HAKINAKU HD18

HAKINAKU HD18 Carbon Monoxide and Combustible Gas Detector

Manual d'usuari

1. Introducció

The HAKINAKU HD18 is a plug-in 5-in-1 detector designed to monitor your environment for carbon monoxide (CO) and combustible gases. It also provides real-time readings for temperature and humidity, and features a built-in backup battery for continuous operation during power outages. This device offers enhanced home safety by integrating multiple detection capabilities into a single unit.

HAKINAKU HD18-CG detector plugged into an outlet, with a family in the background, illustrating its 10+ year lifespan and home safety benefits.

Image: HAKINAKU HD18-CG detector plugged into an outlet, with a family in the background, illustrating its 10+ year lifespan and home safety benefits.

2. Informació de seguretat

Please read all instructions carefully before installation and use. Failure to follow these instructions may result in property damage, injury, or death.

  • This device is intended for residential use.
  • Do not paint the detector. Paint can clog the sensor openings and prevent the unit from functioning properly.
  • Do not block the ventilation openings on the detector.
  • Test the detector weekly to ensure proper operation.
  • The detector should be installed in a location where the alarm can be heard by all occupants.
  • Monòxid de carboni (CO) is an odorless, colorless, and poisonous gas. This detector is designed to alert you to the presence of CO.
  • Gasos combustibles (such as natural gas, propane, methane) are flammable and can cause explosions. This detector is designed to alert you to their presence.
  • This device is not a substitute for proper installation, use, and maintenance of fuel-burning appliances, including appropriate ventilation and exhaust systems.

3. Característiques del producte

  • Detecció 5 en 1: Integrates carbon monoxide, combustible gas, temperature, humidity sensors, and a backup battery.
  • Disseny de connectors: Compatible with 110V to 240V AC outlets for easy installation.
  • Built-in 1000mAh Backup Battery: Provides approximately 12 hours of operation during power outages. Rechargeable lithium battery design eliminates the need for disposable battery replacements.
  • Pantalla HD de 2.1 polzades: Displays real-time data including CO ppm, combustible gas warning icon, humidity, temperature, CO indicator, plug status, and alarm status.
  • Alertes sonores i visuals: Features an 85 dB alarm sound and dynamic data display on the HD screen for effective alerts.
  • Opcions de càrrega dual: Supports both plug-in charging and Type-C USB charging (cable not included). This allows for portable use.
Close-up of the HAKINAKU HD18-CG detector's screen, highlighting its five independent sensors: carbon monoxide, combustible gas, humidity, temperature, and backup battery.

Image: Close-up of the HAKINAKU HD18-CG detector's screen, highlighting its five independent sensors: carbon monoxide, combustible gas, humidity, temperature, and backup battery.

Illustration showing the HAKINAKU HD18-CG detector plugged into an outlet next to a graphic of a 1000mAh battery, emphasizing its built-in backup battery and charging features.

Image: Illustration showing the HAKINAKU HD18-CG detector plugged into an outlet next to a graphic of a 1000mAh battery, emphasizing its built-in backup battery and charging features.

4. Contingut del paquet

Verifiqueu que tots els elements estiguin inclosos al vostre paquet:

  • 1 x HAKINAKU HD18 4-in-1 CO & Gas Detector
  • 1 x Manual d'usuari

5. Configuració

The HAKINAKU HD18 detector is designed for simple plug-and-play operation.

  1. Trieu una ubicació: Select an AC outlet in areas such as bedrooms, kitchens, living rooms, or basements. For optimal CO detection, place the detector at chest height. For combustible gas, place it closer to the floor if the gas is heavier than air (e.g., propane) or closer to the ceiling if lighter than air (e.g., natural gas). Avoid placing near windows, doors, or ventilation openings that could interfere with readings.
  2. Connectar: Insert the detector into a standard 110V to 240V AC outlet.
  3. Calibració: The detector will automatically begin a self-calibration process upon first power-up. This typically takes a few minutes. During this time, the screen may display a countdown or initialization sequence.
  4. A punt per al seu ús: Once calibration is complete, the screen will display real-time CO ppm, gas status, temperature, and humidity readings, indicating the device is operational.

6. Instruccions de funcionament

6.1. HD Screen Display Overview

The 2.1-inch HD screen provides a clear, real-time view of environmental data and device status.

Detailed diagram of the HAKINAKU HD18-CG detector's HD screen display, labeling all icons and buttons including power, screen brightness, buzzer, test, CO ppm, gas icon, temperature, and humidity.

Image: Detailed diagram of the HAKINAKU HD18-CG detector's HD screen display, labeling all icons and buttons including power, screen brightness, buzzer, test, CO ppm, gas icon, temperature, and humidity.

  • CO PPM: Displays the current carbon monoxide concentration in parts per million.
  • GAS Icon: Indicates the presence and concentration level of combustible gas.
  • Temperatura: Mostra la temperatura ambient.
  • Humitat: Shows the ambient humidity level.
  • Nivell de bateria: Indicates the charge status of the built-in backup battery.
  • Plug Icon: Indicates if the device is connected to AC power.
  • Estat d'alarma: Visual indicators for CO and gas alarms.

6.2. Funcions del botó

  • Botó d'encesa:
    • Short press: Turns the device on or off.
  • Botó de brillantor de la pantalla:
    • Short press: Changes the screen brightness.
    • Long press: Changes the temperature unit (Celsius/Fahrenheit).
  • Botó de brunzidor:
    • Short press: Turns the buzzer (audible alarm) on or off.
    • Long press: Rotates the screen display (0, 90, 180, or 270 degrees).
  • TEST Button (Self-test):
    • Short press: Initiates a self-test of the device, including the alarm sound and display.

6.3. Funcions d'alarma

The detector provides distinct audible and visual alarms for carbon monoxide and combustible gas.

Alarma de monòxid de carboni (CO):
  • 0-50 ppm: No alarm. The carbon monoxide icon remains green.
  • 51-200 ppm: The device sounds an audible alarm every 3 minutes. The carbon monoxide icon turns yellow and blinks.
  • 201-999 ppm: The device sounds continuous audible alarms. The carbon monoxide icon turns red and blinks.
Combustible Gas Alarm:
  • No Combustible Gas: No alarm. The combustible gas icon remains green.
  • Low and Medium Concentrations: The device sounds an audible alarm every 3 minutes. The combustible gas icon turns yellow and blinks.
  • High Concentrations: The device sounds continuous audible alarms. The combustible gas icon turns red and blinks.

6.4. Informació de la bateria

The HD18 features a built-in 1000mAh rechargeable lithium-ion battery.

  • The battery provides approximately 12 hours of emergency operation during power outages.
  • The battery automatically recharges when the device is plugged into an AC outlet.
  • For portable use, the device can also be charged via a Type-C USB cable (not included).

7. Manteniment

Regular maintenance ensures the detector operates effectively.

  • Prova setmanal: Press the TEST button weekly to verify the alarm sound and display functionality.
  • Neteja: Gently clean the exterior of the detector with a soft, damp cloth. Do not use cleaning agents, solvents, or harsh chemicals. Avoid spraying cleaners directly onto the unit. Do not block the sensor openings.
  • Comprovació de la bateria: The battery level indicator on the HD screen will show the charge status. Ensure the device is plugged in regularly to keep the backup battery charged.
  • Eviteu les obstruccions: Ensure that nothing obstructs the detector's ventilation openings.

8. Solució De Problemes

If you encounter issues with your HAKINAKU HD18 detector, refer to the following common problems and solutions:

ProblemaCausa possibleSolució
No hi ha pantalla/El dispositiu no s'encénNo connectat; Apagattage; Battery depletedEnsure device is securely plugged into a working outlet. Check household circuit breaker. Allow backup battery to charge.
Alarm sounds intermittently or continuouslyPresence of CO or combustible gas; False alarm; Sensor malfunctionIf CO or gas is suspected: Ventilate the area immediately, evacuate, and call emergency services. Do not re-enter until safe. If no gas is present, test the unit. If alarm persists, contact support.
TEST button does not activate alarmDevice malfunction; Low batteryEnsure device is plugged in and battery is charged. If still unresponsive, the unit may be faulty and needs replacement.
Lectures de temperatura/humitat inexactesPlacement near heat/cold source; Sensor interferenceRelocate the detector away from direct sunlight, vents, or appliances that emit heat or cold.

9. Especificacions

CaracterísticaEspecificació
Número de modelHD18
Font d'alimentacióAC 110V-240V
Bateria de seguretatIó de liti de 1000 mAh (inclosa)
Rang de detecció de CO0-999 ppm
Detecció de gasos combustiblesNatural gas, propane, methane, coal gas, gasoline, hexane, butane, benzene, ethylene oxide, acetylene, LPG, LNG, etc.
Potència de l'alarma>85 dB
MostraPantalla HD de 2.1 polzades
Dimensions3.93 x 1.02 x 2.55 polzades
Pes de l'article3.52 unces
Temperatura de funcionamentRefer to product packaging for specific range
Humitat de funcionamentRefer to product packaging for specific range

10. Garantia i Suport

HAKINAKU products are designed for reliability and performance. For warranty information or technical support, please refer to the product packaging or contact HAKINAKU customer service through their official channels. You can also visit the Botiga HAKINAKU a Amazon per a més informació.

Documents relacionats - HD18

Preview Manual d'usuari del detector de monòxid de carboni HAKINAKU HD09
Manual d'usuari del detector de monòxid de carboni HAKINAKU HD09. Coneix les seves característiques, especificacions, instruccions d'ús i precaucions de seguretat per a un control precís del CO.
Preview Manual d'usuari del detector de monòxid de carboni model D6
Aquest manual d'usuari proporciona instruccions i especificacions per al detector de monòxid de carboni Model D6. Apreneu a fer funcionar el dispositiu, a entendre els indicadors de concentració de CO i a... view especificacions del producte i precaucions de seguretat.
Preview Manual d'usuari del detector de gas radó intel·ligent - Model PT06/PT07 de HAKINAKU
Manual d'usuari del detector de gas radó intel·ligent HAKINAKU (model PT06/PT07). Aprèn sobre la instal·lació, el funcionament, la seguretat, les especificacions tècniques i l'ús de l'aplicació Tuya per controlar els nivells de radó a casa teva.
Preview Guia de l'usuari del monitor intel·ligent de la qualitat de l'aire interior: model PT02-Plus
Guia d'usuari del monitor intel·ligent de qualitat de l'aire interior PT02-Plus, que detalla la configuració, els ajustos manuals, la integració de l'aplicació Tuya i la creació d'escenes intel·ligents per controlar la qualitat de l'aire i els dispositius connectats.
Preview PTH-12 Carbon Monoxide Detector User Manual | Protech International Group
User manual for the PTH-12 Carbon Monoxide Detector by Protech International Group. Provides detailed information on specifications, operation, working principle, indicator lights, warranty, and compliance.