1. Introducció
The Lansinoh Thrive 2-in-1 Breast Pump (Model P3) offers versatile pumping solutions, combining the convenience of a wearable pump with the power of a hospital-strength electric pump. This manual provides essential information for safe and effective use, assembly, operation, and maintenance of your breast pump.

The Lansinoh Thrive 2-in-1 Breast Pump offers both wearable and traditional pumping options for flexibility.
2. Què hi ha a la caixa
Your Lansinoh Thrive 2-in-1 Breast Pump package includes the following components:
- 1x Thrive Pump Hub (Motor)
- 2x High Capacity 6oz Wearable Cups (24mm flange size)
- 2x SoftSeal Flanges (24mm) for traditional pumping
- 2x Wide Neck Bottles
- 2x Flange Inserts (21mm)
- 1x NaturalWave Nipple
- 2x Storage Lids
- 1x Tubing Set
- 2x Bra Extension Straps
- 1x cable de càrrega
- Manual d'instruccions

All components included in the Lansinoh Thrive 2-in-1 Breast Pump package.
Vídeo d'unboxing
Watch this video for a detailed unboxing of the Lansinoh Thrive 2-in-1 Breast Pump.
3. Muntatge i instal·lació
Before first use, sterilize all pump parts that come into contact with breast milk. Ensure all parts are completely dry before assembly.
Assembling the Wearable Cups:
- Attach the valve to the silicone diaphragm, ensuring it is horizontal.
- Insert the diaphragm into the collection cup, pressing it firmly to ensure it is lined up and sealed.
- Attach the spout facing outward.
- Line up the top of the flange with the spout for easy pouring.
- Reattach the flange and press around the sides to seal.
- Optionally, add an internal flange insert (21mm) for personal preference and fit.
- Attach the tubing to the collection cup and the pump hub.
Assembling the Traditional Pump Kit:
- Attach the valve to the breast flange.
- Screw the breast flange onto a Lansinoh Wide Neck Bottle.
- Attach the diaphragm cap to the top of the breast flange.
- Attach the tubing to the diaphragm cap and the pump hub.

The pump can be configured for double or single pumping with either wearable cups or traditional flanges.
Vídeo de muntatge
Detailed video guide on how to assemble the Lansinoh Thrive 2-in-1 Breast Pump.
4. Funcionament
The Thrive Pump Hub features an easy-to-read LCD display and intuitive controls for a personalized pumping experience.

The control panel allows for easy adjustment of settings.
Pumping Modes:
- Mode d'estimulació: Mimics a baby's rapid suckling to initiate milk flow.
- Mode d'expressió: Slower, deeper suction to efficiently express milk once flow has started.
You can switch between these modes and adjust the suction level (9 levels) and speed settings (high/low) to find what is most comfortable and effective for you. The pump also features a timer and remembers your previous settings.
Using the Wearable Cups:
The wearable cups offer hands-free mobility, allowing you to pump discreetly while multitasking. Ensure the cups are securely placed in your bra for optimal suction and comfort.

Enjoy hands-free pumping with the wearable cups, perfect for multitasking.
Using the Traditional Setup:
The traditional setup provides hospital-grade suction for maximum milk output. This is ideal for dedicated pumping sessions.

The traditional setup offers powerful, hospital-grade suction for efficient milk expression.
Vídeos d'operacions
First impressions and overview of the Lansinoh Thrive 2-in-1 Breast Pump's operation.
Demonstration of using the wearable pump while working from home.
5. Neteja i Manteniment
Proper cleaning and maintenance are crucial for hygiene and pump longevity. Always clean pump parts immediately after each use.
Instruccions de neteja:
- Disassemble all parts that come into contact with breast milk.
- Wash all disassembled parts in warm, soapy water. Use a soft brush for thorough cleaning.
- Rinse thoroughly under clear running water.
- Air dry on a clean surface or use a dedicated drying rack. Avoid using cloth towels as they may leave lint.
- Sterilize parts regularly according to manufacturer guidelines (e.g., boiling, steam sterilizer, or dishwasher top rack).
- Wipe the pump hub with a clean, damp cloth. Do not immerse the hub in water.
Store all clean and dry parts in a clean, covered container until next use.

Proper milk handling and storage are essential after pumping.
6. Solució De Problemes
If you encounter issues with your Lansinoh Thrive 2-in-1 Breast Pump, please refer to the following common solutions:
- Succió baixa: Check that all pump parts are correctly assembled and sealed. Ensure tubing is free from kinks or damage. Verify the diaphragm is properly seated.
- Sense energia: Ensure the pump hub is fully charged. Check the charging cable connection.
- Discomfort During Pumping: Adjust suction levels and speed settings. Ensure you are using the correct flange size (24mm or 21mm insert). Consult the flange sizing guide if unsure.
- Low Milk Output: Ensure proper flange fit. Try different pumping modes and settings. Consider increasing pumping frequency or duration.
- Milk Leakage: Verify all parts are correctly assembled and sealed, especially the wearable cups. Ensure the collection cups are not overfilled.
For further assistance, please contact Lansinoh customer support.
7. Especificacions
| Característica | Detall |
|---|---|
| Dimensions del producte | 9.3 x 7.6 x 8.6 polzades |
| Pes | 2.6 lliures |
| Número de model | Model S1DW/Model P3 |
| Bateries | 1 bateria de ions de liti (inclosa) |
| Força de succió | Up to 280mmHG (Hospital-grade) |
| Pumping Modes | 2 (Stimulation, Expression) |
| Nivells d'aspiració | 9 nivells ajustables |
| Configuració de velocitat | Adjustable (High, Low) |
| Nivell de soroll | <45dB (Whisper-quiet) |
| Tipus de material | Silicona |
| Color | Blanc |
8. Informació de seguretat
Please read and understand all safety warnings and instructions before using this product. Failure to do so may result in injury or product damage.
- This breast pump is intended for personal use by lactating women to express breast milk.
- No utilitzeu aquest dispositiu per a un altre propòsit que no sigui el previst.
- Keep the pump hub and electrical components away from water and moisture.
- Always inspect pump parts for wear or damage before each use. Replace damaged parts immediately.
- Mantenir fora de l'abast dels nens. Les peces petites poden suposar un perill d'asfíxia.
- No utilitzar-lo mentre es banya o es dutxa.
- Consult a healthcare professional if you experience pain or discomfort during pumping.
9. Garantia i assistència
Lansinoh products are designed with quality and reliability in mind. For warranty information, product registration, or customer support, please visit the official Lansinoh weblloc web o poseu-vos en contacte amb el seu departament d'atenció al client. Conserveu el comprovant de compra per a reclamacions de garantia.