ECOELER YWT102

ECOELER YWT102 Countdown Timer Switch User Manual

Model: YWT102

Introducció

This manual provides comprehensive instructions for the installation, operation, and maintenance of your ECOELER YWT102 Countdown Timer Switch. This in-wall timer switch is designed to automatically turn off connected loads such as lights, ceiling fans, bathroom fans, and heaters after a preset time, contributing to energy savings and convenience. It features multiple preset countdown options and a manual override function.

ECOELER Countdown Timer Switch (Ivory, 2-Pack)

Image: The ECOELER Countdown Timer Switch in Ivory, shown as a 2-pack.

Característiques del producte

  • 8 Pre-Set Options: Offers countdown settings of 1 minute, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 60 minutes, 2 hours, or 4 hours.
  • Anulació manual: Allows instant ON/OFF control, overriding any active countdown.
  • Estalvi d'energia: Automatically turns off loads, preventing accidental energy waste. Ideal for lights, ceiling fans, bathroom fans, and heaters.
  • Operació senzilla: Features Countdown mode and Constant On mode. Select time with a button press; hold ON/OFF for 5 seconds to activate Constant On.
  • Indicador LED: An always-on LED light makes the switch easy to locate in low-light conditions.
  • Aplicació àmplia: Suitable for bathrooms, closets, pantries, garages, laundry rooms, spas, and enclosed patios.
  • Segur i fiable: ETL listed, supporting LED/CFL, Incandescent (800W), Fluorescent (1200VA) light bulbs, and motors (1/2 HP).
ECOELER Countdown Timer Switch Product Features

Imatge: Detallada view of the ECOELER Countdown Timer Switch buttons and LED indicator labels, highlighting its features.

Contingut del paquet

Upon opening your ECOELER Countdown Timer Switch package, you should find the following items:

  • ECOELER YWT102 Countdown Timer Switch
  • Matching Wall Plate
  • Filferro
  • Manual d'instruccions d'instal·lació
ECOELER Countdown Timer Switch Package Contents and Dimensions

Image: The ECOELER Countdown Timer Switch, wire nuts, and face plate, along with product dimensions.

Informació de seguretat

ADVERTIMENT: To prevent serious injury or death from electric shock, always turn OFF the power at the circuit breaker or fuse box before wiring. This device is intended for installation in accordance with the National Electric Code and local regulations. Use copper wires only. If you are unsure about any part of these instructions, consult a qualified electrician.

Especificacions

EspecificacióValor
MarcaECOELER
Número de modelYWT102
ColorMarfil
Dimensions del producte4.19 x 3.71 x 11.99 cm
Potència/Wattage1800 watts
MaterialCopper, Metal, Polycarbonate
Pes de l'article136 g
Mode d'operacióON-OFF
Valoració actual15 Amps
Vol. Operatiutage120 volts (CA)
Tipus de contacteNormalment obert
Tipus de canviPulsador
TerminalWiring Lead

Instal·lació

Follow these steps carefully to install your ECOELER Countdown Timer Switch. If you are not comfortable performing electrical work, please consult a qualified electrician.

Preinstal·lació

  1. Apagueu l'alimentació: Locate your circuit breaker panel and turn off the power to the switch box where you will be installing the timer. Verify that the power is off using a voltage provador.
  2. Elimina l'interruptor existent: Carefully remove the screws holding the existing wall plate and switch. Gently pull the switch out of the wall box.
  3. Identificar els cables: Identify the wires connected to your existing switch. Typically, you will find:
    • Hot Wire: Usually black, brings power from the circuit breaker.
    • Cable de càrrega: Usually black or red, carries power to the light/fan.
    • Fil neutre: Normalment blanc. A neutral wire is required for this timer switch.
    • Cable de terra: Usually green or bare copper.

Connexions de cablejat

Connect the wires from the wall box to the ECOELER Countdown Timer Switch as follows:

Wiring diagram for ECOELER Countdown Timer Switch

Image: Wiring diagram for the ECOELER Countdown Timer Switch, illustrating connections for Load (Red), Hot (Black), Ground (Green), and Neutral (White) wires. Note: Neutral Wire Must Be Required.

  1. Connecteu el Fil vermell from the timer to the Cable de càrrega from the wall box using a wire nut.
  2. Connecteu el Fil negre from the timer to the Filferro calent from the wall box using a wire nut.
  3. Connecteu el Fil blanc from the timer to the Fil neutre from the wall box using a wire nut.
  4. Connecteu el Fil verd from the timer to the Cable de terra from the wall box using a wire nut.

Post-instal·lació

  1. Carefully push all wires back into the wall box.
  2. Secure the timer switch to the wall box with the provided screws.
  3. Attach the new wall plate over the timer switch.
  4. Restaura l'alimentació: Return to your circuit breaker panel and turn the power back ON.

Instruccions de funcionament

The ECOELER Countdown Timer Switch offers two primary operating modes: Countdown Mode and Constant On Mode.

Mode de compte enrere

To activate a countdown:

  1. Press the desired time button (1 Min, 5 Min, 10 Min, 15 Min, 30 Min, 60 Min, 2 Hour, or 4 Hour).
  2. The corresponding LED indicator will illuminate, and the countdown will begin.
  3. The connected load (light, fan, etc.) will turn off automatically once the selected time expires.
  4. To cancel a countdown manually, press the large ON/OFF button at the bottom.

Constant On Mode (Manual Override)

To keep the connected load continuously ON, bypassing the timer function:

  1. Press and hold the large ON/OFF button at the bottom for more than 5 seconds.
  2. The load will remain ON until the ON/OFF button is pressed again to turn it off.
ECOELER Countdown Timer Switch LED Indicators in Dark

Image: The ECOELER Countdown Timer Switch with its LED indicator illuminated, making it visible in a dark environment.

Manteniment

The ECOELER Countdown Timer Switch requires minimal maintenance. To ensure optimal performance and longevity:

  • Keep the switch and wall plate clean by wiping with a soft, damp drap. Eviteu productes de neteja o dissolvents abrasius.
  • Assegureu-vos que l'interruptor no estigui exposat a una humitat excessiva ni a temperatures extremes.
  • Periodically check the connections for any signs of loosening, though this should only be done with the power turned off at the circuit breaker.

Resolució de problemes

If you encounter issues with your ECOELER Countdown Timer Switch, consider the following:

  • L'interruptor no respon: Ensure the power is ON at the circuit breaker. Check all wire connections for tightness.
  • Load Not Turning Off: Verify that the switch is not in Constant On mode (manual override). If it is, press the ON/OFF button to turn it off.
  • L'indicador LED no s'encén: Check power supply and connections. If the switch is functioning otherwise, the LED might be faulty, but this is rare.
  • Funcionament intermitent: Ensure all wire connections are secure. Loose connections can cause inconsistent performance.

If problems persist after checking these points, please contact customer support.

Garantia i Suport

The ECOELER Countdown Timer Switch comes with a 1 any de garantia. For any questions, technical assistance, or warranty claims, please contact ECOELER customer support. You can reach us via email at SUPPORTS@ECOELER.COM. We aim to respond to all inquiries within 24 hours.

Manufacturer: ECOELER ELECTRIC INC

Documents relacionats - YWT102

Preview Manual d'instal·lació i usuari de l'interruptor de llum amb sensor de moviment ECOELER YM2108T
Guia completa per a la instal·lació, el cablejat, l'ajust i la resolució de problemes de l'interruptor de llum amb sensor de moviment ECOELER YM2108T. Les característiques inclouen detecció PIR, retard de temps i ajustos de nivell de lux.