The EARU Electric Single Phase Energy Meter (Model EARU-1006) is designed for accurate monitoring of electrical parameters in single-phase 220V, 80A systems. It provides real-time data for voltage (V), current (A), power (W), power factor (PF), frequency (Hz), and kilowatt-hour (kWh) consumption. This device assists in understanding energy usage and identifying potential inefficiencies in your electrical system.

2. Informació de seguretat

  • La instal·lació ha de ser realitzada per un electricista qualificat d'acord amb els codis i les normatives elèctriques locals.
  • Ensure the main power supply is disconnected before installation or maintenance to prevent electric shock.
  • No feu funcionar el dispositiu si sembla que està danyat.
  • This device is designed for indoor use in a dry environment. Avoid exposure to moisture or extreme temperatures.
  • The maximum current rating is 80A. Do not exceed this limit.

3. Producte acabatview

The EARU-1006 energy meter features a clear LCD display that shows various electrical parameters simultaneously. It is designed for DIN rail mounting, allowing for easy integration into standard electrical distribution boards.

EARU Electric Single Phase Energy Meter front view amb pantalla LCD

Figura 1: Frontal view of the EARU Electric Single Phase Energy Meter, showing the LCD display with various electrical readings.

Close-up of EARU Electric Energy Meter LCD display showing readings

Figura 2: Detallada view of the LCD display, illustrating the layout of voltage, current, power, frequency, power factor, and kWh readings.

4. Contingut del paquet

El paquet normalment inclou:

  • 1 x EARU Electric Single Phase Energy Meter (Model EARU-1006)

5. Especificacions

Technical data table for EARU Electric Energy Meter

Figure 3: Technical data table providing detailed specifications of the energy meter.

Especificacions tècniques
ParàmetreValor
MarcaEARU
ModelEARU-1006
VoltageAC110V/220V (230 Volts)
Corrent nominal80A
Freqüència50/60Hz
Precisió de la mesura±1% / Class 1
Consum d'energia<2W
Instal·lacióCarril DIN de 35 mm
Temperatura de treball-10 °C a +55 °C
Temperatura d'emmagatzematge-40 °C a +70 °C
Humitat de treball5% a 95% HR
Tipus de visualitzacióLCD
Max kWh Record999999 kWh
Dimensions del producte10 x 5 x 10 cm
Pes de l'article450 g
Dimensions of EARU Electric Energy Meter in millimeters and inches

Figure 4: Dimensional drawing of the energy meter, showing measurements in both millimeters and inches.

6. Configuració i instal·lació

Important: Assegureu-vos que tota l'alimentació estigui desconnectada abans de continuar amb la instal·lació.

  1. Muntatge: The EARU-1006 is designed for 35mm DIN rail mounting. Snap the meter onto the DIN rail securely within your electrical panel.
  2. Cablejat: Refer to the wiring diagram below for correct connection. This is a single-phase, 2-wire direct connection meter.
    • Connect the Live (L) input wire to the designated 'L In' terminal.
    • Connect the Neutral (N) input wire to the designated 'N In' terminal.
    • Connect the Live (L) output wire to the designated 'L Out' terminal.
    • Connect the Neutral (N) output wire to the designated 'N Out' terminal.
  3. Encès: Once all connections are secure and verified, restore power to the circuit. The LCD display should illuminate and begin showing readings.
Wiring diagram for EARU Electric Single Phase Energy Meter

Figure 5: Wiring diagram illustrating the correct connections for the single-phase energy meter.

7. Instruccions de funcionament

The energy meter operates automatically once powered on. The LCD display continuously cycles through or shows multiple parameters simultaneously.

  • Reading Parameters: The display shows Voltage (V), Current (A), Power (W), Power Factor (PF), Frequency (Hz), and Kilowatt-hour (kWh).
  • kWh Reading: The meter records total kWh consumption. This reading is permanent and accumulates over time.
  • kWh Reset: The meter features a manual reset function for the kWh reading. Consult the device's physical buttons or specific instructions on the meter itself for the reset procedure. Typically, a long press on a designated button (if present) will reset the temporary kWh value. The total kWh value is usually non-resettable.

8. Manteniment

  • Neteja: Feu servir un drap suau i sec per netejar l'exterior del mesurador. No utilitzeu productes de neteja abrasius ni dissolvents.
  • Inspecció: Periodically inspect the wiring connections to ensure they are tight and free from corrosion.
  • Medi ambient: Assegureu-vos que l'entorn de funcionament es mantingui dins dels rangs de temperatura i humitat especificats.

9. Solució De Problemes

ProblemaCausa possibleSolució
La pantalla està en blancSense subministrament d'alimentació; cablejat incorrecteCheck power connections and ensure power is supplied. Verify wiring against the diagram.
Lectures incorrectesIncorrect wiring; Faulty connectionDouble-check all wiring connections. Ensure wires are securely fastened.
kWh not accumulatingNo load connected; Meter malfunctionEnsure there is an active electrical load connected through the meter. If problem persists, contact support.

10. Garantia i Suport

The EARU Electric Single Phase Energy Meter (Model EARU-1006) typically comes with a 1-year warranty from the date of purchase. Please retain your purchase receipt for warranty claims.

For technical support, troubleshooting assistance, or warranty inquiries, please contact your retailer or the manufacturer directly. Refer to the product packaging or manufacturer's weblloc per obtenir dades de contacte.

Documents relacionats - EARU-1006

Preview EARU EAPDX-40/63 Series Adjustable VoltagManual d'usuari del protector de corrent i electròniques
User manual for the EARU EAPDX-40/63 Series Adjustable Voltage & Current Protector, detailing specifications, features, and operation for electrical protection. Includes setup instructions and parameter configuration.
Preview EARU D52-2066 Series Single Phase Multi-functional Energy Meter | Technical Specifications
Detailed technical specifications and wiring instructions for the EARU D52-2066 Series DIN-rail single-phase multi-functional energy meter, measuring AC voltage, current, active power, power factor, frequency, and electric energy.
Preview PC321-Z-TY Cl d'alimentació monofàsica/trifàsicaamp Guia d'inici ràpid
Get started with the EARU PC321-Z-TY Smart Power Clamp. This guide covers installation, configuration, and features for monitoring single/3-phase electricity usage with ZigBee connectivity and the Smart Life app.
Preview EARU-X6/8 Metal LED Indicator Light Instruction Manual
User manual for EARU-X6/8 series Metal LED Indicator Lights, detailing safety instructions, warnings, and product description for reliable status indication in industrial and traffic applications.
Preview EARU Automatic Transfer Switch (ATS) Operating Instruction and Technical Specifications
Comprehensive operating instructions and technical specifications for the EARU Automatic Transfer Switch (ATS) model EAATS-F-CG-80. Covers product overview, working conditions, model breakdown, detailed technical parameters, installation guidelines, maintenance procedures, and wiring diagrams.
Preview EARU EAL-2 Din Rail Circuit Breaker Instruction Manual
Instruction manual for the EARU EAL-2 series din rail circuit breaker, detailing its features, safety instructions, and product parameters for AC 2P 230V 4P 400V A Type RCBO RCCB MCB electronic residual current circuit breakers.