SENCOR SWS 4250

Manual d'usuari de l'estació meteorològica SENCOR SWS 4250

Model: SWS 4250

1. Introducció

Thank you for choosing the SENCOR SWS 4250 Weather Station. This device provides accurate indoor and outdoor temperature and humidity readings, along with a weather forecast based on atmospheric pressure changes. It also features a radio-controlled clock, date, and day of the week display. Please read this manual carefully before use to ensure proper operation and to maximize the lifespan of your device.

2. Contingut del paquet

  • SENCOR SWS 4250 Main Unit
  • SWS TH4250 Wireless Outdoor Sensor (1 unit)
  • DC 4.5 V / 150 mA Power Adapter
  • Manual d'usuari (aquest document)

3. Producte acabatview

SENCOR SWS 4250 Weather Station main unit and outdoor sensor

Imatge 1: The SENCOR SWS 4250 Weather Station main unit (left) and the SWS TH4250 wireless outdoor sensor (right). The main unit features a color LCD display showing time, date, day of the week, weather forecast symbols, indoor temperature and humidity, and outdoor temperature and humidity. The outdoor sensor is a compact black unit with a small display showing temperature and channel.

4. Configuració

4.1 Alimentació dels dispositius

  1. Sensor exterior: Open the battery compartment on the SWS TH4250 sensor. Insert 2 x 1.5 V AA batteries (not included), observing the correct polarity (+/-). Close the compartment.
  2. Unitat principal: Insert 3 x 1.5 V AAA batteries (not included) into the battery compartment on the back of the main unit, observing the correct polarity. Alternatively, connect the provided DC 4.5 V / 150 mA power adapter to the main unit and a power outlet. Using the power adapter will ensure continuous backlight for the color LCD display.

4.2 Sincronització inicial

After powering both units, the main unit will automatically attempt to connect with the outdoor sensor. Ensure the sensor is within range (up to 30 meters outdoors). The outdoor temperature and humidity should appear on the main unit's display. If not, refer to the Troubleshooting section.

4.3 DCF77 Radio-Controlled Time

The main unit will automatically attempt to receive the DCF77 radio signal for accurate time and date synchronization. This process may take several minutes or hours depending on your location and environmental conditions. Ensure the unit is placed away from sources of interference. The time can also be set manually if the DCF77 signal is not available or desired.

4.4 Col·locació

  • Unitat principal: Place the main unit indoors on a flat surface (for standing) or mount it on a wall. Choose a location where the display is easily visible and away from direct sunlight or heat sources that could affect indoor temperature readings.
  • Sensor exterior: Mount the outdoor sensor in a sheltered location to protect it from direct rain and sunlight, which can affect accuracy. Ensure it is within the 30-meter transmission range of the main unit and that there are no major obstructions.

5. Instruccions de funcionament

5.1 Mostra finalview

The color LCD display shows the following information:

  • Weather Forecast Symbols: Sunny, slightly cloudy, cloudy, rain.
  • Temps digital: 12/24 hour format selectable.
  • Date and Day of the Week.
  • Indoor Temperature and Humidity.
  • Outdoor Temperature and Humidity.
  • Memòria mín./màx.: Records the minimum and maximum temperature and humidity values.

5.2 Configuració de l'hora i la data

If the DCF77 signal is not received or you wish to set the time manually:

  1. Press and hold the 'SET' button (location typically on the back or side of the unit) to enter time setting mode.
  2. Use the '+' or '-' buttons to adjust the flashing value (e.g., hour, minute, year, month, day).
  3. Press 'SET' again to confirm the setting and move to the next parameter.
  4. Repeat until all settings are complete. The unit will exit setting mode automatically after a period of inactivity or by pressing 'SET' one last time.

5.3 Selecció de la unitat de temperatura

Press the '°C/°F' button (usually on the back or side) to switch between Celsius and Fahrenheit temperature display.

5.4 Min/Max Memory

Premeu el botó 'MEM' per a view the recorded minimum and maximum indoor/outdoor temperature and humidity values. Press 'MEM' again to cycle through min, max, and current readings. To clear the memory, press and hold the 'MEM' button while viewing the min/max values.

5.5 Funció de repetició

If the unit has an alarm function, the 'SNOOZE' button (often combined with the backlight button) will temporarily silence the alarm for a set period.

5.6 Multi-Sensor Support

The SWS 4250 main unit supports up to 3 wireless outdoor sensors. If you have additional SWS TH4250 sensors (sold separately), you can add them by following the pairing instructions in their respective manuals. The main unit will cycle through the connected sensor channels or allow manual selection.

6. Manteniment

  • Neteja: Clean the main unit and sensor with a soft, damp tela. No utilitzeu netejadors abrasius ni dissolvents.
  • Substitució de la bateria: Replace batteries in both the main unit and the outdoor sensor when the low battery indicator appears on the display. Ensure correct polarity.
  • Emmagatzematge: If the device will not be used for an extended period, remove all batteries to prevent leakage.
  • Condicions ambientals: Avoid exposing the main unit to extreme temperatures, direct sunlight, or high humidity. The outdoor sensor is designed for outdoor use but should be protected from direct precipitation.

7. Solució De Problemes

  • No hi ha cap pantalla a la unitat principal:
    - Check if the power adapter is securely connected or if the AAA batteries are inserted correctly and are not depleted.
  • No Outdoor Temperature/Humidity Reading:
    - Ensure the outdoor sensor has fresh AA batteries and is within the 30-meter transmission range of the main unit.
    - Check for obstructions between the main unit and the sensor.
    - Try re-synchronizing the sensor by removing and reinserting its batteries, then pressing the 'CHANNEL' or 'SYNC' button on the main unit (if available).
  • Hora/data incorrecta:
    - Verify that the DCF77 signal reception icon is displayed. If not, try relocating the main unit to an area with better reception.
    - Manually set the time and date as described in section 5.2.
  • Lectures inexactes:
    - Ensure both units are placed away from direct heat sources, cold drafts, or direct sunlight.
    - Allow some time for the readings to stabilize after initial setup or relocation.

8. Especificacions

ModelSWS 4250
Rang de temperatura interiorDe 0 °C a +50 °C (de 32 °F a 122 °F)
Interval de temperatura exterior-20 °C a +60 °C (-4 °F a 140 °F)
Humidity Range (Indoor & Outdoor)20% to 90% rF
Precisió de la temperatura±1 °C
Freqüència de transmissió433 MHz
Rang de transmissióUp to 30 m (outdoor, open area)
Potència de la unitat principal3 x 1.5 V AAA batteries (not included) or DC 4.5 V / 150 mA adapter (included)
Potència del sensor2 piles AA de 1.5 V (no incloses)
Main Unit Dimensions (W x H x D)173 x 125 x 22 mm (6.81 x 4.92 x 0.87 polzades)
Pes de la unitat principal238 g (15.66 unces)
Característica especialLightweight, Color LCD Display, Radio-controlled Time (DCF77)

9. Garantia i Suport

SENCOR products are manufactured to high-quality standards. For information regarding warranty terms and conditions, please refer to the warranty card included with your purchase or visit the official SENCOR website. For technical support or service inquiries, please contact SENCOR customer service through their official channels.

Documents relacionats - SWS 4250

Preview Manual d'usuari de l'estació meteorològica sense fil SENCOR SWS 9300 5 en 1
Aquest manual d'usuari proporciona instruccions completes per a l'estació meteorològica sense fil SENCOR SWS 9300. Cobreix la configuració, el funcionament, funcions com la temperatura interior/exterior, la humitat, la velocitat del vent, la direcció del vent, la pluja, la pressió baromètrica, la previsió meteorològica i les funcions d'alarma. Inclou consells per a la resolució de problemes, precaucions de seguretat i especificacions tècniques.
Preview Manual d'usuari de l'estació meteorològica sense fil Sencor SWS 8700
Manual d'usuari complet per a l'estació meteorològica sense fil Sencor SWS 8700. Aquesta guia cobreix la configuració, el funcionament, funcions com el control de la temperatura i la humitat, la previsió meteorològica, les alarmes, les especificacions i les instruccions d'eliminació.
Preview Manual d'instruccions de l'estació meteorològica Sencor SWS 5600
Manual d'instruccions complet per a l'estació meteorològica Sencor SWS 5600, que cobreix les característiques, la instal·lació, el funcionament i la resolució de problemes.
Preview SENCOR SWS 230 Radio-Controlled Clock User Manual
User manual for the SENCOR SWS 230 radio-controlled clock. This guide provides detailed instructions on installation, setup, automatic and manual signal reception (DCF), time and alarm settings, temperature monitoring (indoor/outdoor max/min), weather forecasting, time zone selection, and troubleshooting. Learn how to care for your device and dispose of it responsibly.
Preview Manual d'usuari de l'estació meteorològica SENCOR SWS 2300
Manual d'usuari complet per a l'estació meteorològica SENCOR SWS 2300, que detalla funcions com el control de la temperatura i la humitat, la previsió meteorològica, les funcions d'alarma i les instruccions de configuració.
Preview Manual d'usuari de l'estació meteorològica WI-FI SENCOR SWS 12500
Guia completa per configurar i utilitzar l'estació meteorològica SENCOR SWS 12500 WI-FI. Aprèn sobre el seu sensor 7 en 1, el sensor termohigro, la previsió meteorològica, la càrrega de dades i el manteniment.