor Automatico Presssione Arteriosa da Braccio Wellue BP2/BP2A
Manual d'usuari detaglligat per al monitor automàtic de la pressió arterial del braç Wellue BP2/BP2A. Inclou instruccions per a la mesura de la pressió sanguínia, registre ECG, aplicació de connexió, manteniment i característiques tècniques.
Preview Guia ràpida del monitor automàtic de pressió arterial del braç superior Wellue BP2/BP2A
This quick guide provides essential information for using the Wellue BP2/BP2A Automatic Upper Arm Blood Pressure Monitor. Learn about its features, how to measure blood pressure and ECG, charge the device, use the ViHealth app, and view especificacions.
Preview Guia ràpida del monitor automàtic de pressió arterial del braç superior Wellue BP2/BP2A
Guia ràpida per al monitor automàtic de pressió arterial del braç superior Wellue BP2/BP2A, que cobreix el dispositiuview, mesurament de la pressió arterial, enregistrament d'ECG i descàrrega d'aplicacions. Admet anglès, alemany, italià, castellà i francès.
Preview Manual d'usuari del monitor automàtic de pressió arterial del braç superior Wellue BP2
Manual d'usuari complet per al monitor automàtic de pressió arterial del braç superior Wellue BP2, que detalla les seves característiques, funcionament, pautes de seguretat i manteniment per a un control precís de la salut.