About Fire-Lite manuals on Manuals.plus

Fire-Lite Alarms is a leading manufacturer of non-proprietary fire alarm and life safety control systems. Now part of Honeywell Building Technologies, Fire-Lite offers a broad portfolio of addressable and conventional fire alarm control panels, power supplies, pull stations, and detectors designed for reliability and ease of installation.

Their products are widely used in small to medium-sized commercial, institutional, and industrial applications. Fire-Lite systems are known for their simple setup and open architecture, allowing for flexible maintenance and servicing by authorized dealers. The brand provides comprehensive life safety solutions including emergency communications and mass notification systems.

Manuals de Fire-Lite

Manuals més recents de manuals+ seleccionat per a aquesta marca.

Fire-Lite ANN-80 Series Product Installation Document

guia d'instal·lació
Installation guide for the Fire-Lite ANN-80 Series Remote Fire Annunciators and Indicators, detailing specifications, mounting, wiring, and DIP switch settings for compatible Fire Alarm Control Panels (FACPs).

Fire-Lite manuals from online retailers

Manual d'usuari del detector Fire-Lite 4098-9714

4098 - 9714 • August 19, 2025
The Simplex 4098-9714 is an analog and addressable, replacement, photoelectric smoke detector head. The Simplex 4098-9714 sensor head is designed to provide 360 smoke entry for optimum response…

Fire-Lite support FAQ

Preguntes freqüents sobre manuals, registre i assistència per a aquesta marca.

  • What is the BG-12L pull station?

    The BG-12L is a non-coded, dual-action manual pull station with a key-lock reset feature, designed to provide a manual alarm initiating input to Fire-Lite control panels.

  • Why might smoke detectors fail to alarm during a fire?

    Smoke detectors may not alarm if smoke is prevented from reaching them by closed doors, air vents blowing smoke away, or if the smoke stratifies below the ceiling level.

  • How often should rate-of-rise heat detectors be tested?

    Rate-of-rise heat detectors should be tested at least once per year by a qualified fire protection specialist to ensure they maintain proper sensitivity.

  • What does a battery trouble signal indicate?

    A battery trouble signal on a Fire-Lite panel typically indicates that the standby batteries are disconnected, have low voltage, or need to be replaced.

  • Can Fire-Lite systems protect against loss of life?

    While fire alarm systems provide early warning, they do not guarantee protection against property damage or loss of life, especially if detectors are obstructed or not properly maintained.