GEYA GPS8-01

GEYA Overvoltagi UndervoltagManual d'usuari del dispositiu de protecció electrònica

Brand: GEYA | Model: GPS8-01

1. Introducció i finalview

The GEYA Overvoltagi Undervoltage Protective Device is designed to provide comprehensive protection for household equipment against voltage fluctuations. It monitors voltage and current in real-time, ensuring the safety and longevity of connected appliances.

Característiques principals:

GEYA GPS8-01 Overvoltagi Undervoltagdispositiu de protecció electrònica
Figure 1: GEYA GPS8-01 Overvoltagi Undervoltage Protective Device.

Aquesta imatge mostra la part frontal view of the GEYA GPS8-01 device, highlighting its digital display, control buttons, and terminal connections for neutral (N) and input (IN).

2. Configuració i instal·lació

Proper installation is crucial for the safe and effective operation of the device. This device is designed for DIN rail mounting. Ensure all power is disconnected before proceeding with installation.

Diagrama de cablejat:

Wiring Diagram for GPS8-01 and GPS8-02
Figure 2: Comparison of Upper Wiring and Down Wiring configurations for GPS8-01 and GPS8-02 models.

This diagram illustrates the difference between upper wiring and down wiring configurations. For the GPS8-01 (Down Wiring) model, the incoming line connects to the bottom terminals (N and 1), and the outgoing load connects to the top terminals (N and 2).

Passos d'instal·lació:

  1. Mount the device securely onto a standard DIN rail.
  2. Connect the neutral (N) and live (L) wires from the power supply to the designated input terminals (N and IN) on the device. For the GPS8-01 (Down Wiring) model, these are the bottom terminals.
  3. Connect the load wires (neutral and live) from your household equipment to the output terminals on the device. For the GPS8-01 (Down Wiring) model, these are the top terminals.
  4. Assegureu-vos que totes les connexions estiguin ben ajustades i segures per evitar contactes solts i possibles perills.
  5. Once wiring is complete, restore power to the circuit. The device will power on and display the current voltage.

Installation Demonstration Video:

This video provides a visual guide to the installation and basic operation of the GEYA Overvoltage & Undervoltage Protector (GPS8-01/02/03). It demonstrates how to connect the device to a power supply and a load, and shows the device's display in action. The video also highlights key features such as RMS measurement, settable voltage/current values, self-reset, and LED fault indicators.

3. Instruccions de funcionament

Tauler acabatview:

Panel Diagram for GPS8-01 and GPS8-02
Figure 3: Detailed Panel Diagram for GPS8-01 and GPS8-02 models.

The GPS8-01 panel features a digital display for operating voltage, an under-voltage indicator, an over-voltage indicator, and a power open/close indicator. It includes 'M' (Menu/Mode), 'Up', and 'Power' buttons for control.

Configuració de paràmetres:

Parameter Setting Guide for GPS8-01 and GPS8-02
Figure 4: Guide to setting parameters for GPS8-01 and GPS8-02 models.

To enter the parameter setting interface, press the 'M' button for 3 seconds. Use the 'Up' and 'Down' (implied by context, though only 'Up' is shown as a button) buttons to adjust values. Short press 'M' to cycle through settings: Overvoltage setting (230V-300V, factory default 275V), Undervoltage setting (145V-210V, factory default 175V), and Reset time setting (2s-900s, factory default 30s). Long press 'M' for 3 seconds to exit the setup mode and return to running mode. If no key is operated for 60 seconds, the device will automatically exit the setting interface.

4. Manteniment

The GEYA Overvoltagi Undervoltage Protective Device is designed for minimal maintenance. However, regular checks can ensure its continued optimal performance.

5. Solució De Problemes

If you encounter issues with your GEYA Overvoltagi Undervoltage Protective Device, refer to the following common troubleshooting steps:

ProblemaCausa possibleSolució
Device not powering on/display is blank.No power supply; loose wiring; internal fault.Check power source. Ensure wiring is correct and secure. If problem persists, contact support.
El dispositiu s'encén amb freqüència.Voltage outside set parameters; faulty appliance; incorrect settings.Verify actual voltage with a multimeter. Check connected appliances for faults. Review and adjust over/under voltage configuració.
Display shows error code or abnormal reading.Internal malfunction; extreme voltage condició.Note the error code. Disconnect and reconnect power. If error persists, contact support.
Device does not self-reset.Fault condition still present; reset time setting too long; internal fault.Assegureu-vos que el voltage has returned to normal range. Check the reset time setting. If necessary, manually reset by cycling power.

For issues not covered here, or if troubleshooting steps do not resolve the problem, please contact GEYA customer support.

6. Especificacions

Detailed technical specifications for the GEYA GPS8-01 Overvoltagi Undervoltage Protective Device:

ParàmetreValue (GPS8-01)
FuncióMés i sota voltage protecció
Vol. d'oferta nominaltageAC220V (L-N)
Rated Supply Frequency50/60Hz
Corrent de funcionament nominal32A, 40A, 50A, 63A, 80A (AC1) - *Note: This specific model is 40A.*
CàrregaCA màx. 3VA
Voltage Visualització
Pantalla actualNo
Més del voltage Operation Value230V ~ 300V (factory default: 275V)
Més del voltage Action Delay0.5 s
Sota el voltage Operation Value145V ~ 210V (factory default: 175V)
Sota el voltage Action Delay0.5 s
Retard d'encesa2s
Restablir l'hora2 ~ 900s (factory default: 30s)
Error de mesura≤1%
Temperatura de funcionament-20 °C a +55 °C (-4 °F a 131 °F)
Temperatura d'emmagatzematge-35 °C a +75 °C (-22 °F a 158 °F)
Mounting/DIN RailDIN rail EN/IEC 60715
Grau de ProteccióIP40 per panell frontal/terminals IP20
Posició operativaQualsevol
Overvoltage CategoriaIII.
Grau de contaminació2
Dimensions82 × 36 × 68 mm
Pes130 g
Technical Parameters Table for GPS8-01 and GPS8-02
Figure 5: Technical Parameters Table for GPS8-01 and GPS8-02 models.

This image provides a visual representation of the technical specifications, including functions, rated supply voltage, frequency, operational current, and environmental conditions.

Dimensions:

Dimensions of GEYA GPS8-01
Figure 6: Dimensions of the GEYA GPS8-01 device.

This image illustrates the physical dimensions of the device, showing its height (3.22in), width (1.41in), and depth (2.65in).

7. Garantia i Suport

GEYA products are manufactured to high quality standards. For warranty information and technical support, please refer to the official GEYA weblloc web o poseu-vos en contacte amb el vostre distribuïdor local.

Documents relacionats - GPS8-01

Preview GEYA GPS8 Voltage / Current Protector Instruction Manual
Instruction manual for GEYA GPS8 series voltage and current protectors, detailing applications, features, technical specifications, wiring diagrams, and parameter settings for protecting household electrical equipment.
Preview GEYA GPS8-10 Voltage/Current Protector Instruction Manual
Instruction manual for the GEYA GPS8-10 Voltage/Current Protector, detailing its applications, features, technical parameters, wiring, panel diagram, parameter settings, factory settings, and functional diagrams.
Preview GEYA GPS8-05 Voltage / Current Protector Instruction Manual
Instruction manual for the GEYA GPS8-05 Voltage / Current Protector, detailing its applications, features, technical specifications, parameter settings, wiring, and operational diagrams for household equipment protection.
Preview 3-Fase VoltagManual d'instruccions del protector de corrent GPS8-03
Manual d'instruccions per al GEYA 3-Phase Voltage / Protector de corrent GPS8-03, que detalla les seves aplicacions, característiques, paràmetres tècnics, configuració de paràmetres, diagrames de cablejat i funcions operatives.
Preview GEYA Smart Power Protection Product Catalogue
Comprehensive catalogue of GEYA's over/under voltage and current protectors, automatic transfer switches, and energy metering devices, featuring technical specifications, features, and installation guidance for various models.
Preview GEYA GRV8-S 3-Phase Display Voltage Manual d'instruccions del relé
Comprehensive instruction manual for the GEYA GRV8-S 3-phase display voltage relay, covering applications, features, technical specifications, wiring, parameter settings, and operational descriptions for safe and efficient use.