1. Introducció
The Pedrollo TOP 2 submersible pump is designed for pumping clear water without abrasive particles. This 0.5 HP, 115 Volt pump is engineered for ease of use and reliable operation, featuring total motor cooling and a double mechanical seal on the shaft for enhanced safety and durability.
It is particularly suitable for emergency draining of small flooded areas such as basements, garages, and fountains, as well as for emptying containers or water tanks, and draining water from dishwashers and washing machines.
2. Informació de seguretat
Always prioritize safety when operating electrical equipment, especially with water. Read and understand all instructions before installation and use.
- Connexió elèctrica: Ensure the power supply matches the pump's specifications (115 Volts). Connect the pump to a properly grounded outlet with a residual current device (RCD) for protection against electric shock.
- Qualitat de l'aigua: This pump is designed for clear water. Do not use it for pumping flammable liquids, corrosive chemicals, or water containing large abrasive particles.
- Límits de temperatura: The maximum liquid temperature for continuous operation is +40 °C. For intermittent use, the pump can handle temperatures up to +40 °C for a maximum period of 3 minutes.
- Manipulació: Always use the integrated handle for lifting and lowering the pump. Never pull the pump by its power cable or discharge hose.
- Nens i animals de companyia: Mantingueu els nens i les mascotes allunyats de la bomba i de la zona de funcionament.
- Manteniment: Disconnect the pump from the power supply before performing any maintenance or cleaning.
3. Configuració i instal·lació
Una instal·lació correcta és crucial per al rendiment i la longevitat de la bomba.
3.1 Desembalatge i inspecció
Carefully remove the pump from its packaging. Inspect the pump for any signs of damage during transit. Ensure all components, including the 5-meter power cable and integrated float switch, are present.

Pedrollo TOP 2 Submersible Pump packaging and unit.
3.2 Connecting the Discharge Hose
Attach a suitable discharge hose to the pump's outlet. Ensure the connection is secure to prevent leaks during operation. The pump is designed to accommodate standard hose sizes.
3.3 Positioning the Pump
Place the pump on a stable, flat surface in the area to be drained. Ensure the pump is fully submerged in the water before starting. The maximum immersion depth for the TOP 2 model is 3 meters.

Pedrollo TOP 2 Submersible Pump showing the integrated handle and float switch.
3.4 Ajust de l'interruptor de flotador
The pump features an integrated float switch for automatic start and stop. The float switch activates the pump when the water level rises and deactivates it when the water level drops to a certain point. Ensure the float switch can move freely without obstruction to function correctly.
4. Funcionament
Once installed, operating the Pedrollo TOP 2 pump is straightforward.
4.1 Engegada de la bomba
After ensuring the pump is correctly positioned and submerged, plug the power cable into a suitable electrical outlet. The integrated float switch will automatically start the pump when the water level reaches the activation point.
4.2 Funcionament automàtic
The float switch will automatically turn the pump on and off based on the water level. This feature is ideal for continuous monitoring and draining of fluctuating water levels. The pump will continue to operate until the water level drops to the minimum emptying level of 14 mm from the bottom.
4.3 Parada de la bomba
To manually stop the pump, simply unplug it from the power outlet. The pump will also stop automatically once the water level falls below the float switch's deactivation point.
5. Manteniment
Un manteniment regular garanteix un rendiment òptim i allarga la vida útil de la bomba.
- Neteja: Periodically clean the pump's exterior to remove any debris or sediment. Ensure the intake area is clear of obstructions.
- Float Switch Check: Regularly check that the float switch moves freely and is not obstructed by debris.
- Inspecció de l'impel·lent: If the pump's performance decreases, inspect the impeller for blockages. The pump can handle solid particles up to Ø 10 mm. Larger particles may cause damage or blockages.
- Emmagatzematge: If storing the pump for an extended period, especially in freezing conditions, ensure it is completely drained of water to prevent damage. Store in a dry, protected area.
6. Solució De Problemes
This section addresses common issues you might encounter with your Pedrollo TOP 2 pump.
| Problema | Causa possible | Solució |
|---|---|---|
| La bomba no arrenca | Sense font d'alimentació Float switch not activated Sobrecàrrega del motor | Comproveu la connexió d'alimentació i l'interruptor automàtic Ensure water level is high enough to activate float Deixeu que el motor es refredi; comproveu si hi ha obstruccions |
| Flux d'aigua baix o nul | Discharge hose kinked or blocked Pump intake blocked Impeller damaged or clogged | Check and clear hose Clean pump intake screen Disconnect power and inspect/clean impeller |
| La bomba funciona contínuament | Float switch stuck in 'on' position Afluència d'aigua contínua | Check float switch for obstructions Verify the source of water inflow |
Si els problemes persisteixen després d'intentar aquestes solucions, poseu-vos en contacte amb personal de servei qualificat.
7. Especificacions
Technical details for the Pedrollo TOP 2 Submersible Pump.

Primer pla view of the Pedrollo TOP 2 Submersible Pump, highlighting the technical label.
- Model: TOP 2
- Potència: 0.5 CV
- Voltage: 115 Volts
- Profunditat màxima d'immersió: 3 metres
- Temperatura màxima del líquid: +40 °C (for max 3 minutes)
- Sphere Passage (Max Particle Size): Ø 10 mm
- Maximum Emptying Level: 14 mm from the bottom
- Material: Ferro colat
- Font d'alimentació: Electric cable (5m length supplied)
- Components inclosos: Integrated float for automatic start/stop
- Dimensions (paquet): 31.6 x 20.9 x 19.5 cm
- Pes (paquet): 5.32 kg
- Alçada màxima d'elevació: 3 metres
8. Vídeos oficials de productes
No official product videos specifically for the Pedrollo TOP 2 submersible pump from a 'Seller' creator type were found in the provided data. The available video is for a different product (Truper submersible pump) and is therefore not included.
9. Garantia i Suport
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact Pedrollo customer service directly. Keep your purchase receipt as proof of purchase.