The BEA Falcon is a sophisticated unidirectional motion sensor engineered to optimize the performance of automatic industrial doors. This sensor is designed to detect various targets and can be configured to filter out people, allowing for vehicle-only detection. This capability helps reduce door closing cycles by ignoring cross-traffic, leading to energy savings and improved operational efficiency.

The Falcon XL model, specifically, is suitable for mounting heights between 2 meters and 3.5 meters, providing a typical detection area of 4 x 2 meters. Its robust design ensures immunity against vibrations and environmental interferences, making it ideal for demanding industrial environments.

BEA Falcon XL Industrial Door Sensor

Figura 1: Frontal view of the BEA Falcon XL Industrial Door Sensor. This image shows the compact, black housing of the sensor, designed for robust industrial applications.

2. Característiques clau

3. Components del producte

The BEA Falcon sensor consists of several key components designed for easy installation and reliable operation. Refer to the diagram below for an overview of the main parts.

BEA Falcon XL Sensor Components Diagram

Figure 2: Diagram illustrating the main components of the BEA Falcon XL sensor.

  1. Push Buttons: For basic function adjustments.
  2. Front Face: The primary detection surface.
  3. Radar Antenna: Emits and receives microwave signals.
  4. Angle Indication: Visual indicator for tilt angle adjustment.
  5. Bracket: Mounting hardware for secure installation.
  6. Cable: For power and signal connection.

4. Configuració i instal·lació

The BEA Falcon XL sensor is designed for straightforward installation. Proper mounting and wiring are crucial for optimal performance and safety. It is recommended that installation be performed by qualified personnel.

4.1 Consideracions de muntatge

4.2 Cablejat i alimentació

4.3 Configuració inicial

Basic functions can be adjusted using the integrated push buttons or a compatible remote control. Refer to the detailed product manual (not provided in this summary) for specific programming steps for features like people filtering and cross-traffic filtering.

BEA Falcon XL Detection Field Diagram

Figure 3: Illustration of the detection fields for the BEA Falcon sensor in an industrial door application. This diagram shows how the sensor can differentiate between pedestrian and vehicle traffic, optimizing door operation.

5. Funcionament

Once properly installed and configured, the BEA Falcon XL sensor operates autonomously to detect motion within its defined field. The sensor's LED indicator provides visual feedback on its status.

5.1 Mode de detecció

The sensor operates in motion detection mode. It identifies moving objects within its detection zone and triggers the door opening mechanism based on the configured parameters (e.g., presence of vehicles only).

5.2 Indicadors LED

5.3 Optimització del rendiment

To ensure optimal performance, regularly verify that the detection field is clear of obstructions and that the sensor's lens is clean. The unidirectional detection and filtering capabilities contribute to efficient door operation and energy conservation.

6. Manteniment

The BEA Falcon XL sensor is designed for minimal maintenance due to its robust construction and IP65 rating. However, periodic checks are recommended to ensure continued optimal performance.

No user-serviceable parts are inside the sensor housing. Do not attempt to open or repair the unit yourself. Contact qualified service personnel for any repairs.

7. Solució De Problemes

This section provides basic troubleshooting steps for common issues. For more complex problems, consult a qualified technician.

ProblemaCausa possibleSolució
El sensor no detecta moviment.No power; obstructed detection field; incorrect sensitivity settings; sensor malfunction.Check power supply and connections. Clear any obstructions. Adjust sensitivity settings. If problem persists, contact support.
Door opens for unwanted traffic (e.g., pedestrians).People filter not activated or incorrectly configured; cross-traffic filter not active.Verify and adjust the people filter and cross-traffic filter settings using push buttons or remote control.
L'indicador LED no s'il·lumina.No power; faulty LED; internal issue.Check power supply. If power is present and LED remains off, the unit may require service.
Intermittent detection.Loose wiring; environmental interference; sensor position shifted.Inspect wiring connections. Ensure sensor is securely mounted and not vibrating. Check for new sources of interference.

8. Especificacions tècniques

ParàmetreValor
TecnologiaRadar Doppler de microones
Freqüència del transmissor24.150 GHz
Potència radiada del transmissor<20 dBm EIRP
Densitat de potència del transmissor<5 mW/cm²
Mode de deteccióMoviment
Detection Zone (FALCON XL)4 x 2 m (typical at 30° and field size 9)
Min. Velocitat de detecció5 cm/s
Subministrament Voltage12 V to 24 V AC ±10% (50 - 60 Hz); 12 V to 24 V DC +30% / -10%
Consum màxim d'energia<2 W
Relé de sortidaFree of potential change-over contact
Màx. Contacte Voltage30 V AC / 42 V DC
Màx. Contacte actual1A (resistiu)
Màx. Potència de commutació30 W
Senyal LEDRed: detection state, parameter indication; Green: value indication
Mounting Height (FALCON XL)2 m - 3.5 m
Grau de proteccióIP65 (IEC/EN 60529)
Interval de temperatura-30 °C a +60 °C
Dimensions (L x A x A)127 mm x 102 mm x 96 mm
Angles d'inclinació0° to 180° vertical
MaterialsABS and Polycarbonate
Pes400 g
Longitud del cable10 o 15 m

9. Informació de seguretat

Always observe the following safety precautions during installation, operation, and maintenance of the BEA Falcon XL sensor:

10. Garantia i Suport

For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact your authorized BEA distributor. Keep your purchase receipt as proof of purchase.

Documents relacionats - 1PC BEA FALCON XL(2-3.5m)

Preview Sensor de moviment FALCON EX amb carcassa a prova d'explosió: guia de l'usuari
Guia d'usuari completa per al sensor de moviment BEA FALCON EX amb carcassa a prova d'explosió, que cobreix les especificacions tècniques, la instal·lació, el funcionament, la configuració i la resolució de problemes.
Preview Sensor d'obertura unidireccional Eagle Artek per a portes automàtiques: guia d'usuari i especificacions
Guia d'usuari completa per al sensor d'obertura unidireccional BEA Eagle Artek. Cobreix la instal·lació, les especificacions tècniques, la configuració, la resolució de problemes i el compliment de les normes per a sistemes de portes automàtiques. Model SW 0100 i posterior.
Preview Guia de l'usuari del sensor d'obertura unidireccional BEA EAGLE ARTEK
Guia d'usuari completa per al sensor d'obertura unidireccional BEA EAGLE ARTEK per a portes automàtiques, que cobreix les especificacions tècniques, la instal·lació, la configuració i la resolució de problemes.
Preview FALCON EX Sensor de moviment amb carcassa a prova d'explosions - Guia de l'usuari
Guía del usuario detallada para el sensor de movimiento FALCON EX de BEA, Inc. Cubre descripción del producto, especificaciones técnicas, señales LED, uso del control remoto y botones, consejos de instalación, cableado, dimensiones del campo de detección, configuración, solución de problemas y cumplimiento.
Preview Sensor de moviment i presència BEA IXIO-DT1 per a portes corredisses automàtiques - Manual d'usuari
Guia completa per al sensor de moviment i presència BEA IXIO-DT1, que cobreix la instal·lació, la configuració, les especificacions tècniques i la resolució de problemes per a portes corredisses automàtiques.
Preview BEA LZR-WIDESCAN Mechanical Installation Guide: Mounting and Wiring
Comprehensive mechanical installation guide for the BEA LZR-WIDESCAN opening, presence, and safety sensor for industrial doors. Covers technical specifications, mounting, wiring, detection field setup, troubleshooting, and usage instructions.