Anern FGI-DU4200

Anern FGI-DU4200 Dual VoltagManual d'usuari de l'inversor solar híbrid e

Model: FGI-DU4200

Marca: Anern

1. Introducció

This manual provides essential information for the safe and efficient operation of your Anern FGI-DU4200 Dual Voltage Hybrid Solar Inverter. Please read this manual thoroughly before installation and use, and retain it for future reference. This inverter is designed to provide reliable power for various applications, integrating solar charging, AC utility charging, and inverter output functions.

Anern FGI-DU4200 Dual Voltage Hybrid Solar Inverter front view

Figura 1: Anern FGI-DU4200 Dual Voltage Hybrid Solar Inverter. This image shows the front panel of the inverter, featuring the display screen and control buttons.

2. Instruccions de seguretat

Please observe the following safety precautions to prevent injury and damage to the inverter or connected equipment:

  • La instal·lació ha de ser realitzada per personal qualificat d'acord amb les normes elèctriques locals.
  • Assegureu-vos que tot el cablejat estigui correctament dimensionat i connectat.
  • No desmunteu l'inversor. No hi ha peces a l'interior que l'usuari pugui reparar.
  • Mantingueu l'inversor allunyat de materials inflamables, humitat i llum solar directa.
  • Assegureu-vos que hi hagi una ventilació adequada al voltant de l'inversor per evitar el sobreescalfament.
  • Always disconnect all power sources (solar, battery, utility) before performing any maintenance or wiring.
  • Utilitzeu l'equip de protecció individual (EPI) adequat durant la instal·lació i el manteniment.

3. Producte acabatview i Característiques

The Anern FGI-DU4200 is a versatile hybrid solar inverter designed for both on-grid and off-grid applications. It features automatic dual-voltage operation and a 120A MPPT solar charge controller.

Característiques principals:

  • Automatic Dual-Voltage Operació: Automatically recognizes 12VDC (2300W output) or 24VDC (4200W output) battery systems.
  • High-Efficiency Pure Sine Wave Output: Provides stable 220-230VAC ±5% output (50Hz) with 90% efficiency.
  • Integrated 120A MPPT Solar Charge Controller: Maximizes solar power harvesting.
  • Múltiples modes de càrrega: Solar, Solar and Utility, Solar Priority.
  • Múltiples modes de sortida: Solar Priority, Utility Priority, SBU (Solar-Battery-Utility) Mode.
  • Seamless Transfer: Grid/generator transfer time less than 20ms for critical loads.
  • Protecció integral: Protecció contra sobrecàrrega, sobretemperatura i curtcircuit.
  • Compatibilitat de la bateria: Supports 12V/24V Lithium, Lead-Acid, and Gel batteries.
  • Capacitat d'arrencada en fred: Ensures operation in extreme conditions.
  • Monitorització de Wi-Fi: Allows system operation control via mobile phone (requires optional Wi-Fi module).
Anern FGI-DU4200 Inverter Features Overview

Figura 2: Acabatview of key features including frequency range, waveform, charging currents, battery voltage, and protection mechanisms.

Anern FGI-DU4200 Dual Voltage Capacitat

Figura 3: Illustration of the inverter's dual voltage capability, supporting 4.2KW at 24V and 2.3KW at 12V battery systems.

4. Configuració i instal·lació

4.1 Desembalatge i inspecció

Upon receiving the inverter, carefully unpack it and inspect for any shipping damage. Ensure all components listed in the packing list are present. If any damage or missing parts are found, contact your dealer immediately.

4.2 Muntatge de l'inversor

Mount the inverter vertically on a sturdy wall or surface. Ensure there is sufficient clearance around the unit for proper ventilation (at least 20 cm on all sides). Avoid mounting in direct sunlight, near heat sources, or in areas with excessive dust or moisture.

4.3 Connexions de cablejat

All wiring must comply with local electrical codes. Use appropriate wire gauges for all connections to prevent overheating and ensure efficient power transfer.

4.3.1 Connexió de la bateria

The inverter supports both 12VDC and 24VDC battery systems. The inverter automatically detects the battery voltage. Ensure correct polarity when connecting batteries. For 12V systems, batteries are typically connected in parallel. For 24V systems, batteries are typically connected in series.

Battery Connection Diagram for 12V Parallel and 24V Series

Figura 4: Wiring diagram illustrating parallel connection for 12V battery systems (2300W output) and series connection for 24V battery systems (4200W output).

Compatible Battery Types for Anern FGI-DU4200 Inverter

Figura 5: The inverter is compatible with various battery types, including Gel, AGM, Flooded (FLD), Lithium (LI), and Sealed Lead-Acid (SLD) batteries.

4.3.2 Connexió del panell solar

Connect your solar panels to the designated PV input terminals. Ensure the open circuit voltage (Voc) of your solar array does not exceed the inverter's maximum PV input voltage (500Vdc). Observe correct polarity.

4.3.3 AC Input Connection (Utility/Generator)

Connect the AC utility grid or a compatible generator to the AC input terminals. The inverter supports 220-230VAC input. Ensure proper grounding.

4.3.4 AC Output Connection (Loads)

Connect your household or office loads to the AC output terminals. The inverter provides a pure sine wave output suitable for sensitive electronics. Do not exceed the rated output power of the inverter (2300W for 12VDC systems, 4200W for 24VDC systems).

Anern FGI-DU4200 System Diagram

Figura 6: Comprehensive system diagram showing connections for solar panels, generator/utility, external battery packs, and various home appliances.

Anern FGI-DU4200 Inverter Outdoor Installation Example

Figura 7: Example of an outdoor installation of the Anern FGI-DU4200 inverter, demonstrating its integration into a home solar power system.

5. Instruccions de funcionament

5.1 Engegada/apagada

After all connections are securely made, switch on the battery breaker first, then the solar array breaker, and finally the AC input breaker (if connected). Press the power button on the inverter to turn it on. To power off, reverse the sequence: turn off AC input, then solar, then battery, and finally the inverter power button.

Pantalla LCD 5.2 i botons de control

The inverter features an LCD display that shows real-time operating status, input/output voltages, battery status, and error codes. Use the control buttons (ESC, UP, DOWN, ENTER) to navigate through menus and adjust settings.

5.3 modes de càrrega

The inverter offers four selectable charging modes:

  • Prioritat solar: Solar power charges the battery first. If solar is insufficient, utility power supplements.
  • Prioritat d'utilitat: Utility power charges the battery first. Solar power supplements if utility is unavailable.
  • Només solar: Only solar power charges the battery.
  • Solar i serveis públics: Both solar and utility power charge the battery simultaneously.

5.4 Modes de sortida

The inverter offers three selectable output modes:

  • Prioritat d'utilitat: Loads are primarily powered by utility. If utility fails, the inverter switches to battery power.
  • Prioritat solar: Loads are primarily powered by solar. If solar is insufficient, battery power is used. If both are insufficient, utility power is used (if connected).
  • SBU (Solar-Battery-Utility) Mode: Loads are powered by solar first, then battery, and finally utility if both solar and battery are depleted or unavailable.

5.5 Wi-Fi Monitoring (Optional)

If equipped with the optional Wi-Fi module, the inverter can be monitored and controlled via a mobile application. Connect the Wi-Fi module to the designated port on the inverter and follow the instructions provided with the module for setup.

Wi-Fi Monitoring Setup for Anern FGI-DU4200 Inverter

Figura 8: Diagram illustrating the connection of an optional Wi-Fi module for remote monitoring and control of the inverter system via a mobile application or web interfície.

6. Manteniment

Un manteniment regular garanteix la longevitat i el rendiment òptim del vostre inversor.

  • Neteja: Periodically clean the inverter's exterior with a dry cloth. Ensure ventilation openings are free from dust and debris.
  • Connexions: Annually check all electrical connections for tightness and corrosion. Re-tighten if necessary.
  • Inspecció de la bateria: For lead-acid batteries, check electrolyte levels and terminal condition as per battery manufacturer guidelines.
  • Medi ambient: Assegureu-vos que l'entorn de funcionament es mantingui dins dels rangs de temperatura i humitat especificats.

7. Solució De Problemes

This section provides solutions to common issues. For problems not listed here, contact technical support.

ProblemaCausa possibleSolució
L'inversor no s'encénNo hi ha connexió de bateria; Volum de la bateriatage too low; Power button not pressed.Comproveu les connexions de la bateria i el voltage; Charge battery; Press and hold power button.
Sense sortida de CAOverload; Short circuit; Battery low; Inverter fault.Reduce load; Check for short circuits; Charge battery; Restart inverter.
La càrrega solar no funcionaSolar panels disconnected; Insufficient sunlight; PV voltage too low/high; MPPT fault.Check PV connections; Ensure adequate sunlight; Verify PV voltage dins del rang.
Es mostra el codi d'errorSpecific fault detected by the inverter.Refer to the inverter's LCD display for the specific error code and consult the full manual (if available) or contact support for detailed interpretation and resolution.

8. Especificacions

ParàmetreValor
ModelFGI-DU4200
Rated Power (12VDC)2300W
Rated Power (24VDC)4200W
Voltage12VDC / 24VDC (Auto-sensing)
Vol. De sortidatage220-230VAC ±5% (50Hz)
Forma d'onaOnda senyal pura
Controlador de càrrega solar MPPT de corrent120A
Volum màxim de circuit obert de matriu fotovoltaicatage500Vdc
Corrent de càrrega de CA60A
Eficiència90%
Temps de transferència<20 ms
Dimensions del producte16.9 x 8.27 x 21.6 polzades
Pes de l'article19.14 lliures
FabricantAnern

9. Garantia i Suport

Anern products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official Anern website. For technical support, troubleshooting assistance, or spare parts, please contact Anern customer service through their official channels. Please have your model number (FGI-DU4200) and purchase date ready when contacting support.

Informació de contacte: Refer to your product packaging or the official Anern weblloc web per obtenir les dades de contacte més actualitzades.

Documents relacionats - FGI-DU4200

Preview ANERN FGI-S12000 Hybrid Solar Inverter User Manual
User manual for the ANERN FGI-S12000 Hybrid Solar Inverter. This guide details the installation, operation, safety, and specifications of the 12KW solar energy storage system, featuring MPPT charge control and UPS functionality.
Preview ANERN FGI-P6500 MPPT Solar Inverter User Manual
Explore the ANERN FGI-P6500 MPPT Solar Inverter with this comprehensive user manual. Learn about installation, operation, safety, and troubleshooting for your solar energy storage system.
Preview Anern MPPT Solar Inverter Product Manual: AN-FGI-AS12000 & AN-FGI-AS12000P
Comprehensive product manual for Anern AN-FGI-AS12000 and AN-FGI-AS12000P MPPT solar inverters. Covers installation, operation, safety, troubleshooting, and technical specifications for efficient solar energy management.
Preview Anern AN-FGI-AS7200/AS7200P MPPT Solar Inverter Product Manual | Installation & Operation Guide
Comprehensive product manual for Anern AN-FGI-AS7200 and AN-FGI-AS7200P MPPT Solar Inverters. Learn about installation, operation, features, safety, and technical specifications for hybrid solar energy systems.
Preview Manual d'usuari de l'inversor híbrid d'ona sinusoidal pura d'Anern: Guia d'instal·lació, seguretat i funcionament
This user manual provides comprehensive safety, installation, and operation guidelines for the Anern Pure Sine Wave Hybrid Inverter. It covers essential information on tools, wiring, and system setup for reliable power solutions.
Preview Anern FGI-S4000 MPPT Solar Inverter User Manual
User manual for the Anern FGI-S4000 MPPT Solar Inverter, detailing installation, operation, safety, and troubleshooting for solar energy storage systems.