GEYA G2R 2P 63A AC110V Automatic Transfer Switch Instruction Manual

Introducció

This manual provides essential information for the safe and effective installation, operation, and maintenance of your GEYA G2R 2P 63A AC110V Automatic Transfer Switch. Please read this manual thoroughly before installation and use, and retain it for future reference.

Informació de seguretat

ADVERTIMENT: Electrical shock hazard. Installation and servicing must be performed by qualified personnel only. Disconnect all power sources before working on the switch.

Producte acabatview

The GEYA G2R Automatic Transfer Switch (ATS) is designed to ensure an uninterruptible power supply by automatically switching between a main power source and a backup power source. It features both automatic and manual operation modes and is suitable for DIN rail mounting.

Característiques principals:

Dimensions del producte:

GEYA G2R Automatic Transfer Switch dimensions, showing front and side views amb mesures en mil·límetres.

Imatge: Frontal i lateral views of the GEYA G2R Automatic Transfer Switch with detailed dimensions in millimeters. The unit measures 108mm in height, 50.5mm in width (2P version), and 70mm in depth.

Configuració i instal·lació

The GEYA G2R ATS supports both DIN rail mounting and screw mounting for flexible installation. Ensure the mounting location is dry, well-ventilated, and free from excessive vibration.

Instruccions de cablejat:

Refer to the wiring diagram below for correct connection. It is crucial that the input power supply is connected in the correct phase sequence.

Wiring diagram for GEYA G2R Automatic Transfer Switch, showing connections for main and backup power supplies, load, and neutral wires.

Image: Detailed wiring diagram for the GEYA G2R ATS. It illustrates connections for backup power neutral wire (1), common power neutral wire (2), common power supply (3), backup power supply (4), load power (5), load output neutral wire (6), DIN-Rail buckle (7), backup power live wire (8), common power live wire (9), closing indication (10), manual operation handle (11), and load output live wire (12). A note emphasizes correct phase sequence for input power.

Voltage Selecció:

Seleccioneu el vol adequattage model for your system. This model is designed for AC 110V systems. Using an incorrect voltage can damage the control circuit.

Voltage selection guide for GEYA G2R ATS, showing 2P 63A 220V and 2P 63A 110V models.

Image: Voltage selection guide for GEYA G2R ATS. It shows two configurations: G2R-2P-63A-220V for 220/400V systems or one L line 220V, and G2R-2P-63A-110V for 110/220V systems or one L line 110V. A warning advises choosing the correct voltage to prevent coil damage.

Instruccions de funcionament

Modes de funcionament:

Estat de la llum indicadora:

Vídeo de demostració de l'operació:

Video: This video demonstrates the operation of the GEYA ATS, showing how to switch between manual and automatic modes, and how the device automatically transfers power when the main supply is interrupted or restored. It illustrates the indicator light behavior during different power states.

Manteniment

The GEYA G2R ATS is designed for durability with a mechanical life of ≥8000 times and an electrical life of ≥1500 times. Regular maintenance is minimal but important for optimal performance.

Resolució de problemes

ProblemaCausa possibleSolució
Switch does not transfer automatically.Incorrect mode selection (manual instead of auto).
Font d'alimentació defectuosa.
Control circuit issue.
Ensure the switch is set to "Auto" mode.
Check both main and backup power sources.
Consult qualified electrician.
Els indicadors lluminosos no funcionen.Sense energia a la unitat.
Mal funcionament del LED.
Verify power supply connections.
Contact support if power is present but lights are off.
Overvoltage/Undervoltage indication (flashing light).Vol d’entradatage outside normal operating range.Check the stability of your power sources. The unit will automatically recover after 30 seconds if voltage torna a la normalitat.

Especificacions

ParàmetreValor
Corrent nominal63A
Aïllament nominal Voltage690 V
Voltage110 V CA
Freqüència nominal50/60Hz
Rated Short-Circuit Current5KA
Vida mecànica≥8000 vegades
Vida elèctrica≥1500 vegades
Grau ignífug94V-2
Tipus de muntatgeMuntatge sobre carril DIN
Nombre de pols2
Número de model de l'articleIG-G2R-2P-63A-AC110V
Dimensions del paquet4.84 x 3.43 x 2.2 polzades; 13.44 unces

Garantia i Suport

Per obtenir informació sobre la garantia o assistència tècnica, consulteu el lloc web oficial del fabricant. website or contact your point of purchase. Keep your purchase receipt for warranty claims.

Manufacturer: GEYA

Per obtenir més ajuda, visiteu el GEYA Store on Amazon.

Documents relacionats - G2R 2P 63A AC110V

Preview Commutador de transferència automàtica (ATS) GEYA G2R-63/00 - Especificacions tècniques
Especificacions tècniques detallades i guia d'instal·lació per al commutador de transferència automàtica (ATS) GEYA G2R-63/00, que inclou commutació de classe PC per a fonts d'alimentació duals, condicions de funcionament i procediments de manteniment.
Preview Manual del commutador de transferència automàtica dual de commutació ininterrompuda de mil·lisegons de Zhejiang Geya Electrical
Aquest manual proporciona informació detallada sobre el commutador de transferència automàtica dual de commutació ininterrompuda de mil·lisegons de Zhejiang Geya Electrical Co., Ltd., incloent-hi informació general, paràmetres tècnics, instal·lació, cablejat, manteniment i precaucions de seguretat.
Preview GEYA Smart Power Protection Product Catalogue
Comprehensive catalogue of GEYA's over/under voltage and current protectors, automatic transfer switches, and energy metering devices, featuring technical specifications, features, and installation guidance for various models.
Preview GEYA WiFi Din Rail Switch Operating Manual & Configuration Guide
Operating manual for the GEYA WiFi Din Rail Switch (models GWS10-Z, GWS10-W1, GWS10-W). This guide details features like remote control, timing, voice control, and real-time electricity monitoring. It provides step-by-step instructions for setup and configuration using the Smart Life APP, including LED indicator descriptions and live view capabilities for energy management. Suitable for smart home and electrical automation.
Preview Interruptor miniatura intel·ligent de la sèrie GEYA WiFi: instruccions d'ús
Instruccions d'ús detallades i preguntes freqüents per a l'interruptor miniatura intel·ligent de la sèrie GEYA WiFi (sèrie ZJSB9). Apreneu sobre la instal·lació, la configuració, la resolució de problemes, la seguretat i l'aplicació per a la protecció elèctrica de la llar intel·ligent.
Preview Manual d'instruccions del relé de control de temperatura GEYA GRW8
Manual d'instruccions per als relés de control de temperatura i control de rang de temperatura de la sèrie GEYA GRW8. Les característiques inclouen alimentació universal, indicació d'estat per LED i muntatge en carril DIN. Cobreix aplicacions, característiques funcionals, paràmetres tècnics, diagrames de panells, diagrames de cablejat i dimensions.