ELEGRP G1215PA2 G20PASR

ELEGRP G1215PA2 G20PASR GFCI Replacement Plug Assembly User Manual

Brand: ELEGRP | Model: G1215PA2 G20PASR

Introducció

The ELEGRP G1215PA2 G20PASR Patented Auto-Monitoring GFCI Replacement Plug Assembly is designed to provide enhanced electrical safety by protecting against ground faults. This auto-reset, 15 Amp, non-grounded plug is suitable for a variety of indoor and outdoor applications, including power pressure washers and pool pumps. It features advanced auto-monitoring capabilities and is UL/CUL Listed, ensuring reliable performance and user protection.

ELEGRP G1215PA2 G20PASR GFCI Replacement Plug Assembly

Figure 1: ELEGRP G1215PA2 G20PASR GFCI Replacement Plug Assembly.

Informació de seguretat

Your safety is paramount. This GFCI plug is designed with multiple safety features to protect against electrical hazards. It is UL and CUL Listed, confirming its compliance with rigorous safety standards.

  • Patented Auto-Monitoring: The device automatically conducts a self-test every 5 seconds, exceeding the UL standard of 3 hours, to ensure continuous protection against electrocution.
  • Surge and Lightning Protection: Withstands 6 kilovolt surges, providing additional protection for connected appliances.
  • Resistent a l'aigua: Reaches Level IP65 water resistance, exceeding UL 50E-3R, making it suitable for damp o ambients humits.
  • Construcció duradora: Made from high-strength thermoplastic for enhanced durability and impact resistance.
Child near electrical outlet, emphasizing electrical safety

Figure 2: Always prioritize electrical safety, especially around children.

Instruccions d'instal·lació

This GFCI replacement plug is designed for easy installation with screw terminals, eliminating the need for soldering. It is a non-grounded, 2-wire, 2-prong assembly.

Eines necessàries:

  • Tornavís
  • Pelafils

Passos d'instal·lació:

  1. Prepara el cable: Carefully cut and strip the insulation from the end of your appliance's power cord, exposing the two internal wires. Ensure approximately 1/2 inch of bare wire is exposed.
  2. Stripping wire for GFCI plug installation

    Figure 3: Stripping the power cord wires.

  3. Open the Plug Assembly: Unscrew and carefully open the GFCI plug assembly to access the internal wiring terminals.
  4. Connecteu els cables: Insert each stripped wire into its corresponding screw terminal. Tighten the screws securely to ensure a firm electrical connection. This model does not require a grounding wire.
  5. Connecting wires to GFCI plug terminals

    Figure 4: Connecting wires to the terminals.

  6. Assegureu el cable: Utilize the provided grommets (2 different sizes for 14AWG, 16AWG, and 18AWG cables) to secure the cable firmly where it enters the plug housing.
  7. Close the Assembly: Carefully close the plug assembly, ensuring no wires are pinched. Secure it with the screws.
  8. Closing the GFCI plug housing

    Figure 5: Closing the plug assembly.

    Securing the GFCI plug with a screw

    Figure 6: Securing the plug assembly.

  9. Initial Plug-in: After installation, it is necessary to press the Botó de restabliment for initial power-up.

Operating the GFCI Plug

The ELEGRP GFCI plug is designed for simple and effective operation, ensuring continuous safety.

Self-Test and Auto-Monitoring:

This GFCI outlet automatically conducts a self-test (auto-monitor) every 5 seconds to ensure it is continually working to protect people from electrocution. A green LED indicator light shows when there is power and the unit is functioning correctly.

GFCI plug automatically self-testing every 5 seconds

Figure 7: The GFCI plug performs an automatic self-test every 5 seconds.

Botons de prova i restabliment:

The GFCI plug features two buttons: a PROVA button and a RESET button. These buttons allow you to manually verify the GFCI's functionality and restore power after a trip.

  • Botó TEST: Press this button to simulate a ground fault. The GFCI should trip, cutting off power to the connected device, and the LED indicator will turn off.
  • Botó de reset: After a trip (either from a ground fault or a test), press this button to restore power. The LED indicator should illuminate green, indicating normal operation.

Vídeo 1: Un overview of the ELEGRP GFCI G20 Series, demonstrating its features including self-test, durability, and various types of GFCI plugs.

Manteniment

To ensure the longevity and continued safe operation of your ELEGRP GFCI plug, follow these maintenance guidelines:

  • Proves periòdiques: Perform a manual test using the TEST button monthly to ensure the GFCI is functioning correctly.
  • Mantenir net: Wipe the exterior of the plug with a dry, clean cloth. Avoid using abrasive cleaners or solvents.
  • Inspeccionar per danys: Periodically check the plug and cord for any signs of damage, such as cracks, fraying, or discoloration. If damage is found, discontinue use and replace the unit.
  • Protegir dels elements: Although water-resistant, avoid prolonged exposure to extreme weather conditions. When used outdoors, ensure it is protected within a suitable weatherproof enclosure if not directly connected to a weatherproof outlet.
  • Outdoor electrical outlet with weatherproof cover

    Figura 8: Example of a weatherproof cover for outdoor electrical outlets.

Resolució de problemes

If your GFCI plug is not functioning as expected, refer to the following common issues and solutions:

ProblemaCausa possibleSolució
GFCI will not reset (no power)No power to the outlet; internal fault; damaged unit.Check the circuit breaker. Ensure the outlet is live. If the problem persists, the unit may be faulty and require replacement.
El GFCI s'activa amb freqüènciaGround fault in the connected appliance or wiring; overloaded circuit.Unplug the appliance and try resetting. If it resets, the appliance may have a fault. If it trips with no appliance, check the wiring. Reduce load on the circuit.
LED indicator is off, but power is presentEl GFCI s'ha disparat.Premeu el botó RESET button. If it does not reset, refer to "GFCI will not reset" above.

Especificacions

Detailed technical specifications for the ELEGRP G1215PA2 G20PASR GFCI Replacement Plug Assembly:

CaracterísticaEspecificació
Certificació de seguretatUL, CUL Certification
Temperatura de funcionament-31 a 150 °F (-35 a 66 °C)
Voltage125Vac
Corrent nominalGFCI 15A
Freqüència nominal60 Hz
Rated Residual Operating Current4mA ~ 6mA
Standard Cord Set Compatibility16AWGx3C or 14AWGx2C, 18AWGx3C/2C or 16AWGx2C
Restableix el tipusRestabliment automàtic
Dimensions del producte4.67"D x 2.05"W x 1.54"H (118.5x52x39mm)
Product specification table for ELEGRP GFCI plug

Figure 9: Visual representation of product specifications.

Aplicacions

The ELEGRP GFCI Replacement Plug Assembly is versatile and suitable for a wide range of applications, both indoors and outdoors, where electrical safety is critical:

  • Power Pressure Washers
  • Bombes de piscina
  • Generadors
  • Aspiradores
  • Escalfadors
  • Household Electrical Appliances
  • Carregadors
Various applications for GFCI plug including pressure washer, pool pump, generator, vacuum cleaner, heater, and household appliances

Figure 10: Common applications for the GFCI plug.

GFCI plug used with a hot tub, pressure washer, and cooler

Figure 11: The GFCI plug is ideal for devices like hot tubs and pressure washers.

Garantia i Suport

ELEGRP is committed to providing high-quality products and customer satisfaction. This product comes with 3 years of product support.

For technical assistance, troubleshooting, or warranty claims, please contact ELEGRP customer support through their official channels.

Trusted and Reliable: 20 Years Focus on Electrical Safety Products, UL Listed, 3 Years of Product Support

Figure 12: ELEGRP's commitment to product quality and support.

Documents relacionats - G1215PA2 G20PASR

Preview Guia d'instal·lació de l'interruptor de llum intel·ligent ELEGRP
Aquest document proporciona instruccions d'instal·lació per a l'interruptor de llum intel·ligent ELEGRP, que cobreix les configuracions unipolars i de 3 vies. Detalla el cablejat, la configuració i la compatibilitat amb assistents domèstics intel·ligents com ara Alexa i Google Assistant.
Preview Resolució de problemes de l'endoll intel·ligent ELEGRP: resoldre errors de connexió de l'aplicació
Guia completa per a la resolució de problemes i errors de connexió d'APP per a endolls intel·ligents ELEGRP. Apreneu a comprovar la freqüència Wi-Fi, el mode d'emparellament, els modes de connexió, la configuració del telèfon i la intensitat del senyal.
Preview Manual d'usuari de l'endoll intel·ligent ELEGRP Matter
Manual d'usuari de l'endoll intel·ligent ELEGRP Matter (model MP10), que cobreix la introducció del producte, les especificacions, les opcions de configuració mitjançant l'aplicació ELEGRP HOME o aplicacions de tercers compatibles amb Matter, la resolució de problemes comuns, les instruccions de seguretat importants, les declaracions de compliment de la FCC i l'ISED Canadà i la garantia limitada d'un any.
Preview Manual d'usuari del dispositiu domèstic intel·ligent ELEGRP: Connexió d'aplicacions i dispositius
Manual d'usuari complet per a dispositius domèstics intel·ligents ELEGRP, que detalla com descarregar l'aplicació ELEGRP HOME, connectar dispositius mitjançant Wi-Fi (només 2.4 GHz) i integrar-los amb Amazon Alexa i Google Assistant.
Preview Instruccions d'instal·lació del carregador USB / endoll combinat
Instruccions d'instal·lació per al carregador combinat / endoll USB, que detallen les característiques, les especificacions, la compatibilitat i els diagrames de cablejat. Inclou avisos i precaucions de seguretat.
Preview Butlletí del producte del sensor d'ocupació i desocupació ELEGRP
Butlletí de producte per al sensor d'ocupació i desocupació d'ELEGRP, que detalla les característiques, els avantatges i les especificacions dels models de sensors d'ocupació i desocupació.