1. Introducció

This manual provides essential information for the safe and efficient operation of your SUNGOLDPOWER SPH10K48SP-P 10000W 48V Solar Inverter. Please read all instructions and warnings carefully before installation and use. Retain this manual for future reference.

Precaucions de seguretat:

  • Ensure all electrical connections are made by qualified personnel.
  • Desconnecteu sempre l'alimentació abans de realitzar qualsevol manteniment o servei.
  • The inverter is heavy; use proper lifting techniques or assistance during installation.
  • Install in a well-ventilated area to prevent overheating.

2. Contingut del paquet

Verifiqueu que tots els elements que s'enumeren a continuació s'inclouen al vostre paquet:

  • SUNGOLDPOWER SPH10K48SP-P 10000W 48V Solar Inverter
  • Mòdul WiFi
  • WiFi monitoring components
  • Manual d'usuari
  • Targeta de garantia
  • Parallel COM cable
  • Cable de comunicació
  • Cable lugs & Screws
SUNGOLDPOWER SPH10K48SP-P Inverter and Accessories
Figure 2.1: SUNGOLDPOWER SPH10K48SP-P Inverter and included accessories, including the WiFi module, cables, and mounting hardware.

3. Producte acabatview

The SUNGOLDPOWER SPH10K48SP-P is an all-in-one solar charge inverter designed for robust off-grid and hybrid solar systems. It integrates a 10000W pure sine wave inverter, two MPPT solar controllers, and a 200A battery charger, offering flexible AC input/output options (120V/240V settable).

Davant view of the SUNGOLDPOWER SPH10K48SP-P 10000W 48V Solar Inverter
Figura 3.1: Frontal view of the SUNGOLDPOWER SPH10K48SP-P 10000W 48V Solar Inverter, showcasing és blau casing and integrated LCD display.

Característiques principals:

  • Disseny tot en un: Combines inverter, MPPT solar controllers, and battery charger.
  • Sortida d'alta potència: 10000W rated power, 20000W peak power.
  • Dual MPPT Solar Controllers: Max 200A battery charging, 500VDC open circuit voltage.
  • Flexible AC Output: Settable 120V/240V split phase or 120V single phase.
  • Sortida d'ona sinusoïdal pura: Garanteix la compatibilitat amb electrònica sensible.
  • Mòdul WiFi: Allows remote monitoring and parameter adjustment via mobile app.
  • Comunicació BMS: Supports various battery types including Lithium with CAN, USB, and RS485.
  • Múltiples modes de funcionament: Four charging and four output modes for diverse energy management.
  • Time-Slot Function: Optimizes charging/discharging based on tariff rates.
  • Certificació UL1741: Garanteix la seguretat i la fiabilitat.
Key features of the SUNGOLDPOWER 10KW Pure Sine Wave Inverter
Figure 3.2: Visual representation of the inverter's key specifications, including 11000W Max PV Array Power, 500V Max Open Circuit Voltage, and 200A Max Charge Current.
LCD HD Display of the SUNGOLDPOWER Inverter
Figure 3.3: The inverter's LCD HD display, showing real-time data and options for setting various parameters.

4. Configuració

4.1 Instal·lació física

The inverter should be mounted securely in a location that is dry, well-ventilated, and protected from direct sunlight and extreme temperatures. Due to its weight (54 lbs), ensure the mounting surface can support the load. Consider accessibility for future adjustments and maintenance.

4.2 Connexions elèctriques

All electrical wiring must comply with local and national electrical codes. Use appropriate wire gauges for all connections to ensure safety and optimal performance.

4.2.1 Battery Connections

Connect the battery cables to the inverter's battery terminals. Ensure correct polarity: positive (+) to positive and negative (-) to negative. Tighten all connections securely to prevent loose contacts and potential hazards.

System Connection Diagram for SUNGOLDPOWER Inverter
Figure 4.1: A comprehensive system connection diagram illustrating how PV panels, generator, mains, external battery packs, and home appliances connect to the SUNGOLDPOWER inverter in both split-phase and single-phase modes.

4.2.2 PV Input Connections

Connect your solar PV array to the designated PV input terminals on the inverter. Observe correct polarity and ensure the open circuit voltage of the PV array does not exceed 500VDC.

4.2.3 AC Input/Output Connections

Connect the AC input from your utility grid or generator, and the AC output to your loads. The inverter supports both 120V/240V split-phase and 120V single-phase configurations. Refer to the wiring diagram for specific connections.

4.3 Engegada i configuració inicials

After all physical and electrical connections are made, proceed with the initial power-up. The inverter's LCD display allows for configuration of various settings, including battery type, charging modes, and output priorities.

Installation and Wiring Overview

Video 4.1: This video demonstrates the unboxing and initial wiring process for the SUNGOLDPOWER inverter, including connecting battery wires and grounding. It highlights the importance of secure connections and proper placement.

Battery and Inverter Communication Setup

Video 4.2: This video provides a detailed guide on connecting the battery pack to the inverter and configuring communication settings. It covers positive and negative terminal connections, RS485/CAN communication, and initial startup procedures, including setting DIP switches and verifying voltage.

5. Modes de funcionament

The SPH10K48SP-P inverter offers versatile operating modes to optimize energy usage based on your specific needs:

5.1 modes de càrrega:

  • Càrrega híbrida: Utilizes both solar and utility power for battery charging.
  • Utility Priority Charging: Prioritizes utility power for charging, with solar as a supplement.
  • Solar Priority Charging: Prioritizes solar power for charging, with utility as a backup.
  • Només càrrega solar: Carrega bateries exclusivament amb energia solar.

5.2 Output Modes:

  • Prioritat d'utilitat: Loads are primarily powered by the utility grid.
  • Solar and Utility Hybrid: Dynamically uses solar and utility to power loads.
  • Prioritat solar: Loads are primarily powered by solar, then batteries, then utility.
  • Prioritat de l'inversor: Loads are primarily powered by the inverter (from batteries/solar), then utility.
Diagram illustrating the four AC output modes and four battery charging modes of the SUNGOLDPOWER inverter
Figure 5.1: Visual guide to the various working modes, detailing how power flows from utility, solar, and battery to loads under different priority settings.

6. Time-Slot Charging/Discharging Function

The inverter features a time-slot function, allowing users to configure specific charging and discharging periods. This is particularly useful for optimizing energy usage based on local peak and off-peak electricity tariffs, maximizing savings and efficient use of PV energy.

  • Time-slot Utility Charging/Carrying: Set up to three definable periods for utility charging. If PV energy is unavailable or insufficient, utility energy will be used as a supplement.
  • Time-slot Battery Discharging: Set up to three definable periods for battery discharging. During these periods, the inverter prioritizes battery power for loads, switching to mains power if battery power is insufficient.
Diagram explaining the time-slot charging and discharging functions of the SUNGOLDPOWER inverter
Figure 6.1: Illustration of the time-slot charging and discharging feature, showing how users can set periods to utilize mains and battery power according to peak and valley tariffs.

7. Compatibilitat de la bateria

The SPH10K48SP-P inverter is compatible with a wide range of 48V battery types, including:

  • AGM/Sealed
  • Gel
  • Inundat
  • Liti (LiFePO4)
  • User-defined (for custom battery parameters)

It also supports battery-free operation. For lithium batteries, the mains power and photovoltaics can activate a dormant battery. The inverter supports CAN, USB, and RS485 communication with SUNGOLDPOWER batteries for enhanced management.

SUNGOLDPOWER Inverter compatibility with various battery types
Figure 7.1: Diagram showing the inverter's compatibility with different battery chemistries, including Flooded, AGM, GEL, Sealed Lead Acid, LiFePO4, and user-defined settings.

8. Parallel Function

For increased power output or to create a three-phase system, the SPH10K48SP-P inverter supports parallel connection of up to 6 units. This allows for scalable power solutions to meet diverse energy demands.

Wiring diagrams for split-phase and three-phase parallel connections of SUNGOLDPOWER inverters
Figure 8.1: Detailed wiring diagrams for connecting multiple inverters in parallel for both split-phase (two units) and three-phase (three or more units) configurations.

9. Communication & Monitoring

The integrated WiFi module allows users to monitor the inverter's operating status and parameters remotely via a mobile application. BMS communication (CAN, USB, RS485) ensures seamless integration and optimized performance with compatible battery systems.

SUNGOLDPOWER Inverter with WiFi monitoring capabilities
Figure 9.1: The inverter connected to a WiFi module, illustrating remote monitoring of solar, battery, and home energy usage via a smartphone application.

10. Manteniment

Regular maintenance ensures the longevity and optimal performance of your inverter. Perform the following checks periodically:

  • Inspecció visual: Check for any visible damage, loose connections, or signs of overheating.
  • Neteja: Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow. Use a dry cloth for cleaning.
  • Comprovacions de connexió: Periodically verify that all electrical connections (battery, PV, AC) are tight and secure.
  • Medi ambient: Assegureu-vos que l'entorn d'instal·lació es mantingui dins dels rangs de temperatura i humitat especificats.

11. Solució De Problemes

If the inverter displays an error code or exhibits unusual behavior, consult the user manual for specific troubleshooting steps. Common issues and general solutions include:

  • Sense energia: Check all circuit breakers, battery connections, and input power sources.
  • Baixa potència de sortida: Verify PV array performance, battery state of charge, and load requirements.
  • Avís de sobrecàrrega: Reduce connected loads. Ensure total load does not exceed the inverter's rated capacity.
  • Error de comunicació: Check communication cables and settings for BMS or WiFi modules.

For persistent issues, contact SUNGOLDPOWER customer support.

12. Especificacions

Detailed technical specifications for the SUNGOLDPOWER SPH10K48SP-P 10000W 48V Solar Inverter:

CaracterísticaEspecificació
Nom del model10KW 48V Split Phase Solar Inverter
Potència de sortida nominal10,000W
Màx. Potència màxima20,000W
Vol. De sortida nominaltage120/240Vac (split phase/single phase)
Capacitat de càrrega dels motors6 CV
Freqüència nominal AC50/60Hz
Capacitat paral·lela6 unitats
Tipus de bateriaLi-ió / Plom-Àcid / Definit per l'usuari
Volum de bateria nominaltage48Vdc
Voltage Rang40Vdc
Màx. Corrent de càrrega MPPT200A
Corrent de càrrega màxim de la xarxa/generador120A
Corrent de càrrega híbrida màxim200A
Nombre de seguidors MPPT2
Màx. Potència de matriu fotovoltaica11,000W
Màx. Corrent d'entrada22/22A
Màx. Voltage de Circuit Obert500Vdc
MPPT Voltage Rang125Vdc
Bypass corrent de sobrecàrrega63A
Eficiència de seguiment MPPT99.9%
Support CommunicationWiFi Modules/RS485 /CAN/USB/Dry contact
Dimensions del producte26 x 17.9 x 4.9 polzades
Pes de l'article54 lliures
Table of specifications for SUNGOLDPOWER SPH8048P and SPH10048P inverters
Figure 12.1: A comparative table of specifications for the SPH8048P and SPH10048P models, detailing power, voltage, current, and communication features.

13. Garantia i assistència

SUNGOLDPOWER products are backed by a manufacturer's warranty. Please refer to the included Warranty Card for detailed terms and conditions. For technical assistance, troubleshooting, or warranty claims, please contact SUNGOLDPOWER customer support through their official channels.

Documents relacionats - SPH10K48SP-P

Preview Manual d'usuari de l'inversor de càrrega solar tot en un SunGoldPower sèrie SPH
Manual d'usuari complet per als inversors de càrrega solar tot en un SunGoldPower sèrie SPH, que cobreix la instal·lació, el funcionament, el manteniment i les especificacions tècniques dels models SPH8K48SP i SPH10K48SP.
Preview Guia de resolució de problemes del carregador de l'inversor d'ona sinusoidal pura Sungoldpower
Una guia completa de resolució de problemes per als carregadors inversors d'ona sinusoidal pura Sungoldpower, que cobreix problemes comuns com ara lectures anormals de CA, problemes de càrrega de la bateria, fallades de sortida i funcionament del ventilador.
Preview Manual d'usuari de l'inversor/carregador d'ona sinusoidal pura de la sèrie LFP
Manual d'usuari de l'inversor/carregador d'ona sinusoidal pura de la sèrie LFP, que detalla informació de seguretat, introducció, instal·lació, rendiment elèctric, resolució de problemes i especificacions.
Preview Manual d'usuari de l'inversor de càrrega solar tot en un Sungoldpower SPH8K48SP / SPH10K48SP
Manual d'usuari complet per als inversors de càrrega solar tot en un Sungoldpower SPH8K48SP i SPH10K48SP, que cobreix la seguretat, la instal·lació, el funcionament, la comunicació, la resolució de problemes i les especificacions tècniques.
Preview Manual d'usuari de l'inversor de càrrega solar tot en un SunGoldPower SPH302480A
Aquest manual d'usuari proporciona instruccions completes per a l'inversor de càrrega solar híbrid tot en un SunGoldPower SPH302480A, que cobreix la seguretat, la instal·lació, els modes de funcionament, les funcions de la pantalla LCD, altres característiques, els mecanismes de protecció, el manteniment del sistema i paràmetres tècnics detallats.
Preview Manual d'usuari del sistema d'emmagatzematge d'energia SunGoldPower
Manual d'usuari del sistema d'emmagatzematge d'energia (ESS) SunGoldPower, que cobreix la instal·lació, la connexió, el funcionament, el manteniment i les especificacions tècniques dels models SGN7.6K1HB-48 i SGN11.4KHB-48.