1. Introducció
This manual provides comprehensive instructions for the safe and efficient operation, setup, maintenance, and troubleshooting of your Pulsar GD10KBN 10500W Dual Fuel Portable Inverter Generator. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.
The Pulsar GD10KBN is designed to provide reliable portable power for residential backup, camping, and job site applications. It features dual-fuel capability, allowing operation on either gasoline or propane, and delivers 10,500 peak watts and 8,000 running watts.
2. Informació de seguretat
WARNING: Improper operation of this generator can result in serious injury or death. Always follow all safety precautions.
- Perill de monòxid de carboni: Generators produce carbon monoxide, an odorless, colorless gas that can kill you. Operate the generator outdoors only, far away from windows, doors, and vents.
- Perill d'incendi: Gasoline and propane are highly flammable. Do not refuel while the engine is running or hot. Store fuel in approved containers in a well-ventilated area.
- Perill de descàrrega elèctrica: Do not operate the generator in wet conditions. Ensure all electrical connections are secure and properly grounded. Overload protection and short circuit protection features are integrated, but proper usage is essential.
- Superfícies calentes: The generator engine and muffler become very hot during operation and remain hot for a period after shutdown. Avoid contact with hot surfaces.
- Llegeix el manual: Familiarize yourself with all controls and safety decals before operating.
- Materials perillosos: Transportation of this item is subject to hazardous materials regulations. Handle with care.
3. Producte acabatview
The Pulsar GD10KBN is a robust dual-fuel inverter generator designed for versatility and efficiency. Key components and features are detailed below.
3.1 Característiques clau
- Capacitat de doble combustible: Operates on gasoline or propane.
- Sortida d'alta potència: 10,500 Peak Watts / 8,000 Running Watts (Gasoline); 9,400 Peak Watts / 7,200 Running Watts (Propane).
- Tecnologia inversor: Provides clean power suitable for sensitive electronics.
- Multímetre digital: Mostra voltage, frequency, total hours run, and hours until recommended maintenance.
- Preparat per a autocaravana: Equipped with a 15-50R outlet for recreational vehicle use.
- Low Idle Control: Maximizes run times and fuel efficiency.
- Voltage Selecció: Supports 120V or 240V output.
- Portabilitat: Integrated wheels and handles for easy transport.
- Característiques de seguretat: Automatic Shut Down, Automatic Voltage Regulation, Low Oil Shutdown, Overload Protection, Short Circuit Protection.
3.2 Identificació de components

Figura 3.2.1: Frontal view of the Pulsar GD10KBN generator, showing the control panel, outlets, and fuel input.

Figura 3.2.2: Detallada view of the control panel, highlighting the parallel ready outlets, electric start switch, and LPG inlet for propane connection.

Figura 3.2.3: posterior view of the generator, illustrating the engine, exhaust, and propane regulator connection point.
4. Configuració
Before operating your generator, proper setup is essential for safety and performance.
4.1 Desembalatge i muntatge
- Carefully remove the generator from its packaging. The unit is heavy and may require two people to lift or a ramp for removal from a pallet.
- Attach the wheels and handles according to the instructions provided in the separate assembly guide.
4.2 Afegir oli de motor
The generator is shipped without engine oil. You must add the correct amount and type of oil before the first start.
- Col·loqueu el generador sobre una superfície plana.
- Localitzeu el tap/vareta d'ompliment d'oli.
- Add the recommended engine oil (e.g., 5W-30 synthetic) to the crankcase until it reaches the upper mark on the dipstick. Do not overfill.
4.3 Fuel Connection
The GD10KBN operates on either gasoline or propane.
- For Gasoline Operation:
- Assegureu-vos que el generador estigui apagat i fred.
- Fill the fuel tank with fresh, unleaded gasoline (minimum 87 octane). Do not overfill.
- For Propane Operation:
- Connect a standard 20lb (or larger) propane tank to the LPG inlet on the generator using the provided hose.
- Assegureu-vos que totes les connexions estiguin ajustades per evitar fuites.
- Open the valve on the propane tank slowly.
4.4 Connexió de la bateria
For electric start functionality, ensure the battery is properly connected.
- Localitzeu el compartiment de la bateria.
- Connect the positive (+) battery cable (red) to the positive terminal on the battery.
- Connect the negative (-) battery cable (black) to the negative terminal on the battery.
- Assegureu-vos que les connexions siguin segures.
5. Instruccions de funcionament
Follow these steps for safe and effective operation of your Pulsar GD10KBN generator.
5.1 Arrencada del generador
- Col·locació: Position the generator outdoors in a well-ventilated area, away from any structures, windows, or vents.
- Selecció de combustible:
- If using gasoline, ensure the fuel valve is open.
- If using propane, ensure the propane tank valve is open and the hose is securely connected.
- Asfixia: Moveu la palanca de l'estrangulador a la posició "CHOKE" (arrencada en fred).
- Interruptor del motor: Gireu l'interruptor del motor a la posició "ON".
- Mètode d'inici:
- Arrencada elèctrica: Press and hold the "START" button until the engine starts.
- Inici de retrocés: Estireu la maneta de l'arrencador de retrocés amb fermesa i constantment fins que el motor arrenqui.
- Ajust de l'estrangulador: Un cop el motor s'hagi engegat, moveu lentament la palanca de l'estrangulador a la posició "RUN".
5.2 Connexió de càrregues elèctriques
Once the generator is running stably, you can connect your electrical devices.
- Ensure all appliances are turned off before plugging them into the generator.
- Plug in your devices one at a time, starting with the highest wattage elements.
- Monitor the digital multimeter for voltaglectures d'e i freqüència.
- No supereu la potència nominal de funcionament del generadortage (8,000W on gasoline, 7,200W on propane). Overloading will trip the circuit breakers.

Figure 5.2.1: Visual representation of available outlets (30A AC 120V/240V, 20A AC 120V, 50A AC 120V/240V), approximate run time, engine size, and fuel efficiency.
5.3 Low Idle Control
The generator features a low idle control switch. When activated, the engine RPM will automatically adjust based on the load, conserving fuel and reducing noise. For maximum power output or when starting high-demand appliances, it may be beneficial to turn low idle control off.
5.4 Apagat del generador
- Apagueu i desconnecteu totes les càrregues elèctriques connectades.
- Deixeu que el generador funcioni durant uns minuts sense càrrega perquè es refredi.
- Gireu l'interruptor del motor a la posició "OFF".
- Si feu servir propà, tanqueu la vàlvula del dipòsit de propà.
- If storing for an extended period, refer to the maintenance section for proper storage procedures.
6. Manteniment
Regular maintenance ensures the longevity and reliable performance of your Pulsar GD10KBN generator.
6.1 Canvi d'oli del motor
Perform the first oil change after the initial 5 hours of operation (break-in period), and subsequent changes every 50-100 hours or annually, whichever comes first.
- Assegureu-vos que el motor estigui calent però no calent.
- Col·loqueu una safata de drenatge sota el tap de drenatge de l'oli.
- Traieu el tap de drenatge d'oli i el tap/vareta de nivell d'oli per permetre que l'oli s'escorri completament.
- Reinstall the drain plug and tighten securely.
- Refill with the recommended engine oil to the proper level.
6.2 Air Filter Inspection and Cleaning
Inspect the air filter every 50 hours or every 3 months. Clean or replace as necessary.
- Traieu la coberta del filtre d'aire.
- Traieu l'element del filtre d'escuma.
- Wash the foam element in warm, soapy water, rinse thoroughly, and allow to air dry completely. Lightly oil the foam element with engine oil before reinstalling.
- Substituïu la coberta del filtre d'aire.
6.3 Inspecció de la bugia
Inspect the spark plug every 100 hours or every 6 months. Clean or replace if necessary.
- Traieu la tapa de la bugia.
- Utilitzeu una clau de bugia per treure la bugia.
- Inspect for carbon buildup or wear. Clean with a wire brush or replace with a new spark plug of the recommended type.
- Set the spark plug gap according to specifications in the manual.
- Torneu a instal·lar la bugia i la tapa.
6.4 Emmagatzematge
For extended storage (over 30 days), proper preparation is crucial.
- Gasolina: Add a fuel stabilizer to the gasoline tank and run the engine for a few minutes to circulate the stabilizer. Alternatively, drain all gasoline from the tank and carburetor.
- Propà: Disconnect the propane tank and store it separately.
- Oli: Canviar l'oli del motor.
- Bateria: Disconnect the battery and store it in a cool, dry place, charging it periodically.
- Netegeu l'exterior del generador.
- Emmagatzemar en un lloc net, sec i ben ventilat.
7. Solució De Problemes
Aquesta secció tracta els problemes habituals que podeu trobar amb el vostre generador.
| Problema | Causa possible | Solució |
|---|---|---|
| El motor no arrencarà |
|
|
| Sense potència de sortida |
|
|
| El motor funciona de manera irregular o s'atura |
|
|
8. Especificacions
Detailed technical specifications for the Pulsar GD10KBN generator.
| Característica | Detall |
|---|---|
| Marca | Púlsar |
| Nom del model | Pulsar 10,500w Dual-Fuel Inverter Generator (GD10KBN) |
| Wattage (gasolina) | 10500 watts màxims / 8000 watts de funcionament |
| Wattage (propà) | 9400 watts màxims / 7200 watts de funcionament |
| Tipus de combustible | Gasolina, propà |
| Font d'alimentació | Alimentat per combustible |
| Usos recomanats | Camping, Residencial |
| Pes de l'article | 125 lliures |
| Voltage | 120V / 240V |
| Tipus de motor | 4 Traç |
| Desplaçament del motor | 457 centímetres cúbics |
| Volum del dipòsit | 8 galons |
| Preses de corrent total | 6 |
| Dimensions del producte | 29.9 cm de llargada x 21.5 cm d'amplada x 22.8 cm d'alçada |
| Característiques especials | Automatic Shut Down, Automatic Voltage Regulation, Digital Display, Dual Fuel, Extra-Long Run Time, Fuel Efficient, Fuel Gauge, Hour Meter, Low Oil Shutdown, Overload Protection, Portable, Short Circuit Protection |
8.1 Reference Wattage per a electrodomèstics comuns
The following table provides estimated running and starting wattages for common household appliances. Use this as a guide to manage your generator's load.
| Electrodomèstic | Watts corrents | Començant Watts |
|---|---|---|
| Pantalla LED/LCD | 150 | -- |
| Nevera | 700 | 2200 |
| Microones | 1000 | 3500 |
| Graella elèctrica | 1650 | -- |
| Rentadora | 1150 | 2250 |
| Central AC 3 Ton | 5400 | 7200 |
9. Garantia i Suport
Your Pulsar GD10KBN generator is covered by a Garantia del fabricant de 3 anysSi us plau, conserveu el comprovant de compra per a reclamacions de garantia.
For technical assistance, parts, or warranty inquiries, please contact Pulsar Product customer support. Refer to the contact information provided with your product packaging or visit the official Pulsar weblloc.