PowMr POW-RELAB-5KU

Manual d'usuari de l'inversor solar PowMr de 5000 W

Model: POW-RELAB-5KU

1. Introducció

This manual provides essential instructions for the installation, operation, and maintenance of your PowMr 5000W Off-Grid Hybrid Solar Inverter. Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage to the unit or injury to personnel. Keep this manual for future reference.

2. Instruccions de seguretat

WARNING: This section contains important safety instructions that must be followed during installation and operation of the inverter. Failure to follow these instructions may result in severe injury or death.

3. Producte acabatview

3.1 Característiques

3.2 Identificació de components

The PowMr 5000W Solar Inverter features a robust design with clearly labeled connection points and an intuitive display panel.

PowMr 5000W Solar Inverter Front View

Imatge 1: Frontal view of the PowMr 5000W Solar Inverter. This image displays the main unit, highlighting its compact form factor and the location of the LCD display and control buttons on the front panel. The cooling fins are visible on the sides, indicating its heat dissipation design.

4. Configuració

4.1 Selecció del lloc

4.2 Muntatge de l'inversor

  1. Mark the positions for the mounting screws on the wall.
  2. Perforeu forats i inseriu ancoratges de paret si cal.
  3. Securely mount the inverter to the wall using appropriate screws.

4.3 Connexions de cablejat

IMPORTANT: All wiring must comply with local and national electrical codes. Ensure all connections are tight and secure.

  1. Connexió de la bateria: Connect the 48V battery bank to the inverter's battery terminals. Ensure correct polarity (positive to positive, negative to negative). Use appropriate cable gauges and fuses/breakers.
  2. Connexió del panell fotovoltaic: Connect the solar panel array to the PV input terminals. Verify that the PV array's open circuit voltage (Voc) does not exceed 150Vdc and the MPPT voltage range is 60~150Vdc. Ensure correct polarity.
  3. Connexió d'entrada de CA: Connect the utility grid or generator AC power to the AC input terminals. Install an external circuit breaker for protection.
  4. Connexió de sortida de CA: Connect your AC loads to the AC output terminals. Install an external circuit breaker for protection.
  5. Posada a terra: Connect the inverter's ground terminal to a reliable earth ground.

5. Funcionament

5.1 Inici inicial

  1. After all connections are made and verified, switch on the battery breaker.
  2. Switch on the PV array breaker.
  3. Switch on the AC input breaker (if connected).
  4. Press and hold the power button on the inverter for a few seconds to turn it on.
  5. The LCD display will illuminate, and the inverter will begin its self-test sequence.

5.2 Pantalla LCD i indicadors

The LCD display provides real-time system data such as input/output voltage, current, frequency, battery status, and operating mode. The three LED indicators show:

Use the function buttons to navigate through the display menus and configure settings such as charging modes and output modes.

5.3 Modes de funcionament

The inverter supports various operating modes to optimize power usage:

5.4 Procediment d'aturada

  1. Turn off all AC loads connected to the inverter.
  2. Press and hold the power button on the inverter to turn it off.
  3. Switch off the AC input breaker.
  4. Switch off the PV array breaker.
  5. Switch off the battery breaker.

6. Manteniment

6.1 Comprovacions periòdiques

6.2 Neteja

6.3 Manteniment de la bateria

Refer to your battery manufacturer's guidelines for specific maintenance procedures. Ensure battery terminals are clean and free of corrosion. For lead-acid batteries, check electrolyte levels periodically if applicable.

7. Solució De Problemes

If the inverter is not operating correctly, refer to the following common issues and solutions. For persistent problems, contact technical support.

ProblemaCausa possibleSolució
L'inversor no s'encénNo hi ha connexió de bateria o el volum de la bateria és baixtageComproveu les connexions de la bateria i el voltage. Charge battery if low.
Sense sortida de CAOverload, short circuit, or fault conditionReduce load, check for short circuits, refer to LCD fault code.
La bateria no es carregaPV array disconnected, low PV voltage, or charger faultCheck PV connections, ensure sufficient sunlight, verify PV voltage.
LED d'error il·luminatInternal fault or protection triggeredNote the fault code on the LCD display and consult the specific fault code section in the full manual (if available) or contact support.

8. Especificacions

ParàmetreValor
Potència de sortida nominal5000W
Potència màxima15000W
Vol. De sortida nominaltage Rang110 Vca ± 10%
Volum d’entrada nominal CCtage48Vdc
Màx. Potència de matriu fotovoltaica6400W
Vol d'entrada MPPTtage Rang60~150Vdc
Màx. Circuit obert de matriu fotovoltaica Voltage150Vdc
Corrent de càrrega màxima de CA29A
Màx. Corrent de càrrega fotovoltaica120A
Eficiència>98%
Dimensions del producte (L x A x A)15 x 7 x 20 polzades
Pes de l'article59.4 lliures
Número de modelPOW-RELAB-5KU
FabricantPow Sr

9. Garantia i Suport

This PowMr inverter comes with a manufacturer's warranty. Please refer to the warranty card included with your product for detailed terms and conditions, including warranty period and coverage.

For technical support, troubleshooting assistance, or warranty claims, please contact PowMr customer service through the retailer where the product was purchased or visit the official PowMr weblloc per obtenir informació de contacte.