1. Introducció
The Pecron U20 Universal Cable Kit is designed to provide versatile connectivity for various power needs, including portable power stations, solar panels, car accessories, and drones. This kit features 17 different XT60 adapter cables and two types of Z30 hubs, one with a real-time monitoring display, ensuring compatibility and efficient power management.
2. Producte acabatview
2.1 Components del kit
The U20 Universal Cable Kit includes a comprehensive set of cables and hubs, all organized within a durable accessory pouch.
- 17 XT60-F Adapter Cables: 16 cables are 500mm (19.7in) long, and 1 cable is 2000mm (78.7in) long. These include adapters for MC4, XT60-F, XT60-M, GX16-5 Female, GX16-5 Male, DC5525 Female & DC5521 Female, DC5525 Male & DC5521 Male, DC8020 Female & DC7909 Female, DC8020 Male & DC7909 Male, 30A, M8 Lug Terminal, XT90H Female, XT90 Male, Cigarette Lighter Plug, Cigarette Lighter Socket, and Alligator Clip.
- 3 Z30 Hubs: Basic adapters for connection.
- 1 Z30 Monitor Hub: Features a display for real-time monitoring of input/output voltage, current, power, energy statistics, and current direction.
- Accessory Pouch: Double-layer design for organized storage.
2.2 Especificacions del cable
- Material: Premium materials for excellent conductivity and high-temperature resistance.
- Calibres de filferro: Includes 12AWG for high-current tasks, and 14AWG/16AWG for standard uses (e.g., car outlets, LED lights).
2.3 Z30 Monitor Hub Features
- Monitorització en temps real: Displays input/output voltage, current, power, energy statistics, and current direction.
- Mesura precisa: Helps users precisely monitor device power status.
- Codis d'alarma: Indicates Overvoltage (IOVA) and Overcurrent (IOVA).
3. Instruccions de seguretat
- Always ensure proper polarity when connecting cables to avoid damage to devices or the cable kit.
- Do not exceed the maximum current or voltage ratings of any cable or hub.
- Keep the cable kit dry and away from extreme temperatures unless specified for outdoor use with appropriate protection.
- Inspect cables and connectors for any damage before each use. Do not use damaged components.
- Store the kit in its accessory pouch to prevent tangling and damage.
4. Configuració
4.1 Desempaquetar el kit
Carefully open the accessory pouch and identify all components. The double-layer design ensures each cable and connector has its independent space.

Image: The Pecron U20 Universal Cable Kit neatly organized within its gray and orange accessory pouch, showcasing the compact and portable design.

Image: The open Pecron U20 Universal Cable Kit, revealing various adapter cables and hubs securely stored in mesh pockets within the double-layered case.
4.2 Identifying Cables and Hubs
Refer to the labels on each cable and hub to match them with your specific device requirements. The kit includes a variety of connectors for different applications.

Imatge: Una imatge detallada view of various XT60-F adapter cables and the Z30 Hub and Z30 Monitor Hub, illustrating the different connector types included in the kit.
5. Instruccions de funcionament
5.1 Connecting to a Power Station (Basic Hub)
To connect two power stations or a power station to another device using a Z30 Hub:
- Select the appropriate XT60-F adapter cable for your power station's input/output port.
- Connect one end of the adapter cable to the power station.
- Connect the other end of the adapter cable to the Z30 Hub.
- Connect a second adapter cable from the Z30 Hub to the target device (e.g., another power station).

Image: A diagram illustrating how to connect two power stations using an XT60-F adapter cable and a Z30 Hub for power transfer.
5.2 Connecting with Z30 Monitor Hub (Monitoring Power Flow)
For real-time monitoring of power flow between devices, use the Z30 Monitor Hub:
- Select the correct XT60-F adapter cable for your power source (e.g., battery, solar panel).
- Connect the adapter cable from the power source to one side of the Z30 Monitor Hub.
- Connect another adapter cable from the other side of the Z30 Monitor Hub to your power station or device.
- Observe the display on the Z30 Monitor Hub for real-time voltage, current, power, and energy statistics.

Image: A diagram showing a battery connected to a Z30 Monitor Hub, which then connects to a power station, allowing for real-time power monitoring.

Image: Close-up of the Z30 Monitor Hub display, detailing readouts for input voltage, operating current, operating power, current direction, energy consumption, operating time, and alarm codes like Overvoltage (IOVA) and Overcurrent (IOVA).
5.3 Solar Panel Connections
The kit includes MC4 adapter cables for connecting to solar panels:
- Connect the XT60-F to MC4 Adapter Cable to your solar panel's output.
- Connect the XT60-F end of the cable to the appropriate input port on your power station or Z30 Hub.

Image: A diagram illustrating how to connect solar panels to a power station using an XT60-F to MC4 adapter cable.
Video: This video demonstrates the advantages of Bateria Power solar panel cables, highlighting their protective sleeving, flame-retardant material, 10AWG tinned copper wire, IP68 protection, and ease of use with solar connectors and caps. It also shows a wide application for RVs, roofs, boats, and auto vehicles solar power systems.
7. Manteniment
- Neteja: Use a dry, soft cloth to clean cables and hubs. Avoid using harsh chemicals or abrasive materials.
- Emmagatzematge: Store the kit in a cool, dry place, ideally in its original accessory pouch, to protect components from dust and physical damage.
- Inspecció: Regularly check all cables and connectors for signs of wear, fraying, or corrosion. Replace any damaged components immediately.
8. Solució De Problemes
8.1 No Power Output/Input
- Comproveu les connexions: Ensure all cables are securely connected to both the power source/device and the hub.
- Verifica la polaritat: Confirm that positive and negative terminals are correctly matched. Incorrect polarity can prevent operation or cause damage.
- Inspeccionar els cables: Look for any visible damage to cables or connectors.
- Z30 Monitor Hub: If using the monitor hub, check for any alarm codes (e.g., IOVA for overvoltage/overcurrent) that might indicate an issue.
8.2 Inaccurate Readings on Z30 Monitor Hub
- Recalibrar: If readings appear inaccurate, disconnect and reconnect the hub to reset it.
- Factors ambientals: Extreme temperatures can sometimes affect electronic readings. Ensure the hub is operating within its specified temperature range.
9. Especificacions
| Component | Descripció |
|---|---|
| Model | U20 Universal Cable Kit |
| Quantitat de cable | 17 (16x 500mm/19.7in, 1x 2000mm/78.7in) |
| Hub Quantity | 4 (3x Z30 Hub, 1x Z30 Monitor Hub) |
| Interfícies suportades | XT60, MC4, DC5525, DC5521, DC8020, DC7909, 30A, M8 Lug Terminal, XT90, Cigarette Lighter, Alligator Clips, GX16-5 |
| Calibres de filferro | 12AWG, 14AWG, 16AWG |
| Dimensions del producte | 10.9 x 7.9 x 4 polzades |
| Fabricant | pecron |
10. Garantia i Suport
For warranty information and customer support, please refer to the official Pecron website or contact your retailer. Ensure you retain your proof of purchase for any warranty claims.