Sper Scientific 860033

Sper Scientific Benchtop Water Quality Meter Model 860033 User Manual

Multi-Parameter pH, ORP, Conductivity, TDS, Salinity & Temperature Analyzer

1. Introducció

The Sper Scientific Benchtop Water Quality Meter Model 860033 is a multi-parameter instrument designed for precise measurement of various water quality indicators. This device accurately measures pH, Oxidation-Reduction Potential (ORP), millivolts (mV), conductivity, Total Dissolved Solids (TDS), salinity, and temperature. It is suitable for a wide range of applications in laboratories and industrial environments, offering features such as automatic calibration and temperature compensation.

Sper Scientific Benchtop Water Quality Meter 860033 displaying pH reading

Figure 1: Sper Scientific Benchtop Water Quality Meter Model 860033 in operation, measuring pH in a beaker.

2. Configuració

2.1 Desembalatge i components

Desembaleu amb cura tots els components i verifiqueu que hi hagi els elements següents:

  • Sper Scientific Benchtop Water Quality Meter 860033
  • Conductivity Electrode (also measures TDS and Salinity)
  • pH Electrode (also measures mV)
  • Multiple Electrodes Holder Arm
  • Adaptador de CA
  • Cable de l’ordinador
  • Programari CD
All components of the Sper Scientific Benchtop Water Quality Meter 860033

Figure 2: All included components of the Benchtop Water Quality Meter, including the main unit, electrodes, power adapter, and accessories.

2.2 Connecting Electrodes and Power

  1. Attach the Electrode Holder Arm: Securely attach the multiple electrodes holder arm to the side of the meter unit.
  2. Connectar els elèctrodes: Connect the pH electrode to the BNC connector on the rear panel. Connect the conductivity electrode to its designated port.
  3. Connect AC Adaptor: Plug the AC adaptor into the DC input port on the rear of the meter, then connect it to a standard power outlet. The meter operates on AC voltage and does not use batteries.
  4. Optional PC Connection: For data logging and analysis, connect the computer cable to the RS232 port on the meter and to your computer. Install the provided software.
Rear panel connections of the Sper Scientific Benchtop Water Quality Meter 860033

Figure 3: Rear panel of the meter showing DC power input, RS232 port, analog outputs, and BNC/ATC connections for electrodes.

3. Instruccions de funcionament

3.1 Encès/Apagat

Premeu el botó PODER button to turn the meter on. The large LCD will display the current parameter, time, date, and temperature. Press the PODER button again to turn the meter off.

3.2 Selecció de paràmetres

Utilitza el MODE button to cycle through the available measurement parameters: pH, ORP, mV, Conductivity, TDS, Salinity, and Temperature.

3.3 Calibració

The meter features automatic buffer recognition for pH calibration and supports 5 calibration points. Refer to the detailed calibration procedure in the full instruction manual for each specific parameter (pH, ORP, Conductivity, TDS, Salinity).

  • Calibració del pH: Use standard pH buffer solutions. The meter will automatically recognize the buffer values.
  • Conductivity/TDS/Salinity Calibration: Use appropriate standard solutions.

3.4 Prendre mesures

  1. Ensure the appropriate electrode is connected and properly conditioned.
  2. Seleccioneu el paràmetre de mesura desitjat mitjançant el botó MODE botó.
  3. Immerse the electrode(s) into the sample solution. Ensure the sensor part of the electrode is fully submerged.
  4. Allow the reading to stabilize. The meter provides automatic or manual temperature compensation and ranging.
  5. The LCD will display the stable measurement.
  6. Utilitza el HOLD/REC button to hold the current reading or record data (if connected to PC with software).

4. Manteniment

4.1 Cura dels elèctrodes

  • Elèctrode de pH: Always keep the pH electrode bulb moist. Store it in a suitable storage solution or pH 4 buffer when not in use. Never store in distilled water.
  • Conductivity Electrode: Rinse the conductivity electrode with distilled water after each use. Store dry or in a conductivity storage solution as recommended.
  • Neteja: Clean electrodes regularly according to the full manual's instructions to prevent buildup that can affect accuracy.

4.2 Meter Cleaning

Wipe the meter's housing with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the meter's ports or openings.

4.3 Emmagatzematge

When not in use for extended periods, disconnect the AC adaptor and store the meter and electrodes in a clean, dry environment within the specified operating temperature range.

5. Solució De Problemes

This section addresses common issues you might encounter with your Sper Scientific Benchtop Water Quality Meter 860033.

  • Lectures inestables: If readings are unstable, ensure electrodes are properly conditioned and calibrated. Gently stir the sample solution around the probe to help readings settle. Check for air bubbles on the electrode surface.
  • Lectures inexactes: Recalibrate the meter with fresh standard solutions. Check electrodes for damage or contamination. Ensure temperature compensation is correctly applied.
  • Meter Not Powering On: Verify the AC adaptor is securely connected to both the meter and a working power outlet.
  • No Communication with PC: Ensure the computer cable is correctly connected and the software drivers are installed. Check the RS232 port settings on your computer.

For more detailed troubleshooting steps, please refer to the comprehensive instruction manual provided with your device or contact Sper Scientific customer support.

6. Especificacions

The following table outlines the measurement ranges, resolutions, and accuracies for the Sper Scientific Benchtop Water Quality Meter Model 860033.

Table of specifications for Sper Scientific Benchtop Water Quality Meter 860033

Figure 4: Detailed specifications including measurement ranges, resolutions, and accuracies for pH, mV/ORP, Conductivity, TDS, Salinity, and Temperature.

Especificacions generals
CaracterísticaDetall
Dimensions8.5 polzades (L) x 6.5 polzades (W) x 2.25 polzades (H)
Font d'alimentacióAC Adaptor (no batteries required)
SortidesDigital (RS232), Analog
Compensació de temperaturaAutomàtic o Manual
Reconeixement del tampó de pHAutomàtic
Punts de calibració5
CertificacionsAprovat CE

7. Informació de la garantia

Sper Scientific products are manufactured under strict quality control standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Sper Scientific weblloc web. Conserveu el rebut de compra com a comprovant de compra per a qualsevol reclamació de garantia.

8. Atenció al client

If you require technical assistance, have questions about your meter, or need to order replacement parts, please contact Sper Scientific customer support. Contact information can typically be found on the product packaging, the official website, or the full instruction manual.

Sper Scientific Contact Information:

  • Weblloc: www.sperscientific.com (for product information, FAQs, and support resources)
  • Correu electrònic/Telèfon: Consulteu el website or product documentation for the most current contact details.

Documents relacionats - 860033

Preview Manual d'operació de l'analitzador d'oxigen dissolt portàtil
Aquest manual d'instruccions proporciona instruccions detallades per a l'analitzador portàtil d'oxigen dissolt, que cobreix informació sobre configuració, calibratge, funcionament, manteniment i seguretat per a un control precís de la qualitat de l'aigua.
Preview Manual d'usuari i especificacions del bolígraf d'oxigen dissolt Sper Scientific 850045
Manual d'usuari i especificacions del bolígraf d'oxigen dissolt Sper Scientific 850045. Aprèn sobre les seves característiques, com calibrar i mesurar l'oxigen dissolt i la temperatura, el manteniment de la sonda, la substitució de la bateria, les especificacions tècniques i la informació de garantia.
Preview Sper Scientific 850031 Datalogging UVAB/UVC Meter Instruction Manual
Instruction manual for the Sper Scientific Model 850031 Datalogging UVAB/UVC Meter, detailing its features, measurement procedures for UVA, UVC, and temperature, datalogging functions, advanced settings, specifications, and warranty. Designed for industrial, scientific, and safety applications.
Preview Manual d'instruccions del refractòmetre digital Sper Scientific
Manual d'instruccions per als refractòmetres digitals Sper Scientific (models 300033, 300034, 300035, 300036), que cobreix el funcionament, el calibratge, les especificacions i la garantia.
Preview Manual d'operació del detector de qualitat de l'aire Sper Scientific
Aquest manual proporciona instruccions per al funcionament del detector de qualitat de l'aire Sper Scientific, incloent-hi la configuració, la configuració del sistema, els registres històrics, la correcció del sensor, la modificació de dades i els avisos d'alarma.
Preview Termòmetre d'infrarojos de doble ús sense contacte Sper Scientific TE-94: mesura de temperatura de precisió
Descobreix el termòmetre d'infrarojos de doble ús sense contacte i certificat NIST Sper Scientific TE-94. Ofereix precisió, comoditat i mesurament avançat sense contacte de la temperatura corporal i superficial. Ideal per a ús domèstic, d'oficina i industrial.