This manual provides essential information for the safe and efficient operation of your ACiQ 20 SEER2 Essentials 9000 BTU Mini Split AC/Heating System. This ductless heat pump system is designed to provide both cooling and heating for spaces approximately 250-400 sq. ft. in size, operating on 208/230V power.

Please read this manual thoroughly before installation, operation, or maintenance. Keep it for future reference.

ACiQ 20 SEER2 Essentials Mini Split System components: indoor unit, outdoor unit, remote control, and smartphone displaying the control app.

Imatge: Més deview of the ACiQ Mini Split System, showing the indoor unit, outdoor condenser, remote control, and a smartphone interface for WiFi control.

2. Informació de seguretat

3. Què s'inclou

Your ACiQ Mini Split System package includes the following components:

Diagram showing all included components of the ACiQ Mini Split System, numbered and labeled.

Image: A visual representation of all items included in the ACiQ Mini Split package, such as the indoor unit, outdoor unit, line set, remote, and various installation accessories.

  1. Indoor Unit (Air Handler)
  2. Unitat exterior (condensador)
  3. Control remot
  4. 16ft Line Set (pre-charged for this length)
  5. Tap de paret
  6. Línies de drenatge
  7. Cables d'alimentació
  8. Maquinari de muntatge (cargols, ancoratges)
  9. Piles AAA (per al comandament a distància)
  10. Manual d'usuari (aquest document)
  11. Additional small parts like rubber feet, plastic wrap, plasticine, and a remote mount.

4. Pautes d'instal·lació

As stated in the safety information, installation of this ACiQ Mini Split System requires a qualified HVAC professional. The following points are general guidelines and not a substitute for professional expertise.

Nota important: The unit comes pre-charged with refrigerant for up to a 25ft line set. If your line set is shorter, a professional will still need to vacuum the lines. If a longer line set is used, additional refrigerant may be required, which must be added by a certified technician.

5. Instruccions de funcionament

5.1 Funcionament del control remot

The remote control allows you to manage all functions of your ACiQ Mini Split System. Insert the provided AAA batteries before first use.

Diagram showing the remote control with icons for various features like I Feel Mode, Sleep Mode, Eco Mode, Mute Mode, Timers, and Turbo Mode.

Image: Remote control features, illustrating icons for I Feel Mode, Sleep Mode, Eco Mode, Mute Mode, Timers, and Turbo Mode.

5.2 WiFi Control (Smart Device App)

Your ACiQ Mini Split System is equipped with built-in WiFi, allowing control via a smart device (iOS or Android) from anywhere. The app is compatible with Amazon Alexa, Google Assistant, and IFTTT.

A person smiling while using a smartphone to control the ACiQ Mini Split system via the Smart Life app, demonstrating WiFi control.

Image: A user operating the ACiQ system remotely via a smartphone app, highlighting the WiFi control feature.

  1. Descarregar l'aplicació: Download the "Smart Life" app from your device's app store (iOS or Android).
  2. Registra't/Inici de sessió: Crea un compte o inicia la sessió a l'aplicació Smart Life.
  3. Afegeix un dispositiu: Follow the in-app instructions to add your ACiQ Mini Split System. This typically involves putting the unit into pairing mode (refer to the full manual for specific steps) and connecting it to your home WiFi network.
  4. Control: Once connected, you can control all functions of the unit, including mode, temperature, fan speed, and scheduling, from your smartphone or tablet.
  5. Integració de la llar intel·ligent: Link the Smart Life app with Amazon Alexa, Google Assistant, or IFTTT for voice control and advanced automation.

6. Manteniment

Regular maintenance ensures optimal performance and longevity of your ACiQ Mini Split System. Always disconnect power to the unit before performing any maintenance.

7. Solució De Problemes

Abans de contactar amb l'atenció al client, consulteu els següents problemes i solucions habituals.

ProblemaCausa possibleSolució
La unitat no s'encén.No power, remote batteries dead, circuit breaker tripped.Comproveu el subministrament d'alimentació, substituïu les piles del comandament a distància i reinicieu l'interruptor automàtic.
Refrigeració/calefacció insuficient.Dirty air filters, blocked outdoor unit, wrong mode selected, temperature setting incorrect, low refrigerant.Clean air filters, clear outdoor unit, select correct mode, adjust temperature, contact professional for refrigerant check.
Fuga d'aigua de la unitat interior.Blocked drain line, improper installation.Check and clear drain line, contact professional for inspection.
Soroll inusual.Loose parts, fan obstruction, compressor issue.Turn off unit and inspect for obstructions. If noise persists, contact professional.
El comandament a distància no funciona.Dead batteries, obstruction between remote and unit, remote malfunction.Replace batteries, remove obstructions, try resetting the remote.

For issues not listed here or if solutions do not resolve the problem, please contact ACiQ customer support or a qualified HVAC technician.

8. Especificacions

Diagram showing the dimensions of the indoor and outdoor units, along with key specifications like power supply, cooling/heating BTU, SEER2/EER, estimated coverage area, and indoor noise levels.

Image: Technical specifications and dimensions for the ACiQ Mini Split Indoor and Outdoor Units.

CaracterísticaDetall
Número de modelACiQ-K09W-W-HP230B / ACiQ-K09Z-HP230B
Capacitat9,000 BTU (0.75 Ton)
SEER2 Efficiency20.0
Font d'alimentació230V~ / 60Hz / 1Ph
Interval de funcionament de refrigeració5°F to 122°F outdoor temperature
Interval de funcionament de la calefacció-4°F to 86°F outdoor temperature
Àrea de cobertura estimada250-400 peus quadrats
Dimensions de la unitat interior (alçada x amplada x profunditat)7.99" x 31.92" x 11.49"
Dimensions de la unitat exterior (alçada x amplada x profunditat)19.60" x 30.98" x 11.41"
Nivell de soroll interiorTan baix com 28 dBA
Tipus de refrigerantR454B
Característiques especialsBuilt-in WiFi, Ultra-quiet operation, Full installation kit, Heats in -4°F temps

9. Garantia i Suport

ACiQ provides a comprehensive warranty for your peace of mind.

Warranty information graphic showing '6-Year Compressor & 4-Year Parts Warranty' and 'Best in Class Customer Service' with a shield icon.

Image: ACiQ warranty details, indicating 6-year compressor and 4-year parts coverage.

Si us plau, conserveu el comprovant de compra per motius de garantia.

Documents relacionats - ACiQ-K09W-W-HP230B

Preview Manual d'instal·lació i del propietari del controlador d'aire i condensador mini-split ACiQ Essentials
Comprehensive installation and owner's manual for ACiQ Essentials Mini-Split Air Handler and Condenser systems, covering safety precautions, parts identification, remote control operation, installation procedures, test runs, maintenance, and troubleshooting for various models. The manual also includes critical information regarding the servicing of systems using flammable refrigerant R454B, emphasizing safety protocols and regulatory compliance. It is designed for professional installers and end-users to ensure safe and efficient operation of ACiQ mini-split heat pump systems.
Preview Manual de servei del casset de sostre prim ACiQ i del condensador Platinum
Manual de servei per a les unitats de casset de sostre prim ACiQ i condensador Platinum, que detalla la seguretat, la instal·lació, el manteniment i la resolució de problemes per als models SCC i ACIQ-ZPL.
Preview Sistemes de calefacció estàndard ACiQ 9K-24K d'una sola zona: manual d'instal·lació i del propietari
Manual d'instal·lació i del propietari dels sistemes de calefacció estàndard d'una sola zona ACiQ 9K-24K. Aquesta guia detalla la instal·lació, el funcionament, la seguretat i el manteniment dels aparells d'aire condicionat ACiQ, incloent-hi les especificacions del model i la informació sobre el refrigerant R454B.
Preview Manual d'instal·lació del condensador monozona i del controlador d'aire per conductes ocults ACiQ Extreme Heat
Manual d'instal·lació per als sistemes de tractament d'aire de conductes ocults i condensadors de zona única ACiQ Extreme Heat (models ACIQ-09CD-HH-MC a ACIQ-60CD-HH-MC i ACIQ-09ZPL-HP230C a ACIQ-60ZPL-HP230C). Inclou informació de seguretat, passos d'instal·lació i especificacions.
Preview Manual d'instal·lació i del propietari del controlador d'aire de paret ACiQ i del condensador de zona única per a calor extrema
Aquest manual proporciona pautes detallades d'instal·lació, funcionament i seguretat per als controladors d'aire de paret ACiQ i els condensadors de zona única de calor extrema, que cobreixen els models ACIQ-06W-HH-MD fins a ACIQ-24ZPL-HP230C.
Preview ACiQ Essentials Limited Warranty Certificate and Conditions
Details the ACiQ Essentials Limited Warranty, including warranty periods, conditions for coverage, exclusions, and the arbitration process for ACiQ HVAC systems.