Introducció
This manual provides comprehensive instructions for the diymore LCR-TC1 Multi-Function Transistor Tester. It covers the device's features, proper setup, operational procedures, and maintenance guidelines to ensure accurate and safe use for testing various electronic components.
Informació de seguretat
- No aplicar voltage to the measurement port. This can damage the tester.
- Sempre discharge capacitors completely before testing them with the device. Residual charge can damage the tester or pose a shock hazard.
- The recommended charging input voltage és 4.5 V. Using a higher voltage may permanently damage the tester's internal battery and circuitry.
- Operate the device in a dry environment and avoid exposure to moisture or extreme temperatures.
Producte acabatview
Característiques
- Automatic detection and identification of NPN and PNP transistors, N-channel and P-channel MOSFETs, diodes (including double diodes), thyristors, BJT, resistors, and capacitors.
- Automatic identification of component pinout.
- Built-in lithium battery for portable operation.
- Full-color display for clear parameter readings.
- Integrated IR decoder function for testing infrared remote controls.
Contingut del paquet
El paquet estàndard normalment inclou:
- LCR-TC1 Multi-Function Tester
- Set of test hooks/probes
- Cable de càrrega USB
- Optional: SMD adapter for surface-mount components

Image: The diymore LCR-TC1 Multi-Function Tester shown with its included test hooks and a USB charging cable.
Configuració
Càrrega del dispositiu
The LCR-TC1 features a built-in lithium battery. To charge, connect the provided USB charging cable to the device's charging port and a 4.5V USB power source (e.g., a computer USB port or a compatible USB wall adapter). The indicator light will illuminate green when the battery is fully charged.
Caution: Ensure the charging input voltage does not exceed 4.5V to prevent damage to the tester.
Connexió de sondes de prova
Connect the included test hooks or probes to the designated test points on the ZIF (Zero Insertion Force) socket or directly to the three test pads (labeled 1, 2, 3) for component testing. Ensure secure and proper contact for accurate measurements.
Instruccions de funcionament
Basic Component Testing
- Ensure the device is sufficiently charged and powered on.
- Carefully place the component to be tested into the ZIF socket or connect it using the test hooks to test points 1, 2, and 3. Verify good electrical contact.
- Premeu el botó "Inici".
- The tester will automatically identify the component type (e.g., resistor, capacitor, diode, transistor) and display its measured parameters on the screen.
- For transistors, it will identify NPN/PNP or MOSFET type, determine the pinout (Emitter, Base, Collector or Source, Gate, Drain), and display relevant parameters such as HFE (DC current gain), Vf (forward voltage), and Cgs (gate-source capacitance).
- For resistors, it will display the resistance value.
- For capacitors, it will display capacitance, ESR (Equivalent Series Resistance), and Vpèrdua (voltage pèrdua).
- For diodes, it will display the forward voltage drop and junction capacitance.

Image: The LCR-TC1 tester demonstrating its ability to measure Inductance, Capacitance, Diode characteristics, and Resistance, along with typical measurement ranges.

Image: A transistor connected to the LCR-TC1 using test probes, displaying its type (N-E-MOS) and parameters like Vt, Cgs, i RDG.
IR Decoder Function
The LCR-TC1 includes an IR decoder function. To utilize this, point an infrared remote control towards the IR receiver window on the tester and press any button on the remote. The tester will then display the decoded IR code on its screen, which can be useful for verifying remote control functionality.
Especificacions
- Visualització: Full Color TFT Screen
- Bateria: Bateria de liti incorporada
- Entrada de càrrega: 4.5V DC via USB
- Resistance Measurement Range: 0.01Ω a 50MΩ
- Capacitance Measurement Range: 25pF to 100mF
- Inductance Measurement Range: 0.01mH to 20H
- Supported Component Types: Resistors, Capacitors, Inductors, Diodes (including double diodes), NPN/PNP Transistors, N-channel/P-channel MOSFETs, JFETs, Thyristors, Triacs.
- Funcions addicionals: ESR measurement for capacitors, IR decoder.
Resolució de problemes
"Component Damaged" or "Unknown Component" Error
- Ensure the component is correctly inserted into the ZIF socket or properly connected with test hooks, making good contact.
- Verify that the component is not short-circuited or open-circuited.
- For capacitors, confirm they are fully discharged before testing.
- The component's values might be outside the tester's specified measurement range.
El dispositiu no s'encén
- Check the battery level. Connect the device to a 4.5V USB power source for charging.
- Ensure the power button is pressed firmly and correctly.
Lectures inexactes
- Clean the test probes and ZIF socket contacts to ensure optimal conductivity.
- Ensure stable and secure connections to the component being tested.
- Consider performing a calibration if the device offers such a function (refer to advanced user guides if available).
Manteniment
- Mantingueu el dispositiu net i sec. Feu servir un drap suau i sec per netejar-lo.
- Eviteu exposar el dispositiu a temperatures extremes, humitat elevada o llum solar directa.
- Store the device in a protective case or a safe place when not in use to prevent physical damage.
- Regularly charge the built-in battery to maintain its health, but always adhere to the specified 4.5V charging voltage.
Garantia i Suport
For detailed warranty information, technical assistance, or customer support, please contact diymore customer service. You can typically find contact details on their official website or through the retailer where you purchased the product. When contacting support, please provide your product model (LCR-TC1) and purchase details for efficient service.





