ACiQ ACiQ-18-AC

ACiQ Brand Logo Banner

ACiQ 1.5 Ton 16 SEER2 Central Air Conditioner System

Model: ACiQ-18-AC

1. Introducció

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your ACiQ 1.5 Ton 16 SEER2 High Efficiency Central Air Conditioner System. Please read this manual thoroughly before attempting any procedures. Proper installation and maintenance are crucial for optimal performance and longevity of the unit.

ACiQ 1.5 Ton Central Air Conditioner System with Installation Kit

Imatge 1.1: acabatview of the ACiQ 1.5 Ton Central Air Conditioner System and included installation kit.

2. Informació de seguretat

WARNING: Installation and servicing of this equipment can be hazardous due to system pressure, electrical components, and sharp edges. Only qualified, trained, and licensed HVAC technicians should install, repair, or service this equipment. Failure to follow this warning could result in property damage, personal injury, or death.

  • Always disconnect power to the unit before performing any maintenance or service.
  • Utilitzeu l'equip de protecció individual (EPI) adequat, incloent-hi guants i protecció ocular.
  • Ensure proper grounding of all electrical components.
  • No feu funcionar la unitat amb cables o components elèctrics danyats.
  • Mantingueu els nens i les mascotes allunyats de la unitat durant el funcionament i el manteniment.

3. Contingut del paquet

Verifiqueu que tots els components que s'enumeren a continuació siguin presents al vostre paquet:

  • Unitat condensadora exterior
  • Indoor Evaporator Cased Coil (Multi-Positional)
  • Termòstat WiFi intel·ligent
  • 30' Insulated Line Set (3/8" LL x 3/4" SL x 3/8")
  • 1/2" x 6' 10 Gauge Electrical Whip
  • 60A Non-fused Disconnect Switch
  • Controls Surge Protector
  • CPS Charging Adapter
  • Màniga de paret
  • Suport de muntatge a la paret
  • Manual d'usuari (aquest document)
Complete ACiQ Split System Installation Kit Components

Image 3.1: Components included in the ACiQ Split System Installation Kit.

4. Producte acabatview i Característiques

4.1. Inverter AC Technology

The ACiQ system utilizes inverter technology, which allows the compressor to adjust its speed continuously. This precise control maintains a consistent indoor temperature, reduces energy consumption, and results in quieter operation compared to traditional single-stagsistemes electrònics.

4.2. Multi-Positional Evaporator Cased Coil

The included cased coil is designed for multi-positional installation, offering flexibility for various HVAC system configurations. It features a factory-integrated TXV (Thermostatic Expansion Valve) for optimized refrigerant flow and enhanced system efficiency.

4.3. Smart Thermostat

The system comes with a Smart WiFi Thermostat, enabling remote control and advanced scheduling features. It integrates with popular smart home platforms for convenient management of your home's climate.

ACiQ Air Conditioner Features Overview

Image 4.1: Key features of the ACiQ Air Conditioner, including inverter technology, gold fin coil, and quiet operation.

Smart Thermostat Features and Interface

Image 4.2: Detailed features and interface of the included Smart Thermostat.

5. Especificacions

EspecificacióValor
Nom de marcaACiQ
Informació del modelACiQ-18-AC / ACIQ-24-ACL / IKIC31
Capacitat1.5 Tons (18000 BTU/h)
Classificació SEER2Fins a 16.8
Voltage230 Volts
Wattage1538 watts
Tipus d'instal·lacióSistema dividit
Factor de formaCentral Split System
Característiques especialsInverter Unit, Smart Sensors, Gold Fin Coil, Ultra-Quiet, All-Climate Performance
Cobertura de la superfície del sòlFins a 900 peus quadrats
Outdoor Condenser Dimensions (D x W x H)13.46 x 35.04 x 26.5 polzades
Dimensions de la serpentina de l'evaporador (amplada x profunditat x alçada)17.52 x 20.98 x 17.99 polzades
Evaporator Coil Air Flow720.04 CFM
Evaporator Coil Dehumidification3.02
ACiQ Outdoor Condenser and Evaporator Coil Dimensions

Image 5.1: Dimensional measurements for the ACiQ outdoor condenser and evaporator coil.

ACiQ Evaporator Coil Specifications

Image 5.2: Detailed specifications for the ACiQ evaporator coil.

6. Configuració i instal·lació

IMPORTANT: This ACiQ Central Air Conditioner System requires professional installation by a qualified and licensed HVAC technician. Attempting to install the system without proper training and tools can lead to property damage, personal injury, voided warranty, and improper operation.

6.1. Comprovacions prèvies a la instal·lació

  1. Ensure the installation site meets local building codes and regulations.
  2. Verify that the electrical supply matches the unit's requirements (230 Volts).
  3. Confirm adequate space for both the outdoor condenser and indoor evaporator coil, allowing for proper airflow and service access.

6.2. Passos d'instal·lació (més enllà)view per a tècnic)

  1. Mounting the Outdoor Condenser: Securely mount the outdoor unit using the provided wall mount bracket or a suitable ground-level pad, ensuring proper drainage and vibration isolation.
  2. Installing the Indoor Evaporator Coil: Integrate the multi-positional cased coil with your existing furnace or air handler, ensuring proper sealing and airflow.
  3. Connexió de les línies de refrigerant: Connect the insulated line set between the outdoor and indoor units. This involves brazing and vacuuming the lines to remove moisture and non-condensable gases, followed by charging with R410A refrigerant.
  4. Cablejat elèctric: Connect the electrical whip, disconnect switch, and controls surge protector according to wiring diagrams provided with the unit and local electrical codes. Connect the smart thermostat.
  5. System Start-up and Testing: Perform a leak check, verify proper refrigerant charge, test all operational modes, and calibrate the thermostat.

7. Instruccions de funcionament

Once professionally installed, your ACiQ system is designed for user-friendly operation primarily through the Smart WiFi Thermostat.

7.1. Smart Thermostat Operation

Refer to the separate Smart WiFi Thermostat manual for detailed instructions on its features, including:

  • Setting desired temperature (cooling/heating set points).
  • Selecting operating modes (Cool, Heat, Auto, Fan Only).
  • Programming schedules and presets.
  • Connecting to your home's WiFi network for remote access via a mobile application.
  • Integration with voice assistants (e.g., Alexa, Google Assistant) and smart home platforms (e.g., SmartThings, IFTTT).

7.2. Inverter Technology Benefits

The inverter system automatically adjusts its output to match the cooling demand, providing consistent comfort and energy savings. You may notice the compressor running at varying speeds, which is normal operation for an inverter unit.

8. Manteniment

Regular maintenance ensures the efficiency and longevity of your ACiQ system. Some tasks can be performed by the homeowner, while others require a professional technician.

8.1. Manteniment d'usuaris

  • Clean or Replace Air Filters: Check your furnace/air handler's air filter monthly and clean or replace it as needed. A dirty filter restricts airflow and reduces efficiency. The system uses a washable, reusable mesh filter.
  • Clear Outdoor Unit: Keep the area around the outdoor condenser unit free from debris, leaves, and vegetation to ensure proper airflow.
  • Clean Evaporator Coil Drain Pan: Periodically check and clean the condensate drain pan to prevent clogs and water overflow.

8.2. Manteniment professional

Schedule annual maintenance with a qualified HVAC technician. This typically includes:

  • Checking refrigerant levels and pressure.
  • Cleaning condenser and evaporator coils.
  • Inspecció de connexions i components elèctrics.
  • Lubricació de les peces mòbils (si escau).
  • Checking thermostat calibration.
  • Inspecting ductwork for leaks.

9. Solució De Problemes

Abans de trucar al servei, review aquests problemes i solucions comuns:

ProblemaCausa possibleSolució
El sistema no refreda/escalfaThermostat setting incorrect, dirty air filter, power supply issue, tripped breaker.Check thermostat settings, replace/clean filter, check circuit breaker, ensure power is on.
Flux d'aire deficientDirty air filter, blocked vents, obstructed outdoor unit.Clean/replace filter, ensure vents are open, clear debris from outdoor unit.
Sorolls inusualsLoose parts, debris in fan, refrigerant issues.Inspect for loose panels or debris. If persistent, contact a technician.
Fuga d'aiguaClogged condensate drain line, frozen evaporator coil.Clear drain line. If coil is frozen, turn off unit and contact a technician.

If these steps do not resolve the issue, contact a qualified HVAC technician for further diagnosis and repair.

10. Garantia i Suport

10.1. Condicions de garantia

Your ACiQ Central Air Conditioner System comes with a warranty of 7 anys en peces i 12 years on the compressor. This warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer. Please retain your proof of purchase and installation records.

10.2. Atenció al client

For technical assistance, warranty claims, or to locate a certified service provider, please visit the official ACiQ website or contact their customer support line. (Specific contact details are typically provided on the manufacturer's website or warranty card.)

11. AHRI Rating Conditions

AHRI (Air-Conditioning, Heating, and Refrigeration Institute) certification is essential for HVAC units as it assures performance, energy efficiency, quality, regulatory compliance, and provides benefits like market differentiation, financial incentives, and consumer protection.

AHRI Certified Rating and EnergyGuide Label for ACiQ System

Image 11.1: AHRI Certification and EnergyGuide label details for the ACiQ system, showing SEER2 rating and cooling capacity.

The manufacturer of this ACiQ product is responsible for the rating of this system combination. The unit is rated as follows in accordance with the latest edition of AHRI 210/240-2024, Performance Rating of Unitary Air-Conditioning & Air-Source Heat Pump Equipment:

  • AHRI Certified Number: 214731227
  • Data: 08-26-2024
  • Model Status: Actius
  • AHRI Type: RCU-A-C (Split System: Air-Cooled Condensing Unit, Coil Alone)
  • Nom de marca: ACiQ
  • Unitat exterior: ACiQ-18-AC
  • Unitat interior: ACiQ-24-ACL
  • Cooling Capacity BTU/h: 18000
  • SEER2: 16.00
  • EER2 Single or High Stage: 11.70

Documents relacionats - ACiQ-18-AC

Preview Manual d'instal·lació de la unitat exterior dels sistemes d'inversor central ACiQ
Manual d'instal·lació complet per a les unitats exteriors dels sistemes d'inversor central ACiQ, que cobreix les precaucions de seguretat, les canonades de refrigerant, la instal·lació de la unitat exterior, el cablejat, les especificacions d'alimentació, l'evacuació de l'aire i els procediments de prova de funcionament. Inclou detalls del model i notes importants per a una configuració correcta.
Preview Manual d'instal·lació dels sistemes d'inversor central ACiQ
Manual d'instal·lació complet per als sistemes d'aire condicionat i bomba de calor amb inversor central ACiQ, que detalla les precaucions de seguretat, les canonades de refrigerant, la instal·lació de la unitat exterior, el cablejat, les especificacions d'alimentació, l'evacuació de l'aire i els procediments de prova de funcionament.
Preview Manual d'instal·lació de la unitat exterior dels sistemes d'inversor central ACiQ
Manual d'instal·lació complet per a les unitats exteriors dels sistemes d'inversor central ACiQ, que cobreix les precaucions de seguretat, les canonades de refrigerant, el cablejat, la instal·lació de la unitat i els procediments de prova per a models com ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB i altres.
Preview Manual d'instal·lació del controlador d'aire per conductes ACiQ (12K-60K BTU/h)
Aquest manual d'instal·lació d'ACiQ proporciona instruccions detallades per a la instal·lació segura i correcta d'unitats de tractament d'aire per conductes, models de 12 a 60 BTU/h. Cobreix les directrius de seguretat essencials, la col·locació de la unitat, les canonades de refrigerant, el cablejat elèctric, les especificacions i les proves de funcionament per garantir un rendiment òptim i una longevitat del sistema.
Preview Manual d'instal·lació del condensador monozona i del controlador d'aire per conductes ocults ACiQ Extreme Heat
Manual d'instal·lació per als sistemes de tractament d'aire de conductes ocults i condensadors de zona única ACiQ Extreme Heat (models ACIQ-09CD-HH-MC a ACIQ-60CD-HH-MC i ACIQ-09ZPL-HP230C a ACIQ-60ZPL-HP230C). Inclou informació de seguretat, passos d'instal·lació i especificacions.
Preview Manual del propietari del controlador d'aire per conductes ACiQ Extreme+
Manual d'usuari complet per al controlador d'aire per conductes ACiQ Extreme+ (18K-60K), que cobreix les precaucions de seguretat, les peces, el manteniment i la resolució de problemes.