1. Introducció
Thank you for choosing the NJTY Voltage Tester & Digital Multimeter Bundle. This comprehensive kit provides essential tools for electrical testing, suitable for both DIY projects and professional applications. This manual provides detailed instructions for the safe and effective use of both the Digital Multimeter and the Non-Contact Voltage Tester.
2. Producte acabatview
This bundle includes two primary devices:
- NJTY T3 Digital Multimeter: A compact device with a vibrant color screen for precise measurements of AC/DC voltage, continuïtat, resistència i més.
- NJTY Non-Contact VoltagProvador: A pen-style tester with voice alerts for identifying live and neutral wires, featuring non-contact voltage detection and breakpoint testing.

Figure 2.1: The NJTY Voltage Tester and Digital Multimeter Bundle.
3. Configuració
3.1. NJTY T3 Digital Multimeter Setup
The NJTY T3 Digital Multimeter features a built-in rechargeable battery. Before first use, ensure the device is fully charged.
- Càrrega: Connect the multimeter to a standard USB power source using the provided Type-C USB cable. The charging indicator will illuminate.
- Cables de prova: Insert the red test lead into the 'VΩmA' input jack and the black test lead into the 'COM' input jack. Ensure a secure connection.

Figure 3.1: The NJTY T3 Digital Multimeter connected for Type-C charging.
3.2. NJTY Non-Contact Voltage Tester Setup
El volum sense contactetage Tester is typically powered by internal batteries. Ensure they are properly installed or charged if rechargeable.
- Encès: Press the power button to turn on the device. A self-test may occur.
4. Instruccions de funcionament
4.1. NJTY T3 Digital Multimeter Operation
The multimeter features an auto-function scan for ease of use.
- Encès/apagat: Press and hold the power button to turn the multimeter on or off.
- Escaneig automàtic de funcions: The multimeter automatically detects the type of measurement (AC/DC voltage, resistance, continuity) when the test leads are connected to a circuit.
- Mesurament AC/DC Voltage: Connect the test leads across the circuit or component to measure voltage. The display will show the reading.
- Prova de continuïtat: In continuity mode, the multimeter will emit an audible beep if the resistance between the two test points is below approximately 50Ω, indicating a continuous circuit.
- Mesura de la resistència: Connecteu els cables de prova a través del component per mesurar-ne la resistència.
- NCV (vol sense contacte).tage) Detecció: Move the top of the multimeter near an AC voltage source. The device will indicate the presence of voltagi sense contacte directe.
- Conservació de dades: Premeu el botó «HOLD» per congelar la lectura actual a la pantalla. Torneu a prémer-lo per alliberar-lo.
- Flashlight/Backlight: The multimeter includes a built-in flashlight and backlight for improved visibility in dark environments.

Figure 4.1: Key features and display of the NJTY T3 Digital Multimeter.

Figura 4.2: Volum sense contactetage (NCV) detection with the Digital Multimeter.

Figure 4.3: The flashlight function of the Digital Multimeter for dark environments.
4.2. NJTY Non-Contact Voltage Tester Operation
El voltage tester is designed for quick and safe voltage detecció.
- NCV (vol sense contacte).tage) Detecció: Place the tip of the tester near a wire or outlet. The device will indicate the presence of AC voltage mitjançant alertes visuals i audibles.
- Ajust de sensibilitat: The tester offers dual sensitivity ranges (12-1000V and 48-1000V). Use the sensitivity button to switch between low and high sensitivity modes as needed for different applications.
- Live/Neutral Wire Identification: The tester uses voice alerts to audibly distinguish between live (hot) and neutral wires, enhancing safety and ease of identification.
- Break-Point Test: Use the tester to identify breaks in wires or cables. Move the tester along the wire; the absence of a signal indicates a break.
- Flashlight & Laser: The tester includes a built-in flashlight for illuminating work areas and a laser for precise alignment or pointing.

Figure 4.4: Sensitivity adjustment feature of the Voltage Tester.

Figure 4.5: The Voltage Tester's voice alert system for identifying live wires.

Figure 4.6: Using the Voltage Tester for break-point detection in wires.

Figure 4.7: The Voltage Tester's integrated flashlight and laser for enhanced utility.
5. Manteniment
- Neteja: Wipe the devices with a dry, clean cloth. Do not use abrasive cleaners or solvents.
- Emmagatzematge: Store the bundle in a cool, dry place, away from direct sunlight and extreme temperatures.
- Battery Care (Multimeter): Recharge the multimeter regularly, especially if it will not be used for an extended period, to maintain battery health.
6. Solució De Problemes
- El dispositiu no s'encén: Ensure the battery is charged (Multimeter) or properly installed (Voltage Tester).
- Inaccurate Readings (Multimeter): Check test lead connections. Ensure the correct measurement mode is selected (though auto-scan helps).
- No Detection (Voltage Tester): Ensure the device is powered on. Adjust sensitivity if necessary.
- Funcionament intermitent: Check for loose connections or low battery.
7. Especificacions
7.1. NJTY T3 Digital Multimeter
| Paràmetre | Valor |
|---|---|
| Mostra els recomptes | 4000 recomptes |
| Vol. ACtage Rang | 0.8 V - 600 V |
| DC Voltage Rang | 1.0 V - 600 V |
| Interval de resistència | 0 - 40MΩ |
| Continuity Threshold | <50Ω |
| Font d'alimentació | Rechargeable (Type-C) |
7.2. NJTY Non-Contact Voltage Tester
| Paràmetre | Valor |
|---|---|
| Vol. ACtage Range (Low Sensitivity) | 12 V - 1000 V |
| Vol. ACtage Range (High Sensitivity) | 48 V - 1000 V |
| Interval de freqüència | 50/60Hz |
| Classificació de seguretat | EN61010-1/1000V CAT III |
8. Informació de seguretat
WARNING: Always exercise extreme caution when working with electricity. Failure to follow safety guidelines can result in serious injury or death.
- Always test on a known live circuit before use to ensure the device is functioning correctly.
- Do not use the devices if they appear damaged or are not operating properly.
- Do not exceed the maximum input values specified for each device.
- Utilitzeu equips de protecció individual (EPI) adequats, com ara guants aïllants i ulleres de seguretat.
- Do not attempt to repair or modify the devices. Refer all servicing to qualified personnel.
- Mantenir fora de l'abast dels nens.
9. Garantia i Suport
NJTY products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official NJTY weblloc web. Si us plau, conserveu el comprovant de compra per a reclamacions de garantia.